• Title/Summary/Keyword: current consumption

Search Result 2,050, Processing Time 0.03 seconds

An On-Chip Differential Inductor and Its Use to RF VCO for 2 GHz Applications

  • Cho, Je-Kwang;Nah, Kyung-Suc;Park, Byeong-Ha
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.83-87
    • /
    • 2004
  • Phase noise performance and current consumption of Radio Frequency (RF) Voltage-Controlled Oscillator (VCO) are largely dependent on the Quality (Q) factor of inductor-capacitor (LC) tank. Because the Q-factor of LC tank is determined by on-chip spiral inductor, we designed, analyzed, and modeled on-chip differential inductor to enhance differential Q-factor, reduce current consumption and save silicon area. The simulated inductance is 3.3 nH and Q-factor is 15 at 2 GHz. Self-resonance frequency is as high as 13 GHz. To verify its use to RF applications, we designed 2 GHz differential LC VCO. The measurement result of phase noise is -112 dBc/Hz at an offset frequency of 100 kHz from a 2GHz carrier frequency. Tuning range is about 500 MHz (25%), and current consumption varies from 5mA to 8.4 mA using bias control technique. Implemented in $0.35-{\mu}m$ SiGe BiCMOS technology, the VCO occupies $400\;um{\times}800\;um$ of silicon area.

Thermal Insulation Methods of Buildings for Energy Conservation (에너지 절약을 위한 건축물의 단열 방안)

  • Koo, Jae-Oh
    • Journal of Industrial Technology
    • /
    • v.4
    • /
    • pp.15-23
    • /
    • 1984
  • In recent years, the energy consumption in building sector has been increased greatly because of the rapid pace of urbanization and of the growing economy. In this paper, the current status and problems of energy consumption in buildings are presented. And several modification options which reduce the energy consumption are suggested. Finally five considerations for energy saving policy are presented in brief.

  • PDF

Application of Frost Detecting Sensors in Refrigerators to Reduce Energy Consumption (냉장고 소비전력 저감을 위한 착상감지센서의 응용 연구)

  • 성창용;나승유;이희영
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.147-150
    • /
    • 2000
  • Manual and predictive defrosting method is used in current refrigerators, which have several problems in terms of energy consumption and efficiency. fuming the defrosting system on by the amount of frost remains to be an important problem which has to be improved by refrigerator manufacturers. The sensing of the amount of frost by FDS(Frost Detecting Sensor) and its proper mounting point are investigated in the paper. Also the realization of actual defrosting system through experiments of operation, energy consumption and sensing mechanism is presented.

  • PDF

Green Mode Buck Switch for Low Power Consumption

  • Jang, KyungOun;Kim, Euisoo;Lim, Wonseok;Lee, MinWoo
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.397-398
    • /
    • 2013
  • Fairchild Green Mode off line buck switch for low standby power consumption and high reliability is presented. By reducing operating current and optimizing switching frequency, 20mW power consumption is achieved. High performance trans-conductance amplifier and green mode function improve the ripple and regulation in the output voltage. The conventional $FPS^{TM}$ buck and novel Fairchild buck switch are compared to show the improvement of performance. Experimental results are showed using 2W evaluation board.

  • PDF

Design of A Voltage-controlled Frequency Tunable Integrator and 3rd-order Chebyshev CMOS Current-mode Filter (전압제어 주파수가변 적분기 및 3차 체비세프 CMOS 전류모드 필터 설계)

  • Bang, Jun-Ho;Lee, Woo-Choun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3905-3910
    • /
    • 2010
  • In this paper, a 3rd-order Chebyshev current-mode filter in 1.8V-$0.18{\mu}m$ CMOS parameter is designed. The core circuit of the current-mode filter is composed with the proposed voltage-controlled frequency tunable current-mode integrator. Using the proposed current-mode integrator, the cutoff frequency of the filter can be controlled and also total power consumption can be reduced. HSPICE simulation results show the cutoff frequency of the filter is controlled between 1.2MHz and 10.1MHz, and the power consumption is 2.85mW at Vdd=1.8V.

A Study on the Operating Characteristics of Commercial Frequency Plasma Jet Torch (상용 주파수 (60Hz) Plasma Jet Torch의 동작특성에 관한 연구)

  • 전춘생;정재웅
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.75-85
    • /
    • 1975
  • In order to develop the commercial frequency (60Hz) plasma torch of small capacity for material cutting, welding and other industrial heating, the A.C plasma jet generator of non-transfered type is made domestically and the electrode configurations of plasma torch are composed of two kinds of electrodes W-C and W-Cu, combined by thermal emission and field emission electrode materials. In this paper, the characteristics of input power, thermal efficiency, electrode consumption, the flame and forms of arc voltage and arc current for A.C plasma torch are investigated in relation to such variables as arc current, argon flow and magnetic field intensity to obtain the basic design data necessary to A.C plasma jet generator. The result are as follows; (1)The input power, thermal efficiency and electrode consumption are influenced greatly by argon flow, magnetic field intensity and nozzle materials. (2)A.C arc voltage and current are non-symmetrial, involving D.C Component. Due to this current of D.C Component, transformer core is saturated and a large abnormal current flows into the primary winding coil. In order to prevent this abnormal current flow, a condenser must be connected in series to the main discharge circuit. (3)The stability and sharpness of jet flame are improved more in the torch of W-C electrode configuration than in the torch of W-Cu electrode configuration.

  • PDF

Differences in Food and Nutrient Intake Associated with Smoking Status of Korean

  • Kim, Youngok
    • Journal of Community Nutrition
    • /
    • v.4 no.1
    • /
    • pp.22-28
    • /
    • 2002
  • The purpose of this study was to investigate the differences in food and nutrient intake by smoking status among Korean. Food and nutrient intake in relation to smoking status was studied in 7,370 adults, aged 20 years and older in 1998 Korean National Health and Nutrition Survey, in which 24 hour recall method was used for dietary survey. Information of subject's smoking status was collected by interview as a part of health behavior survey. Analysis of variance was used to test the differences in food and nutrition intake among subjects following after Duncan's multiple range test among four different smoking exposure categories. Food intake of male ex-smoker was the highest in most of the food groups among the four groups of daily current smoker, occasional current smoker, ex-smoker and never smoker. There was significant differences observed in food intake of sugar, fruits, beverage, seasoning by the smoking status. It had been also observed that significantly high intake of energy from carbohydrate in non smoker compare to current smoker especially in male subjects. Fiber and vitamin C intake was also higher among non-smoker (never smoker and ex-smoker) than current smoker. In general, food and nutrient intake pattern of ex-smoker resembled those of never smoker than those of current smoker. Not likely the observation from European and American studies, fat intake was not statistically different between smoker (current) and non-smoker (ex-smoker and never smoker) among Korean.

A Study on the Cathodic Protection Design Optimization of Steel Piles for LNG Storage Tanks by Numerical Analysis (수치해석에 의한 LNG 저장탱크용 강관파일 전기방식 설계 최적화 연구)

  • Kim, Young Keun;Song, Hong Seok
    • Corrosion Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.294-297
    • /
    • 2017
  • For the longer service life of steel pile, cathodic protection is selected sometimes at corrosive environment. The cathodic protection design improvement was investigated in this study. The current demand for cathodic protection was calculated from the potentiostatic current monitoring of the steel specimen in the deaerated soil samples. In this study, the current distribution was studied using the Boundary Element Method (BEM) and the Finite Element Method (FEM) numerical analysis methods. The optimum layout of the anode was developed and confirmed by numerical analysis. Under the conventional design of the anode, the length of the anode hole is same as the pile length. We found that, at the bottom end of the pile, the current density is too high. When the anode hole length was 80% of the pile length, the current consumption at the end was reduced. The construction cost of anode hole drilling was decreased about 20%, as compared to the conventional design. Furthermore, the life of the anode materials could be extended by reducing the current consumption at the end section. Using this approach, the construction cost was reduced significantly without any under-protection area on the steel piles.

Evaluation of the Applicability of Livestock Wastewater Treatment using Boron-Doped Diamond (BDD) Electrodes (BDD 전극을 이용한 축산폐수 처리의 적용성 평가)

  • Hyun-Gu Kim;Dae-Hee Ahn
    • Journal of Environmental Science International
    • /
    • v.32 no.6
    • /
    • pp.465-475
    • /
    • 2023
  • In this study, we evaluated the treatment efficiency of livestock wastewater by altering the current density using boron-doped diamond (BDD) electrodes. As the current density was adjusted from 10 to 35 mA/cm2, the removal efficiency of organic matter increased from 22.2 to 71.5%. Similar to that of organic matter, the removal efficiency of color increased with increasing current density up to 85.7%, indicating a higher removal efficiency for color than that of organic matter. The removal efficiency of ammonia nitrogen increased from 14.6 to 53.3% as the current density increased, but it was lower than that of organic matter. In addition, the removal of organic matter, color, and ammonia nitrogen followed first-order reactions, according to the reaction rate analysis. The energy consumption ranged from 4.87 to 8.33 kWh/kg COD, and it was found that the organic matter removal efficiency was more efficient at high current densities. Based on various analyses, the optimal current density was 20 mA/cm2, and the corresponding energy consumption was 6.824 kWh/kg COD.

Study on Energy Consumption according to Building Envelope Performance and Indoor Temperature (건축물의 외피성능 및 실내온도에 따른 에너지 사용량에 관한 연구)

  • Yoo, Ho-Chun;Kang, Hyun-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.101-108
    • /
    • 2011
  • This study aims to suggest an energy consumption improvement plan for university buildings through an analysis of energy consumption. Upon a simulation of subject building to interpret energy consumption, it was found that 154.07kWh/$m^2$ of energy is consumpted annually. Improvement of design elements can cut down the energy consumption to 135.61kWh/$m^2$ according to an energy reduction analysis related to envelope performance improvement. Additional improvement of lights and heat exchanger can curtail annual energy consumption to 108.32kWh/$m^2$. Also, an analysis of energy consumption while increasing indoor temperature gradually showed that the two factors are in proportion. $6^{\circ}C$ higher temperature requires over twice of the current energy. Based on this survey result, performance improvement due to building management and envelope elements which influence to building cooling and heating loads can curtail building energy consumption.