• Title/Summary/Keyword: crown ratio

Search Result 280, Processing Time 0.027 seconds

Ammonium Ion Binding Property of Naphtho-Crown Ethers Containing Thiazole as Sub-Cyclic Unit

  • Kim, Hong-Seok;Do, Kyung-Soon;Kim, Ki-Soo;Shim, Jun-Ho;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1465-1470
    • /
    • 2004
  • A short and efficient synthesis, solvent extraction and potentiometric measurements of new thiazole-containing naphtho-crown ethers are reported. The naphthalene moiety enhances the ammonium ion selectivity over potassium ion. The selectivity of ${NH_4}^+/K^+$ follows the trend $3\;{\approx}\;2\;>\;1$, indicating that the differences in conformational changes of 2 and 3 in forming ammonium complexes affect little on the resulting ammonium/potassium extraction selectivity ratio. The ammonium ion-selective electrodes were prepared with noctylphenyl ether plasticized poly(vinyl chloride) membranes containing 1-4 the effect of one naphthalene unit introduced on either right (2) or left (3) side of thiazolo-crown ether on their potentiometric properties (e.g., ammonium ion selectivity over other cations, response slopes, and detection limits) were not apparent. However, the ammonium ion selectivity of 1, 2 and 3 over other alkali metal and alkaline earth metal cations is 10-100 times higher than that of nonactin.

A STUDY ON THE MECHANICAL BEHAVIORS OF ABUTMENT TEETH AND SUPPORTING TISSUE OF THE TELESCOPE DENTURE BY THE FINITE ELEMENT METHOD (유한요소법(有限要素法)에 의(依)한 Telescope Denture의 지대치(支臺齒) 및 지지조직(支持組織)의 역학적(力學的) 반응(反應)에 관(關)한 연구(硏究))

  • Kim, Moon-Ki;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.109-122
    • /
    • 1984
  • The purpose of this study was to analyze the magnitude and mode of the stress distribution induced in the supporting alveolar bone and periodontal ligament and, to determine the displacement of abutment teeth and telescope denture base by applying chewing force to the telescope denture quantitatively and qualitatively. Two finite element models of telescope denture that were restored the missing mandibular second molar with two abutment teeth which were constructed. In two different models, parallel and tapering type telescope crowns were constructed. These finite element models of two cases used for these experiment were a two-dimensional mesiodistal section of the mandibular second bicuspid and first molar. Chewing force of 25Kg that was devided in the ratio of 45/155 (29%) in bicuspid and 55/155 (35.5%) in molars was applied to telescope denture and abutment teeth respectively. The displacement of the telescope denture base and abutment teeth and the stress distribution in the periodontal ligament and alveolar bone were analized to investigate the influence of chewing force acting on the telescope denture and abutment teeth. The results were as follows: 1. Abutment teeth displaced mesially and the magnitude of displacement of abutment teeth in vertical direction were more than that of horizontal direction in two cases. The displacement of abutment teeth on the telescope denture treated with tapering type telescope crown were less than that of the parallel type crown. 2. The displacement of the telescope denture base that were treated with parallel type telescope crown were less than that of treated with tapering type telescope crown. 3. The stress induced in the alveolar bone and periodontal ligament on abutment teeth that treated with parallel type telescope crown were more than that of treated with tapering type telescope crown and more stress induced in the alveolar bone than in the periodontal ligament. 4. In the telescope denture, the magnitude of displacement of abutment teeth and stress induced in the periodontal ligament and alveolar bone were within physiologic limit.

  • PDF

Conductance Study on the Characteristics of Solution Containing Crown Ethers and Univalent Cation Perchlorates

  • Lee, Shim-Sung;Park, Sung-Oh;Jung, Jong-Hwa;Lee, Bu-Yong;Kim, Si-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.276-281
    • /
    • 1990
  • The equivalent conductance of univalent cation (potassium, silver, thallium and ammonium) perchlorates in methanol containing 18-membered crown ethers, 18-crown-6 (18C6) and 1,10-dithia-18-crown-6 (DT18C6) were measured at different temperatures. The equivalent conductances of ammonium perchlorate were increased by increasing content of DT18C6 exceptionally, due to more favorable solvations than complexations. From the equivalent conductance changes, the formation constants for 1:1 compmlexes have been determined, and the values of enthalpy and entropy changes have been calculated. The complexations of 18C6 and DT18C6 with the univalent cations under investigation are all exothermic and the ${\Delta}$S values are all negative and no considerable differences around 50 J/ (k mol). The selectivity order of 18C6 is $K^+ > Tl^+ > Ag^+ > NH_4^+$, while that of DT18C6 is $Ag^+ > Tl^+ > NH_4^+ > K^+$. By sulfur substitutions in 18C6 result in significant decrease in stability, but the stability of $Ag^+$-DT18C6 complex are $10^4$ times larger than those of $K^+$. This increase of stabilities for $Ag^+$-DT18C6 complex are primary due to the result of favorable exothermic heat of reaction between the polarizable soft cation and soft sulfur centers. In NMR experiment, the stepwise additions of cation perchlorates into crown ether solutions induced two major spectral changes. First, the resonance all shift down field and the cation induced shifts were linear up to 1:1 cation/crown ratio, above which no further changes were observed. On the basis of these results, it could be concluded that 1:1 complex is formed. Second, the magnitudes of cation induced shifts were different each other in same ligand. By addition of silver ion to the solution of DT18C6, the largest shift of proton peak near the sulfur atom was observed. These effects are also arisen from the results of covalent bonding between "soft-soft" interactions.

A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models (한국 유치 모델에서 유전치 지르코니아 크라운의 형태계측학적 연구)

  • Park, Jungha;Lee, Sangho;Lee, Nanyoung;Jih, Myoungkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-56
    • /
    • 2018
  • The purpose of this study was to provide clinical recommendations for restoration with selection of the most similar zirconia crown by 3-dimensional analysis of the shape of the maxillary primary central and lateral incisors in Korean individuals and prefabricated zirconia crowns. The average shape of the sound maxillary primary central and lateral incisors in 300 children was reproduced by 3-dimensional scanning. Zirconia crowns of 4 manufacturers (NuSmile $ZR^{(R)}$ Crown, Cheng $Crowns^{(R)}$, Kinder $Krowns^{(R)}$, and EZ $Pedo^{(R)}$ Crown) were scanned 3-dimensionally, and coordinates for comparison of the shape were measured to evaluate the similarity between the teeth and crowns. The most similar crowns were selected by comparing the mesiodistal length, crown height, crown shape ratio, distance between the same coordinates of a tooth and crown, the radius of curvature of the labial surface, and the volume. As a result of analysis, Cheng $Crowns^{(R)}$ size 3 and NuSmile $ZR^{(R)}$ Crown size 2 were the most similar crowns in the maxillary primary central and lateral incisors, respectively. Scanning the inner surface of the crowns and evaluating the amount of tooth reduction required suggested that an overall lesser amount of tooth reduction compared to that presented by the manufacturer's guidelines should be performed.

Comparison of Crown Shape and Amount of Tooth Reduction for Primary Anterior Prefabricated Crowns (유전치 기성 크라운의 형태 및 치질 삭제량 비교)

  • Kim, Soyoung;Lim, Youjin;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.64-75
    • /
    • 2019
  • The purpose of this study was to obtain instructions for size selection of prefabricated crown and tooth reduction by 3-dimensional analysis of the size and shape of the maxillary primary central and lateral incisors and prefabricated crowns (celluloid strip, resin veneered stainless steel, and zirconia crowns). The maxillary primary central and lateral incisors of 300 Korean children was scanned with three types of prefabricated crown to create standard three-dimensional tooth models and prefabricated crowns. The shapes of the prefabricated crowns and natural teeth were compared according to four parameters (mesio-distal width, height, labio-palatal width, and labial surface curvature coefficient) and calculated the amount of tooth reduction required for each prefabricated crown. The size 2 resin veneered stainless steel crown, size 1 zirconia crown, and size 2 celluloid strip crown were most similar in shape to the primary central incisor. The size 3 rein veneered stainless steel crown, size 2 zirconia crown, and size 3 celluloid strip crown were most similar to the primary lateral incisor. The amount of tooth reduction was similar in both maxillary primary central and lateral incisors. The incisal reduction was greatest for the zirconia crown. At the proximal surface, the zirconia and celluloid strip crowns required a similar amount of tooth reduction, but more than the resin veneered stainless steel crown. The labial surface reduction was greatest for the zirconia crown. The degree of lingual surface reduction was not significant among the three prefabricated crowns. Among the assessment parameters, mesio-distal crown width was the most important for choosing a prefabricated crown closest to the actual size of the natural crown.

Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

  • Alom, Ghaith;Kwon, Ho-Beom;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.12-23
    • /
    • 2021
  • Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.

Analysis of the Factors Influencing the Mesopore Ratio on the Soil Surface to Investigate the Site Factors in a Forest Stand(I) - With a Special Reference to Coniferous Stands - (산림(山林)의 입지환경인자(立地環境因子)가 표층토양(表層土壤)의 조공극률(粗孔極律)에 미치는 영향인자(影響因子) 분석(分析)(I) - 침엽수림(針葉樹林)을 중심(中心)으로 -)

  • Jeong, Yongho;Park, Jae Hyeon;Kim, Kyong Ha;Youn, Ho Joong
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.314-323
    • /
    • 2001
  • This study aimed to clarify the influencing factors of mesopore ratio on a pore geometry of surface soil in coniferous stands as an index of the water retention capacity. Twenty three factors including site conditions and soil properties were analyzed by spss/pc + for the data collected during March to October of 1993. The factors influencing the mesopore ratio(pF2.7) on the surface soil were as follows; macropore ratio(pF1.6), slope, crown-cover rates, thickness of F layer, organic matter contents, and the growing stock. And influencing factor on the ratio of mesopore in the soil surface was correlated with percentage of amount of clay, soil surface, A and B horizon soil hardness shows high negative significance. Also, multiple regression equations for mesopore ratios of surface soil and surface soil hardness, clear length, growing stock, B horizon of soil hardness, organic matter contents show high significance($R^2$; 0.80). In coniferous stands, it is effective in promoting development on the ratio of mesopore that forest practice for enhancing of the water resource retention capacity should be carried out when the crown-cover rates of stands are more than 80 percentages.

  • PDF

A within-subject comparison of short implants in the posterior region: retrospective study of up to 10 years

  • Segalla, Douglas Blum;Villarinho, Eduardo Aydos;Correia, Andre Ricardo Maia;Vigo, Alvaro;Shinkai, Rosemary Sadami Arai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.172-179
    • /
    • 2021
  • Purpose. This intra-patient retrospective study of up to 10 years evaluated the clinical success and risk factors of 6- and 8-mm long implants and their respective prostheses. Materials and Methods. The sample consisted of patients treated at a Military Polyclinic dental service, who received both 6- and 8-mm long tissue level implants in the posterior region of the same arch. Data were collected from the dental charts, clinical and radiographic exams, self-report of sleep bruxism, measurement of maximum occlusal force, and clinical crown-to-implant (C/I) ratio. Data were analyzed by descriptive and inferential statistics with univariate and hierarchical multivariate models, at the 0.05 significance level. Results. The 30 patients (27 women) had 85 implants and 83 prostheses. Two implants were lost before prosthesis installation (implant survival: 97.6%). Ten events of prosthetic complication (screw tightening loss) occurred in five patients (success rate: 87.9%) in a single moment. Only the variable C/I ratio had a significant effect for repairable prosthesis complication (P<.05). Conclusion. The results suggest that 6- and 8-mm long implants have similar long-term clinical success for implants and prostheses.

Ecology of Crown Gall Disease and Population of Agrobacterium spp. in Vineyard Soils (포도나무 뿌리혹병 발생생태 및 포도 재배포장의 Agrobacterium 속의 밀도 조사)

  • Choi, Jae-Eul;Kang, Sung-Su;Park, Sang-Hun;Park, Mun-Kyu;Park, Tae-Jin;Kang, Hee-Wan
    • Research in Plant Disease
    • /
    • v.14 no.2
    • /
    • pp.90-94
    • /
    • 2008
  • To investigate the severity of crown gall disease on grapevine, the ratio of healthy vs. galled grapevines and the presence of the pathogen of the disease in soil were measured in Korean vineyards. In field and greenhouse cultivations, the crown gall incidence of the cv. Kyoho grapevines was $0.4{\sim}97.9%$ and $1.4{\sim}3.8%$ and those of cv. Campbell Early was $1.2{\sim}2.1%$ and $0{\sim}1.8%$, respectively. The higher populations of Agrobacterium spp. were isolated from soils of grapeveins with crown gall than from soils of noninfected vineyards. Based on the colony shapes and growth on plates, 480 isolates of Agrobacterium spp. from 21 soil samples were collected. Only 13 isolates out of 480 developed the gall on inoculated grapevines.

A Morphometric Study of the Stainless Steel Permanent Molar Crown with Three-Dimensional Scanner (3차원 스캐너를 이용한 대구치용 기성금속관의 형태에 관한 계측학적 연구)

  • Shin, Jonghyun;Lee, Hyeongjik;Jeong, Taesung;Kim, Shin;Kim, Jiyeon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.287-300
    • /
    • 2018
  • The aim of this study was to compare the morphological characteristics of two types of stainless steel permanent molar crowns using three-dimensional scanners and the morphological changes of these crowns after crimping. Two types of stainless steel permanent molar crowns, PO-96 and PERMACROWN were scanned using three-dimensional scanner. Crown size, crown index (ratio of buccolingual diameter to mesiodistal diameter at height of contour), cervical convergency of crown were measured. Stainless steel crowns were crimped and re-scanned with three-dimensional scanner. Morphological changes of stainless steel permanent molar crowns were analyzed. As for the crown index, maxillary PERMACROWN was larger buccolingually and smaller mesiodistally than maxillary PO-96 and mandibular PERMACROWN was smaller buccolingually and larger mesiodistally than mandibular PO-96. Maxillary PO-96 was more convergent to cervical mesiodistally than maxillary PERMACROWN and mandibular PO-96 was more convergent to the cervical mesiodistally, buccolingually than mandibular PERMACROWN. Both types of stainless steel permanent molar crowns showed reduction of cervical circumference after crimping. Two products were morphologically different in crown size, shape and cervical convergence. Although both types of stainless steel permanent molar crowns are pre-contoured type, additional crimping is needed to achieve better marginal adaptation.