• Title/Summary/Keyword: current division

Search Result 4,474, Processing Time 0.029 seconds

Novel Zero-Voltage and Zero-Current-Switching (ZVZCS) Full Bridge PWM Converter with a Low Output Current Ripple (낮은 인덕터 맥동전류를 가지는 새로운 영전압 영전류 스위칭 풀 브릿지 DC/DC 컨버터)

  • Baek, J.W.;Cho, J.G.;Yoo, D.W.;Song, D.I.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2204-2206
    • /
    • 1997
  • A novel zero voltage and zero current switching (ZVZCS) full bridge (FB) PWM converter with a low output current ripple is proposed. The proposed circuit improve the demerits of the previously presented ZVBCS-FB-PWM converters[5-8] such as use of lossy components or additional active switches. A simple auxiliary circuit which includes neither lossy components nor active switches provides ZVZCS conditions to primary switches, ZVS for leading-leg switches and ZCS for lagging-leg switches. In addition, this proposed circuit reduces a output current ripple considerably. Many advantages including simple circuit topology, high efficiency, low cost and low current ripple make the new converter attractive far high power (> 1kW) applications.

  • PDF

DSP-Based Direct Source Current Control for Three-Phase Four-Wire Power Coditioner

  • Jeong, C.Y.;Cho, J.G.;Baek, J.W.;Yoo, D.W.;Song, E.H.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.871-875
    • /
    • 1998
  • A DSP-based source current control for power conditioner is presented to compensate current harmonics and asymmetries of three-phase four-wire emergency generators caused by nonlinear and/or unbalanced loads. There-phase voltage type converter with split-dc-capacitor is adopted as the power circuit and a new direct source current control method is suggested, which simplifies the controller. The proposed control method shapes the generator current sinusoidally inphase with the voltage and allows the generator to supply maximum power even to single phase loads. An IGBT base lookVA prototype with the controller realized with a DSP (TMS320C32) is built and tested to verify the performance of the power conditioner.

  • PDF

Thermally Stimulated Depolarization Current Test for Reliability of X5R MLCC (TSDC 방법을 이용한 X5R MLCC의 신뢰성 평가)

  • Park, Ji-Young;Park, Jae-Sung;Kim, Young-Tae;Hur, Kang-Heon
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.2
    • /
    • pp.155-160
    • /
    • 2009
  • The reliability could be one of the essential properties for multilayer ceramic capacitor (MLCC) using in various electronic devices and the concentration and mobility of oxygen vacancy would play important role in the reliability. To investigate the migration behavior of oxygen vacancies, thermally stimulated depolarization current (TSDC) is adopted. In dielectric material of X5R MLCC, the TSD-Current peak observed around 150$^{\circ}C$ and 200$^{\circ}C$ which represented the migration of oxygen vacancy. Substituting Yttrium for Dysprosium in X5R MLCC showed higher migration activation energy and lower TSD current density.

Physical Oceanographic Characteristics in Hupo Coastal area during Summer and Autumn, 2007 (2007년 하계 및 추계 경상북도 후포연악역 물리적 해황특성)

  • Hwang, Jae-Dong;Lee, Yong-Hwa;Shim, Jeong-Min;Young, Seok-Hyun;Jin, Hyun-Gook;Kim, Young-Suk;Kwon, Kee-Young;Yoon, Sang-Chol
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.505-510
    • /
    • 2008
  • To understand the oceanographic characteristics of Hupo coastal waters as regards the East Korean Warm Current and the North Korean Cold Current, current direction and velocity were investigated by deploying a current meter in Hupo coastal waters during the summer and fall of 2007. Wind data were obtained from the homepage of the Korea Meteorological Administration. Water temperature was measured using a temperature meter attached to the current meter and a mini log. During summer, a south wind prevailed, while during the fall the wind blew from the north. Cold surface waters occurred on a large scale in summer, while in the fall, warm bottom water occurred frequently. After mid-November, when the surface water was cooler than $15^{\circ}C$, there was no difference in water temperature between the surface and bottom layers.

Effect of Additional Electrical Current on Adhesion Strength between Copper and Polyimide Films (인가 전류가 구리 도금 피막과 폴리이미드 필름의 접합력에 미치는 영향)

  • Lee, Jang-Hun;Han, Yoonsung;Lee, Ho-Nyun;Hur, Jin-Young;Lee, Hong Kee
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • The effect of the additionally applied electrical current on the adhesion strength between electroless Cu and polyimide films was investigated. Peel tests were performed after applying electrical current within the range from 0.1 to 100 mA for the duration from 1 to 30 minutes. Sample with more than 1 mA of additional electrical current for 1 minute showed higher adhesion strength than that without additional electrical current. However, samples with 10 mA of additional electrical current for more than 10 miniutes showed the degradation of adhesion strength. Ra and RMS values of the peeled polyimide surface were proportional to the adhesion strength though there were no significant changes in the morphology of the peeled surfaces with varied amount and time-length of additional electrical current. Applying electrical current could increase the density of chemical bonding, which results in increase of the adhesion strength between copper and polyimide. However, in the case of applying additional electrical current for excessive amount or time, the degradation of the adhesion strength owing to the formation of copper oxide at the interface could occur.

DC Motor Drive System Using Embedded Target for TI C2000DSP in Matlab/Simulink (Matlab/Simulink의 TI C2000 DSP 임베디드 타겟을 이용한 직류 전동기 구동 시스템)

  • Jeon, Han-Young;Lee, Yong-Seok;Ji, Jun-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1027-1028
    • /
    • 2006
  • In this paper, design of current and speed controller for DC motor drive system using Embedded Target for TI C2000DSP in Matlab/Simulink is introduced. Current and speed controller is designed and implemented using program simply and easily, and speed control response of DC motor can be advanced. Current and speed control of DC motor is carried in eZdsp F2812 control board using Embeded Target for TI C2000DSP in Matlab/Simulink. Speed feedback is processed through A/D converter using tacho generator as speed sensor, and current feedback is processed through A/D converter using hall sensor as current sensor. Controller is designed to PI current controller and PI speed controller. Current and speed response is verified through simulations and experiments.

  • PDF

Numerical Study of Current and Wind Forces Acting on Two Floating Bodies in Tandem Configuration (직렬 배치된 두 부유체에 작용하는 조류력 및 풍력 특성에 관한 수치해석 연구)

  • Hong, Jang-Pyo;Nam, Bo Woo;Yoon, Kyoung-Won;Kim, Young-Sik;Sung, Hong-Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.378-386
    • /
    • 2014
  • In this study, the characteristics of the current and wind forces acting on two floating bodies were numerically investigated using a commercial CFD software, STAR-CCM+. In the numerical analyses, LNGC was located right behind FSRU under uniform current or wind conditions. Steady calculations were carried out using a Reynolds averaged Navier-Stokes (RANS) solver and the realized k-epsilon model. First, the current coefficients of FSRU based only the CFD were compared with the model test data. Through this comparison, the present numerical models and mesh systems were indirectly verified. Next, computations for FSRU and LNGC in a uniform current were performed using different relative positions. It was found that the current coefficients were great affected by the longitudinal positions. Finally, the wind forces acting on FSRU and LNGC in tandem configurations were studied. The focus was on the shielding effects due to the aerodynamic interactions between FSRU and LNGC.

The Tsushima Warm Current from a High Resolution Ocean Prediction Model, HYCOM (고해상도 해양예보모형 HYCOM에 재현된 쓰시마난류)

  • Seo, Seongbong;Park, Young-Gyu;Park, Jae-Hun;Lee, Ho Jin;Hirose, N.
    • Ocean and Polar Research
    • /
    • v.35 no.2
    • /
    • pp.135-146
    • /
    • 2013
  • This study investigates the characteristic of the Tsushima Warm Current from an assimilated high resolution global ocean prediction model, $1/12^{\circ}$ Global HYbrid Coordiate Ocean Model (HYCOM). The model results were verified through a comparison with current measurements obtained by acoustic Doppler current profiler (ADCP) mounted on the passenger ferryboat between Busan, Korea, and Hakata, Japan. The annual mean transport of the Tsushima Warm Current was 2.56 Sverdrup (Sv) (1 Sv = $10^6m^3s^{-1}$), which is similar to those from previous studies (Takikawa et al. 1999; Teague et al. 2002). The volume transport time series of the Tsushima Warm Current from HYCOM correlates to a high degree with that from the ADCP observation (the correlation coefficient between the two is 0.82). The spatiotemporal structures of the currents as well as temperature and salinity from HYCOM are comparable to the observed ones.

Effect of Ammonium and Nitrate on Current Generation Using Dual-Cathode Microbial Fuel Cells

  • Jang, Jae-Kyung;Choi, Jung-Eun;Ryou, Young-Sun;Lee, Sung-Hyoun;Lee, Eun-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.2
    • /
    • pp.270-273
    • /
    • 2012
  • These studies were conducted to determine the effects of various concentrations of ammonium and nitrate on current generation using dual-cathode microbial fuel cells (MFCs). Current generation was not affected by ammonium up to $51.8{\pm}0.0$ mg/l, whereas $103.5{\pm}0.0$ mg/l ammonium chloride reduced the current slightly. On the other hand, when $60.0{\pm}0.0$ and $123.3{\pm}0.1$ mg/l nitrate were supplied, the current was decreased from $10.23{\pm}0.07$ mA to $3.20{\pm}0.24$ and $0.20{\pm}0.01$ mA, respectively. Nitrate did not seem to serve as a fuel for current generation in these studies. At this time, COD and nitrate removal were increased except at $123{\pm}0.1$ mg ${NO_3}^-/l$. These results show that proper management of ammonium and nitrate is very important for increasing the current in a microbial fuel cell.

Critical currents across grain boundaries in YBCO : The role of grain boundary structure

  • Miller Dean J.;Gray Kenneth E.;Field Michael B.;Kim, Dong-Ho
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.14-19
    • /
    • 1999
  • Measurements across single grain boundaries in YBCO thin films and bulk bicrystals have been used to demonstrate the influence of grain boundary structure on the critical current carried across the grain boundary. In particular, we show that one role of grain boundary structure is to change the degree of pinning along the boundary, thereby influencing the critical current. This effect can be used to explain the large difference in critical current density across grain boundaries in thin films compared to that for bulk bicrystal. These differences illustrate the distinction between the intrinsic mechanism of coupling across the grain boundary that determines the maximum possible critical current across a boundary and the measured critical current which is limited by dissipation due to the motion of vortices.

  • PDF