A Study on the Physical Property of Epoxy Resin Due to After-Curing Condition (후경화 조건에 따른 에폭시 수지의 물성에 관한 연구)

  • Han, Jeong-Young;Kim, Myung-Hun;Kang, Sung-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.976-981
    • /
    • 2012
  • In this study, hardness, microstructure and temperature of glass transition are measured respectively by using SEM (Scanning electron microscope) and DSC (Differential scanning calorimeter) to analyze the effects on material properties by after-curing in the epoxy resin. As the result of hardness test according to the after-curing conditions, the higher the temperature of after-curing, hardness and heat resistance are, the higher hardness is. As a result of microstructure for each specimen by SEM, it could be confirmed that the specimen with after-curing has more dense fracture surface. It is also found that temperatures of glass transitions by DSC are comparatively higher in the specimens with after-curing, and the differences between after-curing conditions are negligible.

Research for The Comparing Test of the Fracture Strength According to the Heat Curing Method in the Denture Base Resin (의치상용 열중합 레진의 Curing방법에 따른 파절 강도의 비교실험연구)

  • Han, Min-Soo
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • For this study, self curing resin and heat curing resin used for existing usual resin denture base in the denture industry were chosen by manufacturer. Curing tests for 30-minute, I-hour, 2-hour and 3-hour were conducted to know the strength of the resins and conduct analysis to get other necessary information. The results obtained are as follows: 1. Heat curing resins show a little differences among the manufacturers. However 30-minute curing resin shows great difference as shown in the fracture strength test. 2. The effect from the granularity of the resins on the fracture strength was found insignificant which means there is no difference between coherence and strength. 3. To summarize the results from each time level, the longer the time is, the more the minute cracks on the surface, which is the cause of reduced strength. From this test, it was identified that in making the denture base for patients in dental clinics, 30-minute curing is most efficient and effective in reducing discoloration and monomers, although long-time curing has been considered to be the principal.

  • PDF

AN INVESTIGATION ON THE CHARACTERIZATION OF COMPOSITE RESIN POLYMERIZED BY THE USE OF AN ARGON ION LASER (Argon 이온 레이저 중합에 의한 Composite resin의 물성에 관한 연구)

  • Cho, Hyung-Kyung;Lee, Chung-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.69-82
    • /
    • 1992
  • An experimental investigation of the physical properties of light curing composite resin P-50 was performed, in which an argon ion laser beam was irradiated. The physical and mechanical properties of laser polymerized composite resin were determined by measuring the compressive strength, diametral tensile strength, curing depth and microhardness depending upon the experimental conditions such as the laser irradiation time(10sec, 20sec, 30sec) and laser power(300mW, 500mW, 1000mW). These observations were compared with a conventional visible light curing technique. In addition, to evaluate the marginal adaptation, Class V cavity was prepared on the buccal or lingual surface of the extracted premolar and filled with P-50 light curing resin. The test samples were irradiated with both light sources so that the interface between the restoration and the tooth structure were observed under scanning electron microscope. The most of physical and mechanical properties of the laser cured resin showed a remarkable improvement than those treated with the conventional light source, while the observations with the scanning electron microscope provided no significant difference for two polymerized sources. From the results in the experiment it appears that the potential of an argon ion laser is of important value of the use in the polymerization of composite resin.

  • PDF

The Effect of EVA Sheet Gel Content Depending on Curing Condition for Photovoltaic Module (PV모듈용 EVA Sheet의 Curing조건에 따른 Gel Content 특성)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Park, Kyung-Eun;Kim, Hyun-Il;Yu, Kwon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1155-1156
    • /
    • 2006
  • In this paper, we analyzed the effect of EVA Sheet Gel Content depending on curing condition for photovoltaic module. Gel Content was measured by manufacturing Glass/EVA Sheet/Back Sheet scheme at several curing temperature and curing time. And the surface analysis of EVA Sheet depending on process condition could be observed using SEM(Scanning Electron Microscope). Through this experiment, we could confirm that there are differences on Gel Content of EVA Sheet and surface configuration depending on curing temperature and curing time. To find out the optical characteristic dependency on curing condition, Class/EVA Sheet/Glass scheme was fabricated. The optical transmittance of EVA Sheet at visible wavelength was enhanced 5% when compared to Glass/Glass scheme. And the transmittance of $130^{\circ}C$/4min, $110^{\circ}C$/4min, $160^{\circ}C$/6min process condition was higher at ultraviolet wavelength range. These curing conditions could be regarded as the best process for suppression the discoloration speed of EVA Sheet under UV light.

  • PDF

A Study on the Development of Automatic Welding System using Solor Energy (태양에너지를 이용한 자동용접 시스템 개발에 관한 연구)

  • Kim I.S.;Kim O.S.;Son J.S.;Seo J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.532-533
    • /
    • 2006
  • In this research work attempts were made to study the bonding of thermoplastics with adhesives using solar energy. In order to study the curing behaviour necessary experiments were conducted under varying conditions of temperature, exposure time and power. The cured samples were then studied under the optical microscope before subjecting to tensile testing in order to study their mechanical properties. The fracture surfaces were further studied under the Scanning Electron Microscopy in order to study the microstructural changes that are taken place during curing. From the present study it is evident that curing under higher solar energy temperature, generally improves bond strength and quality of the adhesive joints when compared to other modes of curing process expect the microwave curing process.

  • PDF

AN EXPERIMENTAL STUDY ON THE DIMENSIONAL CHANGES OF RELINED DENTURES AND MECHANICAL PROPERTIES AND SURFACE TEXTURES OF SEVERAL RESINS USED IN DENTURE RELINING (수종 레진으로 의치상 조직면 개조시 의치상의 크기변화와 물리적 성질 및 표면상태 비교 연구)

  • Lee, Chang-Han;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.25-41
    • /
    • 1990
  • The purpose of this study was to evaluate and compare the dimensional changes of relined dentures with a light-curing resin, a heat-curing resin, and a direct, hard reline resin. And also to measure the transverse strength, impact strength, surface hardness of the three resins used in relining. The surface textures of three resins also of evaluated by using scanning electron microscope. Through analyses on the data from this study, the following conclusions were obtained. 1. Impact strength of heat-curing resin was highest, and direct, hard reline resin higher, light-curing resin lowest. 2. Transverse strength of heat-curing resin was highest, and direct, hard reline resin and light-curing resin was lower and not signiicantly different. 3. Surface hardness of light-curing resin was lighest, heat-curing resin higher, and direct, hard reline resin was lowest. 4. After storage of the relined dentures for 1 day and 1 week in water at room temperature, linear shrinkage of distance between the reference points in the maxillary base relined with direct, hard reline resin was lowest, and those relined with light-curing resin and heat-curing resin were lower and were not significantly different. 5. After storage for 4 weeks in orator at room tempeature, linear shrinkage of distance between ridge crests of dentures relined with heat-curing resin was highest and that of distance between denture borders was not significantly different. 6. The dimensional changes of relined dentures during storage in water was not significant except those of distance between denture borders relined with light-curing resin at 1 day and 1 week storage in water. 7. At low magnification (x40) of SEM examination, the surface textures of three resins were similar except light-curing resin which had some defects. At high magnification (x200), the surface textures of hard, direct reline resin were smooth with little defects, but those of heat-curing resin and light-curing resin w ere irregular.

  • PDF

Pre-treatment condition and Curing method for Fabrication of Al 7075/CFRP Laminates (Al 7075/CFRP 적층 복합재료 제조를 위한 전처리 조건과 경화방법 연구)

  • 이제헌;김영환
    • Composites Research
    • /
    • v.13 no.4
    • /
    • pp.42-53
    • /
    • 2000
  • A study has been made to establish an optimum condition in the surface treatment and curing method that is important for the fabrication of Al 7075/CFRP laminates. PAA(Phosphoric Acid Anodizing) provided a good adhesive strength and FPL(Sulfuric / Sodium Dichromate Acid Etching) had a similar adhesive strength with PAA. On the other hand, the poor adhesive strength was shown on vapor degrease and CAA(Chromic Acid Anodizing). By using the atomic force microscope(AFM), it was found that the PAA oxide surface obviously had a greater degree of microroughness as compared to vapor degrease, CAA and FPL treated surfaces. These results support the concept of a mechanical interlocking of the adhesive with-in the oxide pores as the predominant adhesion mechanism. In curing methods, the adhesive strength of co-curing method was higher than that of secondary curing method. With respect to stability of specimen shape, the secondary curing method was better than co-curing method. DMA(Dynamic Mechanical Analysis) test revealed $T_g$ in curing times over 60 min is nearly same, so it is estimated they will have similar degree of curing and joint durability in using FM300M adhesive film.

  • PDF

Curing Kinetics and Chemorheological Behavior of No-flow Underfill for Sn/In/Bi Solder in Flexible Packaging Applications

  • Eom, Yong-Sung;Son, Ji-Hye;Bae, Hyun-Cheol;Choi, Kwang-Seong;Lee, Jin-Ho
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1179-1189
    • /
    • 2016
  • A chemorheological analysis of a no-flow underfill was conducted using curing kinetics through isothermal and dynamic differential scanning calorimetry, viscosity measurement, and solder (Sn/27In/54Bi, melting temperature of $86^{\circ}C$) wetting observations. The analysis used an epoxy system with an anhydride curing agent and carboxyl fluxing capability to remove oxide on the surface of a metal filler. A curing kinetic of the no-flow underfill with a processing temperature of $130^{\circ}C$ was successfully completed using phenomenological models such as autocatalytic and nth-order models. Temperature-dependent kinetic parameters were identified within a temperature range of $125^{\circ}C$ to $135^{\circ}C$. The phenomenon of solder wetting was visually observed using an optical microscope, and the conversion and viscosity at the moment of solder wetting were quantitatively investigated. It is expected that the curing kinetics and rheological property of a no-flow underfill can be adopted in arbitrary processing applications.

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF

Study of Optimized Condition for Bend State in Polymer Stabilized Pi-cell with Compensation Films

  • Jeong, Seung-Yeon;Shin, Hyun-Ho;Bos, Phil;Shin, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.589-594
    • /
    • 2003
  • The pi-cell [1] is known as one of the candidates for a fast response time and a good viewing angle characteristics due to a self-compensated configuration and can be a replaceable mode instead of the current TN mode and the IPS mode for moving picture in future. This paper shows the optimized condition to maintain bend state instead of splay state, which is mortal demerit for good optical properties in a pi-cell, by using the polymer stabilized method [2]. The good electro-optical characteristics are also obtained by optimizing the various factors, which are monomer concentration in a LC, UV intensity, curing time, curing voltage, and curing temperature, and by using retardation film. We use a scanning electron microscope to study the structures of the polymer stabilized polymer network in a pi-cell as a key to figure out why bend state is occurred.