• 제목/요약/키워드: current capacity

검색결과 2,588건 처리시간 0.03초

IEC 60909에 의한 삼상 고장계산 (Three-phase Fault Calculation by IEC 60909)

  • 손석금
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.12-18
    • /
    • 2014
  • This paper analyzes how to calculate the three phase short circuit current calculation procedures used in the IEC 60909 short circuit. It presented the new procedure of the fault current for the interrupting capacity of the circuit breaker. This procedure is applied to the future power system and calculates the fault current. Power demands are increased because of the growth of the economy for this reason, the fault current of the power system is largely increased and the fault current procedure for the proper interrupting capacity calculation of the existing or the new circuit breaker is essential. How to calculate the three phase short circuit current for ac electrical system and select the high voltage and low voltage circuit breaker based on IEC 60909 standards.

초전도기기를 적용한 미래 저압대용량 신 배전계통 (Future New Distribution System with Low voltage and Mass Capacity using HTS equipments)

  • 윤재영;김종율;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.37-41
    • /
    • 2005
  • This paper describes the construction scheme of new distribution system using HTS(High Temperature Superconducting) power equipments such as cable, transformer and FCL(fault current limiter). At present, one of the most serious problems in distribution power system, especially for metropolitan complex city, is to obtain the ROW for cable line routes, space for downtown substations and satisfy the environmental protection caused by NIMBY phenomena. Unfortunately, it is expected that this situation will get more and more worse. As the HTS technology to apply in power system Is developed, HTS cable utilizing mass-capacity characteristic can be a useful countermeasure to overcome this problem. This paper describes the application methodology of 22.9kV HTS cable with low-voltage, mass-capacity characteristics replacing the 154kV conventional cable. By applying 22.9kV HTS cable, the HTS transformer with higher capacity for the reduction of space and transformer numbers of downtown substation is necessary. Also, if the leakage Impedance of HTS transformer is same as or lower than that of conventional transformer, the fault current of 22.9kV bus will increase because the HTS transformer capacity is larger than that of the conventional transformer. This means the parallel application of HTS-FCL to reduce the fault current in addition to the HTS cable and transformer can be necessary. With the basic construction scheme of new distribution system, this paper describes the future study points to realize this new distribution system using HTS equipments.

tDCS를 결합한 고강도 인터벌 훈련이 축구선수의 유산소 운동능력에 미치는 영향 (The Effects of Transcranial Direct Current Stimulation Combined High Intensity Interval Training on Aerobic Exercise Capacity of the Soccer Player)

  • 양대중;엄요한
    • 대한통합의학회지
    • /
    • 제9권4호
    • /
    • pp.105-117
    • /
    • 2021
  • Purpose : This study examined the effect of transcranial direct current stimulation (tDCS) combined high intensity interval training (HIIT) on the aerobic exercise capacity of college soccer players. Methods : The subjects of this study were 30 college soccer players. They were divided into a high intensity interval training group combining transcranial direct current stimulation (Group I) and a high intensity interval training group (Group II). Each group had 15 subjects randomly assigned. After receiving general soccer training, each group additionally received high intensity interval training combined with transcranial direct current stimulation and high intensity interval training for 30 minutes 5 times a week for 8 weeks. Their VO2max and 20 meter shuttle run test, Yo-Yo intermittent recovery test were analyzed before the intervention. After 8 weeks of intervention, the above items were re-measured and an intergroup analysis was performed. Results : As a result of comparative analysis of VO2max intake between groups, 20 meter shuttle run test and Yo-Yo intermittent recovery test, a statistically significant difference was found. The high intensity interval training group (Group I) combined with transcranial direct current stimulation showed a significant difference in aerobic exercise capacity compared to the high intensity interval training group (Group II). Conclusion : These results showed that high intensity interval training group combined with transcranial direct current stimulation was more effective for aerobic exercise. Based on this study, this study proposes an effective program for patients as well as elite athletes. In the future, it is necessary to develop an effective transcranial direct current stimulation program and to study how to apply it for various patients.

A Study on the Mixing method and Mixing Temperature of Positive Paste to Improve the Capacity of the Lead-Acid Batteries

  • Jeong, Soon-Wook
    • 한국응용과학기술학회지
    • /
    • 제33권3호
    • /
    • pp.568-574
    • /
    • 2016
  • In this study, the mixing method of positive paste and mixing temperature to improve the capacity of the lead-acid batteries has been investigated. The results show that the initial current capacity of lead acid battery depend on the mixing temperature and mixing method of positive paste. In the results of the capacity cycle repetition tests for estimating the life cycle, the 3BS showed the PCL. but the fine 4BS represented certain improved cycles compared to that of the coarse 4BS. It was considered that the fine 4BS showed higher bond strength between active materials than the coarse 4BS and represented large contact areas and that lead to prevent possible sulfation due to the suppression of insulating layers.

기계적 접점을 이용한 FCL의 동작 특성 (Operational Characteristics of the FCL Using the Mechanical Contact in the Power System)

  • 정병익;최효상
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.878-882
    • /
    • 2016
  • These days, SFCLs are being developed in order to limit fault current. However, the superconducting elements that limit the fault current have such problems as capacity increase and require auxiliary devices including cooling device. If devices that comprise the current power network can withstand fault current for at least one cycle, it is possible to limit the fault current with current limiting elements by bypassing it on the fault line. In this study, the fault current limiter was configured with current transformer, vacuum interrupter, and current limiting element. Through the experience, it was confirmed that the fault current was limited within one cycle. The superconducting element, as a current limiting element, limited the fault current by 80 % within one cycle from fault occurrence, and the passive element limited it more than 95 %. Also, through the comparison between resistance curve and power consumption curve, it was confirmed that the current limiting element using a passive element was more stable than the superconducting element that required capacity increase and other auxiliary devices. It was considered that the FCL proposed in this study could limit fault current stably within one cycle from fault occurrence by using the existing power technologies such as fault current detection and solenoid valve operating circuit.

PWM Converter의 새로운 전류제어기 (A New Current Controller for PWM Converters)

  • 이진우;민종진;백상기;강병희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.410-412
    • /
    • 1995
  • From the cost-effective product point of view, it is very important to design a new current controller with the highest utilization factor of current capacity of power devices. This paper deals with a state-deadbeat current controller for PWM converters, which shows the fastest current control response without overshoot irrespective of the saturation of control voltage. No-overshoot control response means that the current capacity could be fully utilized in the control sense. Simulational results done by Matlab's Simulink show good current control characteristics.

  • PDF

비영리 사회복지조직의 재정자원동원 효과성과 조직의 관리능력 (Does Organizational Capacity Explain Fundraising Effectiveness in Nonprofit Social Service Organizations?)

  • 노연희
    • 한국사회복지학
    • /
    • 제58권3호
    • /
    • pp.5-26
    • /
    • 2006
  • 본 연구는 어떠한 요인들이 비영리 사회복지조직의 자원동원활동의 효과성을 설명하는지를 살펴보기 위해 수도권 지역의 사회복지조직에서 자원동원활동을 수행한 적이 있는 종사자를 대상으로 설문조사를 실시하였다. 본 연구는 조직의 일반 특성과 자원동원관련 특성뿐만 아니라, 조직의 관리능력이라는 새로운 요인을 투입하여 계층적 회귀분석을 실시하였다. 비영리 사회복지조직에 있어서 자원동원활동의 효과성은 기존의 연구에서 제시하는 조직의 일반 및 자원동원관련 특성과 같은 객관적 조건보다 조직이 구체적인 기법을 활용하는지 그리고 조직이 이 활동을 어느 정도 지원하는지를 보여주는 조직의 관리능력이라는 주관적 조건이 영향을 미친다는 분석결과는 실천적 측면에서 효과적인 자원동원을 위해서는 조직의 적절한 지원과 관리의 중요성을 제시하는데 의의를 지닌다.

  • PDF

접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가 (Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation)

  • 문기훈;한상환;하성진
    • 한국지진공학회논문집
    • /
    • 제18권2호
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

주거용 건축물의 재실자밀도 기준 적정성 평가에 관한 연구 (A Study on the Adequacy Evaluation of Criteria of Occupant Load Factor in Residential Buildings)

  • 서동구;황은경
    • 한국주거학회논문집
    • /
    • 제27권6호
    • /
    • pp.145-153
    • /
    • 2016
  • The purpose of this study is to grasp the effectiveness of evacuation safety design by verifying the appropriateness of the standard of occupant load factor for residential buildings. To this end, the definition and current standard of occupant load factor for residential buildings were analyzed, and the problems of the current standard were clarified by interviewing professionals. In addition, changes in occupant load factor were examined by year based on statistical research, and evaluation on the current standard $18.6m^2/pers.$ was performed. As for evaluation methods, the need of redesigning of evacuation capacity was investigated by using evacuation simulation. As a result of the analysis, the most serious problem was clarification of the applicable standard for residential officetel, where the average occupant load factor was $26.1m^2/pers.$, which was not appropriate. However, as a result of evaluation on evacuation capacity, although there was no difference between statistical research results and the current standard in terms of evacuation capacity, when the standard for business facilities was applied to officetel, evacuation time doubled. Thus, this study suggests that when the current standard is applied to residential officetel, it is necessary to separate between residential use and business use.

납축전지 극판의 숙성 조건이 양극판의 화학적 조성에 미치는 영향 (Effects of Curing Conditions on the Chemical Compositions of Positive Plate for Lead Acid Battery Plates)

  • 구본근;정순욱
    • 한국응용과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.347-354
    • /
    • 2006
  • Generally, it has been known that positive plate efficiency is the most influential effect on the initial current capacity of lead acid battery. Thus, in this study, we have investigated the curing effect of the positive plate, which is one of the important lead acid battery processes. The curing process of the positive plate is performed either with the separation of each plate with 1mm gap or with no gap of plate. As a result, when there is no interval between each plate, the higher temperature current happened than expected, resulting in the changes in the initial current efficiency of the lead acid battery. The chemical composition and crystal structure of a material coated on the positive plate were identified with XRD and SEM. It was resulted that were only there not a lot of 4BS (tetrabasic-lead sulfate, $4PbO{\cdot}PbSO_4)$ on the plate in case of curing of plates without interval, but a large quantity of $Pb_3O_4$ also formed on the surface. On the other hand, it was observed that 3BS (tribasic-lead sulface, $3PbO{\cdot}PbSO_4{\cdot}H_2O)$ was the main product on the plate in case of typical curing process with some interval. From the initial current capacity test, the positive plate having 3BS was approximately 40% higher in initial current capacity than that having 4BS. It was concluded that 4BS and $Pb_3O_4$ on the plate surface were harmful to the initial current capacity of lead acid battery.