• Title/Summary/Keyword: current driving

Search Result 1,383, Processing Time 0.028 seconds

The Control of load Commutated Current Source Inverter for Induction Motor Drive (유도전동기(誘導電動機) 구동(驅動)을 위한 부하전류식(負荷轉流式) 전류형(電流型) 인버터의 제어(制御))

  • Chung, Y.T.;Sim, J.M.;Lee, S.Y.;Soh, Y.C.;Lee, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.255-257
    • /
    • 1994
  • The V/F slip frequency constant control methods are used for driving induction motor with load commutated current source inverter, that is. constant V/F and slip frequency driving is used to load commutate the inverter below the critical frequency, while constant voltage and variable frequency and slip frequency driving are used in above the critical region. In order to applicate the load commutated current source inverter to the general use, speed control range of induction noter is selected to two times at rated frequency. Therefore, economical application is possible because of the maximum reduction of the condenser of the inverter output port. The use of the proposed force commutated circuit improves the false operation of force commutated circuit and inverter commutation failure which are produced by the influence of the lower-order harmonics of the conventional load commutated current source inverter at starting.

  • PDF

Resonance characteristics and electrical properties of PZT-piezoelectric transformer (PZT계 압전변압기의 공진특성과 전기적 성질)

  • 박순태;정수태;이종헌
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.27-34
    • /
    • 1995
  • The analysis of nonlinear equivalent circuit and the resonance characteristics of input current and output voltage were simulated, and their electrical properties are discussed in the transverse-type piezoelectric ceramic transformer. The nonlinear resonance characteristics of input current and output voltage showed by the thermal effect due to a higher driving current, the nonlinearity increased greatly as driving current increased. When load resistor was 100[M.ohm.], the nonlinear coefficient was -1.3. The nonlinear resonance curve of input current and output voltage for a variation of input voltage and load resistor agreed with the discussed theory. The output voltage increased nearly proportioned to input voltage when load resistors were below 50[M.ohm.], the voltage step-up ratio decreased when a load resistor was 100[M.ohm.] and their maximum value was 950.

  • PDF

A Study on the Numerical Model of Wave Induced Current around Nearshore Structure (연안역 구조물 주위에서의 해빈류의 수치해석에 관한 연구)

  • 민병형;이상화;김인철
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.55-63
    • /
    • 1991
  • This study is to predict accurately the wave induced current accuring by the radiation stress which acts as the driving force around Nearshore structure. For the wave induced current, the depth integrated and time averaged governing equation of an unsteady nonlinear form is derived from the continuity and momentum equation of an incompressible fluid. Numerical solutions are obtained by a finite difference method for the governing equation. In the vicinity of a structure, computed flow patterns show good agreement with the hydraulic experimental data. The numerical results obtained by neglecting the convective term show a large change of alongshore and offshore current.

  • PDF

Calculation of Current Unbalance Factor for Induction Motor under the Unbalanced Voltages (불평형 전압 인가시 유도전동기 전류 불평형율 계산)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Eee, Eun-Woong;Jeong, Jong-Ho;Cho, Hyun-Gil;Lee, Jong-Hwan;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.633-634
    • /
    • 2006
  • The current unbalance occurs in an induction motor with the supply of unbalanced voltage. Existence of an current unbalance occurs by various problems at the time of driving by in crease of the noise not to mention output decrease of a motor by increase of a loss. We confirmed how current unbalance occurred by a voltage unbalance because a slip came to change by the driving situation of a subordinate as for the induction motor. We confirmed that case to run to a low slip in a ratio of the same voltage unbalance rate brought a high current unbalance rate.

  • PDF

Current Driving Type Surge Counter (전류구동형 서지카운터)

  • Lee, B.H.;Ahn, C.H.;Chang, S.H.;Jeong, K.M.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1712-1714
    • /
    • 1997
  • This paper deals with the surge counter drived by lightning and switching currents. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. In this paper, for the purpose of protecting the electronic circuits and counting the occuring frequency, the current driving type surge counter is designed and fabricated. The surge counter consists of surge protective divices, current detector, metal oxide varistor(MOV), rectifier, capacitor, and electromagnetic counter. This surge counter is able to count the occuring frequency of surges and to clamp lightning surge current. To evaluate the performance of the surge counter, impulse voltage and current were applied at the surge counter by the surge generator. As a result, applied surges were exactly counted and clamped.

  • PDF

The Reduction Method of Strings Current Unbalancing in LED Lighting Driving System (LED 조명용 구동장치에서 열간 전류의 불평형 감소방법)

  • Park, Chong-Yeun;Song, Jae-Wook;Yoo, Jin-Wan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.26-32
    • /
    • 2013
  • The LED has the proportional characteristic between the flux of light and its current and has caused voltage-current deviation on production process. Thus the unbalancing of each LED strings current occurred by its characteristic deviation. This unbalancing reduce a uniformity of the flux of light. Therefore, we researched to design method the LED driver based on DSP and the balancing transformer for a LED current balancing. These are applied to 50W LED module consist of 4 parallel strings. We analyzed the reduction of LED currents unbalance by experimental result from each method.

Design of a New Op-Amp for Driving Large-Size LCD Panels (대면적 LCD 패널 구동을 위한 새로운 Op-Amp설계)

  • 이동욱;권오경
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.133-136
    • /
    • 2000
  • A new Op-Amp output buffer is presented for driving large-size LCD panels. The proposed Op-Amp is designed by combining a common source and a common drain amplifier to have a high slew rate and to minimize the quiescent current. The proposed circuits are simulated in a high-voltage 0.6${\mu}{\textrm}{m}$ CMOS process, dissipates only 20${\mu}{\textrm}{m}$ static current, and have 83dB open-loop DC gain and 60$^{\circ}$phase margin.

  • PDF

A study on the 200W class QR flyback DC-DC converter with synchronous rectifier (동기정류기를 이용한 200W급 공진형 플라이백 DC-DC 컨버터에 관한 연구)

  • Won, Ki-Sik;Ahn, Tae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.295-297
    • /
    • 2005
  • This paper presents a novel current driving method for the synchronous rectifier (SR) in a Flyback topology. The proposed current driven synchronous rectifier features low Power loss, good performance and the gate voltage of FET in the synchronous rectifier is easily controlled by zener voltage. The proposed SR driving method is implemented in a 200W Flyback converter with 400Vdc input and achieved excellent performance at full load.

  • PDF

On-Line Optimal Efficiency Control for Permanent Magnet Synchronous Motors Driving electric Vehicles (전기자동차 구동용 영구자석형 동기전동기의 온라인 최적 효율제어)

  • Chun, Tae-Won
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.4
    • /
    • pp.586-593
    • /
    • 1994
  • This paper suggests the algorithm for on-line efficiency control of permancent magnet synchronous motors driving the electric vehicles. The existance of unigue d-axis current is verified, which generates the maximum efficiency at operating points of motor. Using the Fibonacci search method, d-axis current converges to the minimization of inverter input power, and to prevent the variation of motor speed in process of the efficiency control, the voltage decoupled control strategy is introduced. Through the experiments, the effects of an efficiency control algorithm are verified.

A study on QR flyback DC-DC converter for synchronous rectifier (공진형 플라이백 DC-DC 컨버터용 동기정류기에 관한 연구)

  • Won, Ki-Sik;Ahn, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1395-1397
    • /
    • 2005
  • This paper presents a novel current driving method for the synchronous rectifier(SR) in a flyback topology. The proposed current driven synchronous rectifier features low power loss, good performance and the gate voltage of FET in the synchronous rectifier is easily controlled by resistor ratio. The proposed SR driving method is implemented in a 200W Flyback converter with 400Vdc input and achieved excellent performance at full load.

  • PDF