• Title/Summary/Keyword: cryostat

Search Result 168, Processing Time 0.028 seconds

Design of 1 MVA Single Phase HTS Transformer with Pancake Windings Cooled by Natural Convection of Sub-cooled Liquid Nitrogen

  • Kim, Woo-Seok;Kim, Sung-Hoon;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won;Han, Jin-Ho;Lee, Don-Kun;Park, Yeon-Suk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.34-37
    • /
    • 2003
  • A 1 MVA single-phase high temperature superconducting (HTS) transformer with BSCCO-2223 wire was designed in this paper. The rated voltages of each sides of the transformer are 22.9 kV and 6.6 kV respectively. Double pancake HTS windings arranged reciprocally will be used for the transformer windings, because of the advantages of insulation and distribution of surge voltage in case of a large power and high voltage transformer. Single HTS wire was used for the primary windings and four parallel wires were used for the secondary windings of the transformer with transposition. A core of the transformer was designed as a shell type core separated with the windings by a cryostat made of GFRP with a room temperature bore. The operating temperature of the HTS windings will be about 65K with sub-cooled liquid nitrogen. A cryogenic cooling system using a GM-cryocooler for this HTS transformer by natural convection of liquid nitrogen was designed. This type of cooling system can be a good option for compactness, efficiency, and reliability of the HTS transformer.

A STUDY OF THERMAL ANALYSIS OF KAONICS (적외선 카메라 KAONICS의 열해석)

  • Kang, Ji-Na;Lee, Sung-Ho;Jin, Ho;Park, Soo-Jong;Moon, Bong-Kon;Kim, Sang-Ho;Park, Jang-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.467-480
    • /
    • 2004
  • It is very important to eliminate thermal background radiation for the near infrared camera system such as KAONICS (KAO Near Infrared Camera System). Thermal background radiations which come from window and cryostat wall influence IR detector and decrease IR system performance. Therefore the cold box which contains optics and detector housing must be cooled down to eliminate thermal background radiation. We carried out quantitative analysis to determine internal cooling temperature to reduce thermal noise in the J, H, Ks, and L bandpass. Additionally, we estimated the incoming heat load and then chose the cryocooler adequate to KAONICS's requirements. The cooling time and the final cooling temperature of the cold box were calculated. These results were also implemented to the system design.

A Method for the Determination of Estrogen Receptor Level in Frozen Sections of Porcine Uterus (냉동절편을 이용한 돼지 자궁내 에스트로겐 수용체의 측정)

  • Yoon, Yong-Dal;Park, Chor-Hong;Lee, Young-Keun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.2
    • /
    • pp.131-138
    • /
    • 1989
  • The present study was designed to develop a new method for the determination of estrogen receptor in porcine uterus using frozen sections. Cryostat sections were incubated with $^3H$-estradiol($^3H$-$E_2$) in the presence or absence of diethylstilbestrol(DES) and the radioactivity of 3H-E2 bound to estrogen receptor(ER) was detected. The level of specific estrogen receptor was determined by Scatchard analysis. The highest ratio of specific binding against total binding was achieved in 3 sec. tions(5mm x 5mm) which was corresponded to lOO${\mu}$/ml protein concentration. Optimal binding was obtained during incubation with $^3H$-$E_2$ for 30 minutes at 23$^{\circ}C$ after treatment of sections with acetone for 20 seconds. Three time-washing of sections was proved to be appropriate for the removal of unbound 3H-E2. 200-fold molar excess of DES was substituted for the binding of $^3H$-$E_2$ to ER sufficiently(binding efficiency of 54.8%). ER was saturated with 4nM of $^3H$-$E_2$ and its dissociation constant was 0.1nM. ER assay using frozen sections(Histological radioreceptor assay, HRRA) was significantly correlated with radioreceptor assay for estradiol(RRA, 0.976 , p

  • PDF

Detector Mount Design for IGRINS

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyoung;Lee, Hanshin;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA) detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL) mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

Design, fabrication and test of a taper-type half-wave superconducting cavity with the optimal beta of 0.15 at IMP

  • Yue, Weiming;Zhang, Shengxue;Li, Chunlong;Jiang, Tiancai;Liu, Lubei;Wang, Ruoxu;Huang, Yulu;Tan, Teng;Guo, Hao;Zaplatin, Evgeny;Xiong, Pingran;Wu, Andong;Wang, Fengfeng;Zhang, Shenghu;Huang, Shichun;He, Yuan;Yao, Zeen;Zhao, Hongwei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1777-1783
    • /
    • 2020
  • As a part of R&D work for the high intensity proton linac of China Accelerator Driven Sub-critical System project, a superconducting half-wave cavity with a frequency of 162.5 MHz and an optimal beta of 0.15 (HWR015) has been developed at Institute of Modern Physics (IMP), Chinese Academy of Sciences. In this paper, the design and test results will be described in detail. We introduced a new stiffening strategy for the HWR cavity, the simulation results show that the cavity has much lower frequency sensitivity coefficient (df/dp), Lorentz force detuning coefficient (KL), and can achieve more stable mechanical properties. The performance of the HWR cavity operated in cryostat will be also reported.

Design and Performance Test of a Direct Cooling Equipment for Hydrogen Liquefaction (수소액화용 직접냉각장치의 설계 및 성능시험)

  • Baik, Jong-Hoon;Kang, Byung-Ha;Chang, Ho-Myung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 1996
  • A direct cooling equipment for hydrogen liquefaction has been developed and tested. A direct cooling equipment consists of a liquefaction vessel, a radiation shield, a cryostat and a GM refrigerator. The cool-down and warm-up characteristics of the liquefaction apparatus have been investigated in detail. It is found that the hydrogen starts to be liquefied in the liquefaction vessel after 45 minutes of cool-down. The cool-down and warm-up tests of helium gas are also performed. The cool-down and warm-up characteristics of helium gas are found to be very different from those of hydrogen gas, since helium is not liquefied under the present operating conditions. When the liquefaction vessel is evacuated, natural convection phenomena of charged gas in liquefaction vessel can be removed. It is seen that the cool-down time of liquefaction vessel is substantially increased in vacuum environment.

  • PDF

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

Quantum Hall Effect of CVD Graphene

  • Kim, Young-Soo;Park, Su-Beom;Bae, Su-Kang;Choi, Kyoung-Jun;Park, Myung-Jin;Son, Su-Yeon;Lee, Bo-Ra;Kim, Dong-Sung;Hong, Byung-Hee
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.454-454
    • /
    • 2011
  • Graphene shows unusual electronic properties, such as carrier mobility as high as 10,000 $cm^2$/Vs at room temperature and quantum electronic transport, due to its electronic structure. Carrier mobility of graphene is ten times higher than that of Silicon device. On the one hand, quantum mechanical studies have continued on graphene. One of them is quantum Hall effect which is observed in graphene when high magnetic field is applied under low temperature. This is why two dimension electron gases can be formed on Graphene surface. Moreover, quantum Hall effect can be observed in room temperature under high magnetic field and shows fractional quantization values. Quantum Hall effect is important because quantized Hall resistances always have fundamental value of h/$e^2$ ~ 25,812 Ohm and it can confirm the quantum mechanical behaviors. The value of the quantized Hall resistance is extremely stable and reproducible. Therefore, it can be used for SI unit. We study to measure quantum Hall effect in CVD graphene. Graphene devices are made by using conventional E-beam lithography and RIE. We measure quantum Hall effect under high magnetic field at low temperature by using He4 gas closed loop cryostat.

  • PDF

Distribution of the neuropeptide Y immunoreactive neurons in the olfactory bulb of striped field mouse(Apodemus agrarius) (야생등줄쥐(Apodemus agrarius) 후각망울의 neuropeptide Y 면역반응세포의 분포)

  • Jeong, Young-gil;Kim, Kil-soo;Jung, Ju-young;Lee, Nam-seob;Lee, Kyeng-youl;Kim, Moo-kang
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.407-416
    • /
    • 1999
  • This study was carried out to investigate the NPY-immunohistochemical characteristics of the olfactory bulb in the striped field mouse(Apodemus agrarius). The animals were anesthesized with thiopental sodium and perfused with 4% paraformaldehyde through left ventricle and aorta. Brains were removed and tranfered 10%, 20% and 30% sucrose. Sections were then cut on a cryostat into $40{\mu}m$-thick. The tissue immunostained with avidin-biotinylated complex method. The main olfactory bulb consisted of seven circumferential laminae : an olfactory nerve fiber layer, a glomerular layer with glomeruli surrounding by periglomerular cells, an external plexiform layer having granule and tufted cells, a mitral cell layer, a narrow internal plexiform layer, a granule cell layer forming several cell rows and a layer of white matter. The accessory olfactory bulb had four layers : an olfactory or vomeronasal nerve fiber layer, a glomerular layer consisting of small glomeruli, a mixed layer not distinguishing the external plexiform/mitral cell/granule cell layers and a granule cell layer. Most of NPY-immunoreactive(NPY-IR) neurons in main olfactory bulb were localized in the deeper portion of granule cell layer, white matter and anterior olfactory nucleus. In addition, some NPY-IR neurons were identified in the external plexiform layer. The shape of NPY-IR neurons of all olfactory bulb were predominant round or oval, sometime multipolar in shape. And most NPY-IR processes were parallel to long axis of white matter. In accessory olfactory bulb, NPY-IR neurons were not found in all region.

  • PDF

First Light Results of IGRINS Instrument Control Software

  • Lee, Hye-In;Pak, Soojong;Sim, Chae Kyung;Le, Huynh Anh N.;Jeong, Ueejeong;Chun, Moo-Young;Park, Chan;Yuk, In-Soo;Kim, Kangmin;Pavel, Michael;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.54.2-54.2
    • /
    • 2014
  • IGRINS (Immersion GRating Infrared Spectrograph) is a high spectral resolution near-infrared spectrograph that has been developed in a collaboration between the Korea Astronomy & Space Science Institute and the University of Texas at Austin. By using a silicon immersion echelle grating, the size of the fore optics is reduced by a factor of three times and we can make a more compact instrument. One exposure covers the whole of the H- and K-band spectrum with R=40,000. While the operation of and data reduction for this instrument is relatively simple compared to other grating spectrographs, we still need to operate three infrared arrays, cryostat sensors, calibration lamp units, and the telescope during astronomical observations. The IGRINS Instrument Control Software consists of a Housekeeping Package (HKP), Slit Camera Package (SCP), Data Taking Package (DTP), and Quick Look Package (QLP). The SCP will do auto guiding using a center finding algorithm. The DTP will take the echellogram images of the H and K bands, and the QLP will confirm fast processing of data. We will have a commissioning observations in 2014 March. In this poster, we present the performance of the software during the test observations.

  • PDF