• Title/Summary/Keyword: current injection

Search Result 1,048, Processing Time 0.028 seconds

A Study on the Direction of Research for Pharmacopuncture through the Analysis on the Current Status of Chinese Herbal Injections (중약주사제 실태현황 분석을 통한 국내 약침 연구 방향 모색)

  • Hwang, Ji Hye;Choi, Suhyeon;Song, Ho Sueb
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.250-266
    • /
    • 2021
  • Objectives : This study was conducted to suggest new alternative methods to improve pharmacopuncture and Korean medicine research by analyzing the injection route, pharmacological effect, and status studies of Chinese herbal injections. Methods : 130 types of marketed and licensed Chinese herbal injection were searched from National Medical Products Administration (NMPA) of China. CNKI, PubMed, EMBASE, and the 2020 edition of the Chinese Pharmacopoeia were used to collect additional information. 'Herbal injection' and 'Chinese herbal injection' were used as keywords. All data were collected mainly on the treatment of Chinese herbal injection. But data which were not related to the relevant research or Chinese herbal injection were excluded. Results : Intramuscular injection accounted for more than half of the single injection route (51%). Acupoint and intramuscular injections accounted for 55% of dual injection routes. Acupoint, intravenous, and intramuscular injections accounted for the largest proportion (76%) of the multiple routes of injections. As for the pharmacological effect, injection for cardiovascular diseases accounted for 29%. About the number of raw herbal materials, single herbal material was the most common. Twelve intervention studies all tested intravenous injections, and half of them investigated cardiocerebrovascular diseases. All were given by intravenous injection. In the side effect section, the most common symptoms were nausea and vomiting. Conclusions : Through the results, it is expected to be used for research and development of new pharmacopuncture and herbal medicine.

Clinical Experience of Botulinum Toxin-A Injection for the Spasmodic Dysphonia (연축성 발성장애 환자에 대한 Botulinum Toxin-A 주입치료의 임상적 경험)

  • 최홍식;최성희
    • Proceedings of the KSLP Conference
    • /
    • 2002.04a
    • /
    • pp.75-82
    • /
    • 2002
  • Botulinum toxin-A, a neurotoxin derived from Clostridia Botulinum, has been injected into the laryngeal muscle(s) for the treatment of the spasmodic dysphonia at the Voice Clinic, Yonsei Institute of Logopedics and phoniatrics since December 1995. We analyzed 355 patients with spasmodic dysphonia, using Botox register review. In the 355 patients, female is 86.8%. male is 13.2%. 305 patients (85.9%) had adductor type of spasmodic dysphonia and 35 patients (9.9%) were vocal tremor type and 15 patients were abduction and mixed type. Botulinum toxin type-A (Botox) injection using EMG was most frequently conducted as 587 cases, comparing with flexible nasopharyngoscopy gudied injection (68cases) and tele- laryn-goscopy guided injection (31cases). In the respect of frequency of Botox injection, 137 patients(38.6%) were injected one time but 1 patient was injected 17times. The mean dose of Botox is 6.2U. Clinically, initial dose of Botulinum toxin-A was high dose (7-8U) but current dose is small dose (3U). And the mean duration of Botox injection is 6.4 month. In conclusion, to optimize effect of the treatment for spasmodic dysphonia, Botulinum toxin-A injection is combined with voice therapy.

  • PDF

Optimization of Design Variable for Injection Molding Using a Modified Golden Section Search Method (수정된 황금분할 탐색법을 이용한 사출성형 설계인자의 최적화)

  • Park, Jong-Cheon;Kim, Kyung-Mo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 2017
  • The golden section search method is widely used to optimize a single design variable in many fields due to its superior advantages of search. In this paper, a new direct search method is proposed by modifying the search structure of the golden section search method; thus, it can be adapted in the optimization of a single design variable for the injection molding process. This proposed method is applied to determine an optimal gate position for the injection molding of a bezel of an automated teller machine for minimizing the injection pressure. Thus, an optimal gate position where the injection pressure is decreased by 4.5 MPa to that of the initial position was obtained with a small number of simulations. It is anticipated that the current proposed search method can be utilized as a practical tool for optimizing single variables for injection molding design.

Efficiency and Lifetime Improvement of Organic Light- Emitting Diodes with a Use of Lithium-Carbonate- Incorportated Cathode Structure

  • Mok, Rang-Kyun;Kim, Tae-Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.60-63
    • /
    • 2012
  • Enhancement of efficiency and luminance of organic light-emitting diodes was investigated by the introduction of a lithium carbonate ($Li_2CO_3$) electron-injection layer. Electron-injection layer is used in organic light-emitting diodes to inject electrons efficiently between a cathode and an organic layer. A device structure of ITO/TPD (40 nm)/$Alq_3$ (60 nm)/$Li_2CO_3$ (x nm)/Al (100 nm) was manufactured by thermal evaporation, where the thickness of $Li_2CO_3$ layer was varied from 0 to 3.3 nm. Current density-luminance-voltage characteristics of the device were measured and analyzed. When the thickness of $Li_2CO_3$ layer is 0.7 nm, the current efficiency and luminance of the device at 8.0 V are improved by a factor of about 18 and 3,000 compared to the ones without the $Li_2CO_3$ layer, respectively. The enhancement of efficiency and luminance of the device with an insertion of $Li_2CO_3$ electron-injection layer is thought to be due to the lowering of an electron barrier height at the interface region between the cathode and the emissive layer. This is judged from an analysis of current density-voltage characteristics with a Fowler-Nordheim tunneling conduction mechanism model. In a study of lifetime of the device that depends on the thickness of $Li_2CO_3$ layer, the optimum thickness of $Li_2CO_3$ layer was obtained to be 1.1 nm. It is thought that an improvement in the lifetime is due to the prevention of moisture and oxygen by $Li_2CO_3$ layer. Thus, from the efficiency and lifetime of the device, we have obtained the optimum thickness of $Li_2CO_3$ layer to be about 1.0 nm.

Characteristics of Visible Laser Diode and Its Injection-Locking (가시광 다이오드 레이저의 스펙트럼 및 주입-잠금 특성분석)

  • 남병호;박기수;권진혁
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.278-285
    • /
    • 1994
  • We investigated the spectral characteristics for temperature and driving current change in visible laser diode. As a result of spectrum analysis, the ratio of frequency change for temperature and driving current change were about $33 GHz/^{\circ}C$, 6.6 GHz/mA in the region which was not mode hopping range. Compared to the sharp mode hopping in the near IR single mode AlGaAs lasers, the visible laser diode showed relatively broad multimode operation in the mode hopping region. We performed the experiment of injection-locking characteristics analysis for visible laser diode. Locking half bandwidth(LHBW) was measured 0~5.0 GHz for $0~25\muW$ input power and it was dependent on the input power. Also, LHBW for polarization angle was dependent on the difference of polarization angle between master laser and slave laser. The phase change of injection-locked output beam of the slave laser diode as a function of the drive current was measured in the interferometer which was composed of master laser and slave laser. The ratio of phase change with the slope of 5.0~1.3 rad/mA was obtained within injection-locking range for the change of $2~25\muW$ input power. power.

  • PDF

A Study on Injection Attacks and Defenses on Microsoft Windows (MS Windows에서 인젝션 공격 및 방어 기법 연구)

  • Seong, HoJun;Cho, ChangYeon;Lee, HoWoong;Cho, Seong-Je
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.2
    • /
    • pp.9-23
    • /
    • 2020
  • Microsoft's Windows system is widely used as an operating system for the desktops and enterprise servers of companies or organizations, and is a major target of cyber attacks. Microsoft provides various protection technologies and strives for defending the attacks through periodic security patches, however the threats such as DLL injection and process injection still exist. In this paper, we analyze 12 types of injection techniques in Microsoft Windows, and perform injection attack experiments on four application programs. Through the results of the experiments, we identify the risk of injection techniques, and verify the effectiveness of the mitigation technology for defending injection attacks provided by Microsoft. As a result of the experiments, we have found that the current applications are vulnerable to several injection techniques. Finally, we have presented the mitigation techniques for these injection attacks and analyzed their effectiveness.

Increasing injection frequency enhances the survival of injected bone marrow derived mesenchymal stem cells in a critical limb ischemia animal model

  • Kang, Woong Chol;Oh, Pyung Chun;Lee, Kyounghoon;Ahn, Taehoon;Byun, Kyunghee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.6
    • /
    • pp.657-667
    • /
    • 2016
  • Critical limb ischemia (CLI) is one of the most severe forms of peripheral artery diseases, but current treatment strategies do not guarantee complete recovery of vascular blood flow or reduce the risk of mortality. Recently, human bone marrow derived mesenchymal stem cells (MSCs) have been reported to have a paracrine influence on angiogenesis in several ischemic diseases. However, little evidence is available regarding optimal cell doses and injection frequencies. Thus, the authors undertook this study to investigate the effects of cell dose and injection frequency on cell survival and paracrine effects. MSCs were injected at $10^6$ or $10^5$ per injection (high and low doses) either once (single injection) or once in two consecutive weeks (double injection) into ischemic legs. Mice were sacrificed 4 weeks after first injection. Angiogenic effects were confirmed in vitro and in vivo, and M2 macrophage infiltration into ischemic tissues and rates of limb salvage were documented. MSCs were found to induce angiogenesis through a paracrine effect in vitro, and were found to survive in ischemic muscle for up to 4 weeks dependent on cell dose and injection frequency. In addition, double high dose and low dose of MSC injections increased vessel formation, and decreased fibrosis volumes and apoptotic cell numbers, whereas a single high dose did not. Our results showed MSCs protect against ischemic injury in a paracrine manner, and suggest that increasing injection frequency is more important than MSC dosage for the treatment CLI.

Frequency of Lesions on Injection Site by Vaccination Using Needle-Free Injection (무침주사기를 이용한 구제역 백신 접종과 이상육 발생)

  • Lee, S.H.;Choe, J.;Koo, H.J.;Chae, C.J.;Park, J.K.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.23 no.1
    • /
    • pp.27-30
    • /
    • 2021
  • Vaccination for swine food and mouth disease (FMD) has been using needle injection. Needle injection can cause lesions of injection site on muscle and lymph node, leading to consumer's complain and Korea Pork's image deterioration. Needle-free injections have been developing to solve this issues. The current study performed to evaluate the frequency of muscle and lymph node lesions after vaccination using needle-free injection. Needle-free injection significantly decreased the lesions on the injection site compared with the needle injection(36 vs. 16%, p < 0.05). Based on the result, needle-free injection can enhance the quality of pork and decrease consumer's complains. Further study should perform to validate potential of needle-free injection by investigating antibody formation rate, work efficiency, and economic cost.

Numerical Analysis of Three-Dimensional Magnetic Resonance Current Density Imaging (MRCDI) (3차원 자기공명 전류밀도 영상법의 수치적 해석)

  • B.I. Lee;S.H. Oh;E.J. Woo;G. Khang;S.Y. Lee;M.H. Cho;O. Kwon;J.R. Yoon;J.K. Seo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.269-279
    • /
    • 2002
  • When we inject a current into an electrically conducting subject such as a human body, voltage and current density distributions are formed inside the subject. The current density within the subject and injection current in the lead wires generate a magnetic field. This magnetic flux density within the subject distorts phase of spin-echo magnetic resonance images. In Magnetic Resonance Current Density Imaging (MRCDI) technique, we obtain internal magnetic flux density images and produce current density images from $\bigtriangledown{\times}B/\mu_\theta$. This internal information is used in Magnetic Resonance Electrical Impedance Tomography (MREIT) where we try to reconstruct a cross-sectional resistivity image of a subject. This paper describes numerical techniques of computing voltage. current density, and magnetic flux density within a subject due to an injection current. We use the Finite Element Method (FEM) and Biot-Savart law to calculate these variables from three-dimensional models with different internal resistivity distributions. The numerical analysis techniques described in this paper are used in the design of MRCDI experiments and also image reconstruction a1gorithms for MREIT.