• Title/Summary/Keyword: current capacity

Search Result 2,588, Processing Time 0.038 seconds

A Novel Hybrid Sequential Start Control System for Large Inductive Loads

  • Kim, Sang-Kon;Kim, Tae-Kon
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.388-394
    • /
    • 2015
  • The inrush current of a large inductive load can be reduced with a soft starter; however, the large inrush current caused by simultaneous bulk starts (SBSs) cannot be effectively reduced. In order to reduce the high inrush current and voltage sag owing to the SBSs of large capacity inductive loads within a power network, a novel hybrid sequential start control system is proposed, implemented on embedded systems, and evaluated with a testbed in this study. From the experimental and simulation results of the proposed control system, the inrush current could be effectively restricted below the maximum current capacity of a power distributing board. Moreover, with the proposed system, power cost typically dictated by the peak power consumption can be fairly reduced, and the quality of the power system connected to the inductive loads can be efficiently increased.

Digital Current Controller with Smith-Predictor for PWM Converters

  • Lee, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.7-11
    • /
    • 1996
  • From the cost-effective point of view, it is very important to design a current with the highest utilization factor of current capacity of power devices. This can be accomplished by a current controller without overshoot irrespective of the varying bounds of control voltage in PWM converters and the dead time due to the time delay. This paper suggests a novel decoupled controller with Smith-Predictor which has the fast control response without overshoot and steady stats error and also deal with the design method of the controller for PWM converters. The extensive digital simulations done by SIMULINK/MATLAB show that the suggested controller guarantees the full utilization of current capacity of power devices and the decoupled current control behavior.

  • PDF

Current Properties Of Photoisomerization Organic Monolayer (광학이성 유기단분자막 전류특성)

  • 김동관;강용철;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.487-490
    • /
    • 1999
  • The Maxwell displacement current was generated from 4-octyl-4'-(5-carboxyl-pentamethyleneoxy)- azobenzene (denoted as 8A5H) monolayer Langmuir-Blodgett films prepared on Cr/Au-coated glass substrates due to trans-cis photoisomerization of 8A5H by application of alternate irradiation with UV light and Visible light. The displacement current was generated due to the trans-to-CIS photoisomerization by irradiation with ultraviolet light($\lambda_1$=360nm). Whereas the displacement current was generated in the opposite direction due to the cis-to-trans photoisomerization by photoirradiation with visible light($\lambda_2$=450nm). Finally, We concluded that Displacement current change according to power capacity photoirradiation, the more higher generate the more higher power capacity magnitude.

  • PDF

A Study on Electrical Degradation Properties of Epoxy Resin due to Moisture Absorption (흡습에 의한 에폭시 수지의 전기적 열화 특성에 관한 연구)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.656-661
    • /
    • 2013
  • In this study, the moisture content, charge discharge current, electrostatic capacity and dielectric loss tangent are measured for the specimen of bisphenol type epoxy resin which is mixed with squared amorphous silica filler and dipped in hot water of $50^{\circ}C$ for 169 days. The results of this study are listed below. The longer of deposition day, the charge and discharge current was increased. It is considered that the reason is because there was water attack through the squared silica surface. The longer of deposition day, the absorption rate of all specimens was increased. It found that the absorption rate reached saturated state after 100 days. The higher frequency and the longer of deposition day, the $tan{\delta}$ was decreased. Also, It found that the $tan{\delta}$ and electrostatic capacity of the specimen which is mixed with squared filler are greater.

An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation (154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

A study or Metallic sheath for Extra-high voltage XLPE cable (초고압 XLPE 케이블 금속 차폐층 고찰)

  • Choi, C.S.;Lee, K.J.;Chung, M.Y.;Kwon, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

Selection of Capacity of Circuit Breaker by Probabilistic Short-Circuit Current Analysis (확률적 고장전류 해석에 의한 차단기 용량 선정)

  • 문영현;오용택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.1
    • /
    • pp.10-15
    • /
    • 1990
  • This paper presents an algorithm that can compute equivalent impedance effctively in computing 3-phase short circuit current which would be generated in power systems. Also this paper proposes a method that can decide the capacity of circuit breaker by analysing the fault current distribution probabilistically when the fault point of specificed line varies. The efficiency of the algorithm was verified by applying the proposed method to IEEE-6bus system and IEEE-30bus system, and probabilistic fault analysing method is verified economic in facility investment by deciding the proper capacity of circuit breaker.

  • PDF

Reduce Power of Magnetic Contactor using the Two-Level Apply Voltage (Two-Level 전압 인가에 의한 전자접촉기 구동 전력 저감)

  • Kang-Yeol Lee;Hye-Young Na;Seong-Mi Park;Sung-Jun Park;Gyoung-Jong Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.925-936
    • /
    • 2023
  • Currently, due to the rapid increase in power demand and the increase in capacity of power converters, the capacity of electromagnetic contactors is also increasing, and the burden on SMPS for the power that can drive them is increasing. Although the initial starting operation current of an electromagnetic contactor is significantly larger than the holding current for maintaining contact, most electromagnetic contactors apply the same voltage as the initial starting operation. An electromagnetic contactor must continuously apply a holding current to maintain the contact point, and the larger the capacity, the larger the current must be applied. This paper proposes a two-level magnetic contactor drive that allows setting the initial starting operation current to fully attach the contact point of the magnetic contactor and the holding current to maintain subsequent operation. In addition, a low-cost drive topology of analog and digital methods was proposed for various field applications, and an algorithm based on the ripple of the excitation current was proposed to determine whether the magnetic contactor was opened or closed without using a separate contact point. The feasibility of the proposed method was proven through Psim simulation experiments.

Considerations and Suggestions for Expressing of Seismic Capacity of Buildings (건축물 내진능력 표현에 관한 고찰 및 제언)

  • Lee, Cheol Ho;Park, Ji-Hun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.7_spc
    • /
    • pp.517-526
    • /
    • 2016
  • In this paper, some popular intensity measures of earthquakes including magnitude, MMI, and PGA as well as their empirical relationships are briefly reviewed since they have been widely used without prudence by mass media, the public, and even the government when asking or expressing the seismic capacity of buildings. The basic concept of current seismic design is also presented in order to facilitate relevant discussions. It is emphasized that expressing the building seismic capacity simplistically in terms of seismological quantities or terminologies like magnitude and MMI is inherently irrational, may be misleading the stakeholders, and should be avoided. Alternative expressions, more rational and consistent with current seismic design philosophy and practice, are recommended.

A Plan to Develop Seismic Capacity Verification Procedures Based on the Elastic-Plastic Strain Features (탄소성 변형률 기반 내진성능 평가 절차서 개발 방안)

  • Hwang, Jong Keun;Jeong, Ill Seok;Kim, Beom Shig;Ahn, Sang Won;Bang, Hye Jin;Lee, Min Hee;Jeong, Hyeon Seob
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.2
    • /
    • pp.11-15
    • /
    • 2018
  • A development plan for seismic capacity verification procedures of nuclear components based on the elastic-plastic strain (EPS) features is explained in this paper. The EPS methodology is more realistic to assess seismic responses of components to extreme seismic events beyond the safe shutdown earthquake (SSE) than current practices with the criteria of stress limits. The EPS based approach to analyze the seismic capacity of components can reduce over-conservatism in the current stress-based criteria and can incorporate the seismic responses of components deformed in plastic behavior by the motion of extreme earthquake.