• Title/Summary/Keyword: current building condition

Search Result 176, Processing Time 0.028 seconds

Concept Design for Measurement against Large Fire Spreading based on BuildingDatabaseofaFolkCultureVillage

  • Umegane, Takuji;Uchida, Daisuke;Mishima, Nobuo;Wakuya, Hiroshi;Okazaki, Yasuhisa;Hayashida, Yukuo;Kitagawa, Keiko;Park, Sun-gyu;Oh, Yong-sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.21-22
    • /
    • 2015
  • This study aims to develop a current building condition database of an important folk culture village of South Korea considering their fire spread risk. We have selected a folk cultral village, and conducted field survey to reveal structure of buildings, materials of building wall, and roof style which make us understand current vulnerability of the village to fire spread. As a result, we made a current building condition database with map, which showed that the village had mixture of reinforced concrete and wood. Besides, we proposed a conceptual idea to prevent from large fire accident in the village.

  • PDF

Establishing Unmanned Aircraft System(UAS)-based Facility Condition Monitoring Process through Benchmarking Analysis (벤치마킹 분석을 통한 무인항공시스템 기반 시설물 상태 모니터링 프로세스 수립 연구)

  • Kwon, Jin-Hyeok;Kim, Sungjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.101-102
    • /
    • 2022
  • The current facility condition monitoring has disadvantages such as a slow inspection cycle, a risk of human casualties, and the need for a lot of time and money as the size of the structure is larger, because human access is required with limited use. Drones can reduce the risk of human casualties due to their good accessibility, and can compensate for the shortcomings of the current method by enabling monitoring on a wide scale. The goal of this study is to provide the current domestic monitoring process through benchmarking according to the recent research case of the US Department of Transportation (DOT) to suggest a process suitable for the domestic situation and the direction of future improvement measures.

  • PDF

The Current Status Analysis and Improvement of Green Building Education through Expert Survey (전문가 인식조사를 통한 녹색건축물 교육 실태분석과 개선방안 연구)

  • Kim, Yong-Gook;Song, Yu-Mi;Cho, Young-Jin
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.2
    • /
    • pp.49-57
    • /
    • 2018
  • The purpose of this study is to analyze the current condition of green building education, which is a necessary condition to activate green architecture, with the need to reduce greenhouse gas emissions in the building sector. The main results are as follows. First, the level of education and the level of domestic green architecture were generally underestimated. Second, in order to increase the satisfaction of participants in green building education, it is necessary to increase the number of courses and to increase the number of lecturers who have excellent practical skills. Third, there is a need to strengthen green building programs related to BEMS and green remodeling. Fourth, it is necessary to expand the education on green architecture for the people in the architectural planning and design field and the related field officials. Fifth, green building education needs to be implemented in conjunction with curriculum of elementary, middle and high school. Sixth, it is necessary to diversify the PR(public relations) channels of the green building education program and to provide a way to give the employment increase point when the curriculum is completed. Seventh, there is a need to expand administrative and financial incentives for green architecture in order to revitalize green architecture education.

A Proposal of Hazard/Risk Assessment Criteria and an Asbestos Management Method for Asbestos-containing Building Materials

  • Park, Wha-Me;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.66-72
    • /
    • 2012
  • Objectives: The AHERA method by the US EPA, ASTM E2356-04, and HSG264 by the UK HSE, all of which are hazard/risk assessment methods for asbestos-containing building materials, were reviewed and compared based on 231 homogeneous areas. In addition, the current Act on Asbestos Safety Management (enforcement: April 29, 2012) was reviewed and analyzed. This trial provided fundamental data for improving the current asbestos hazard/risk assessment method. Methods: For the hazard/risk assessment of 77 asbestos-containing public buildings including schools, 231 homogeneous areas were selected, each of which was assessed using AHERA, ASTM E2356-04, and HSG264. Results: The matching rate of the hazard/risk assessment stood at 20.4 percent between AHERA and ASTM, at 71.4 percent between AHERA and HSG264 and at 17.8 percent between ASTM and HSG264. The AHERA method includes a seven-category rating scale. There were three categories, two of which have three subcategories. ASTM provides two decision-making charts consisting of ten rating scales for current condition estimation and for potential for disturbance estimation. In addition, the HSG264 method has a total of 20 scores with four items, and then provides four grades. This HSG264 method cannot clearly separate current condition and potential for disturbance. Conclusions: In the Korean Act on Asbestos Safety Management, the hazard/risk assessment method for asbestos-containing building materials should consider balance between current condition estimation and the potential for disturbance estimation.

Effect of Moisture on the Current Density for Optimized Cathodic Protection Condition in RC Structures (RC조 구조물의 최적 음극방식 조건 설정을 위한 함수율의 영향에 대한 평가)

  • Park, Dong-Cheon;Cho, Gyu-hwan;Ahn, Jae-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.29-30
    • /
    • 2013
  • Steel corrosion is the most serious problem in RC structures. Even though patch repair method is normally applied in repair system, the effectiveness is not enough. Cathodic protection in active repair method to deteriorated RC structures. FEM model was developed to simulate the optimized cathodic protection condition. Iro oxidation, hydrogen evolution and oxygen reduction were considered to expect current distribution. Moisture content in concrete which can affect the electrolyte conductivity was used as initial condition.

  • PDF

A Study on Analysis of Causes for Fatal Accidents (사망재해의 원인분석에 관한 연구)

  • 백종배;민경일;이영섭
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.56-62
    • /
    • 1990
  • This study is conducted to analyze exact causes of occupational fatalities and results are as follows : 1) The number of fatalities in establislment which employed less than 50 workers is 605(40.1% ). Age of sixties and seventies is occupied by 10 percent with there being old-aged trend. Fatal workers who were employed less than 3 months are 39.5 percent and fatal workers who were employed more than 10 years are 11.9 percent. Safety training is necessary for newly recruited and long employed workers. 2) Accident type is, in sequence, fall from elevation, traffic accident, disease, contact with electric current, and hazardous condition is, in order, inadequate guard, hazardous method or procedure, public hazard, and agency of accident is, in sequence, temporary structure/building/structure, powered transport vehicle, passenger vehicle, hoisting or lifting apparatus, and unsafe act is, in order, driving error, failure to secure or warn. 3) The results of cross-tabulation for hazardous condition and accident type is, in sequence, traffic accident by public hazard, fall from elevation by hazardous method or procedure, fall from elevation as well as contact with elctric current by inadequate guard. The result of cross-tabulation for agency of accident and accident type is, in order, fall from elevation by temporary structure/building/structure, traffic accident of passenger vehicle and powered transport vehicle, contact with electric apparatus. The result of cross-tabulation for agency of accident and hazardous condition is, in sequence, public hazard of passenger vehicle, hazardous method or procedure of temporary structure/building/structure, publit hazard of powered transport vehicle, inadequate guard of temporary structure/building/structure. The result of cross-tabulation for unsafe act and accident type is, in sequence, traffic accident by driving error, fall from elevation by inattention to footing or surrounding, contact with electric current by secure or warn.

  • PDF

A Study on the Ventilation Improvement of Diesel Locomotive Engine Load Test Building using Computational Fluid Dynamics (전산유체역학을 이용한 디젤엔진 부하시험장의 환기 개선에 관한 연구)

  • Park Duckshin;Jeong Byungcheol;Cho Youngmin;Park Byunghyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.227-242
    • /
    • 2005
  • The aim of this study is to relieve the poor ventilation problem of the diesel locomotive engine load test building, located in an urban area. This paper evaluates the ventilation performances of the studied load test building based on the temperature measurement experiment and the computational fluid dynamics (CFD) during the engine load test. The temperature rise caused by the radiator blower of the building was turned out to be the main cause of disturbing the thermal conditions of the building. The indoor temperature distributions simulated by Fluent were validated with the temperature measurement results obtained from the studied building. The simulation results indicated that the comfort condition of this building was poor We suggested several remedial changes in the duct structure of this building for the improvement of the comfort conditions. In addition, a prototype drawing combining several improved design options was proposed. and then the simulation of the temperature distribution in the proposed prototype was performed. The result indicated that the indoor thermal condition of this proposed building was improved when compared with that of the current building.

Automated condition assessment of concrete bridges with digital imaging

  • Adhikari, Ram S.;Bagchi, Ashutosh;Moselhi, Osama
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.901-925
    • /
    • 2014
  • The reliability of a Bridge management System depends on the quality of visual inspection and the reliable estimation of bridge condition rating. However, the current practices of visual inspection have been identified with several limitations, such as: they are time-consuming, provide incomplete information, and their reliance on inspectors' experience. To overcome such limitations, this paper presents an approach of automating the prediction of condition rating for bridges based on digital image analysis. The proposed methodology encompasses image acquisition, development of 3D visualization model, image processing, and condition rating model. Under this method, scaling defect in concrete bridge components is considered as a candidate defect and the guidelines in the Ontario Structure Inspection Manual (OSIM) have been adopted for developing and testing the proposed method. The automated algorithms for scaling depth prediction and mapping of condition ratings are based on training of back propagation neural networks. The result of developed models showed better prediction capability of condition rating over the existing methods such as, Naïve Bayes Classifiers and Bagged Decision Tree.

The Method on Safety and Maintenance Based Domestic Infrastructure Facilities for Survey of Actual Condition (안전 및 유지관리기반 국내 인프라 실태조사 수행 방안)

  • Lee, Jeong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.230-231
    • /
    • 2015
  • Recently, although researching and developing of safety and maintenance on domestic infrastructure facilities in KOREA are important, there has been very little research regarding on a comprehensive and integrated survey of actual condition. Therefore this study asserts the necessity of the survey process of actual condition by period planning(short-term, middle-term, long-term). The purpose of this study is to investigate current situation and to suggest the whole process method, and to establish survey process of actual condition on domestic infrastructure facilities.

  • PDF

Maximum power point tracking method for building integrated PV system (건물용 태양광 컨버터의 최대전력 추종 기법 개발)

  • Yu, Byung-Gyu;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.299-303
    • /
    • 2011
  • This paper proposes a novel sensorless maximum power point tracking (11PPT) algorithm for PV systems. The method is based on dividing the operating time into several intervals in which the PV terminals are short circuited in one interval and the calculated short-current of the PV is obtained and used to determine the optimum operating point where the maximum output power can be obtained. The proposed MPPT algorithm has been introduced into a current-controlled boost converter whose duty ratio is controlled to the maintain MPP condition. The same sequence is then repeated regularly capturing the PV maximum power. The main advantage of this method is eliminating the current sensor. Meanwhile, this MPPT algorithm reduces the power oscillations around the peak power point which occurs with perturbation and observation algorithms. In addition, the total cost will decrease by removing the current sensor from the PV side. Finally, simulation results confirm the accuracy of the proposed method.

  • PDF