• Title/Summary/Keyword: crown area

Search Result 478, Processing Time 0.025 seconds

Reexamination on Materials related to Wolji Palace - East Palace is not the Crown Prince's Palace (월지궁(月池宮) 관련 자료 재검토 - 동궁(東宮)은 태자궁(太子宮)이 아니다 -)

  • Choi, Young Sung
    • (The)Study of the Eastern Classic
    • /
    • no.55
    • /
    • pp.173-192
    • /
    • 2014
  • Through excavation on Anapji Pond from March 1975 to December 1976, it was discovered that the whole area around Anapji Pond had been called East Palace (東宮) since 7th century and that the original name of East Palace was Wolji Palace (月池宮) through excavation in 1980. The excavation proved that the original name of Anapji Pond was 'Wolji.' In academic world, there are many scholars who recognize this place as the Crown Prince's palace for being called East Palace. East Palace (which is read Dong Palace with pronunciation in Korean alphabet) actually is another name for Crown Prince's palace. This place, however, cannot have served as Crown Prince's palace as 'independent, exclusive space.' After 7th century, there were detached palaces in Silla including East Palace South Palace North Palace and Yang Palace other than Jeong Palace in Wolseong. East Palace is a palace located in the east. The palace's name is based on bearing and it does not indicate Crown Prince's palace. This article proves that East Palace cannot have been Crown Prince's palace through newly analyzing materials related to Wolji Palace.

White & Pink Esthetic for Clinical Restoration (심미보철 제작에 필요한 White & Pink Esthetic)

  • Yoo, Ha-Seong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.95-115
    • /
    • 2019
  • To be successful in aesthetic prosthetic treatment, the crown part aesthetic (White Esthetic) and the tissue part aesthetic (Pink Esthetic) must be well controlled. Clinically, white esthetics are the area of dental technicians and pink esthetics are the area of dentists, but a deeper understanding of counterparts can produce more successful results. In this paper, I will briefly describe this process.

FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO THE METHOD OF RESTORATION AFTER ROOT CANAL THERAPY (상악 소구치 근관치료후 수복방법에 따른 응력 분포의 유한 요소 분석)

  • Lee, Chung-Sik;Lee, Jae-Young;Cho, Hyo-Sun
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.339-352
    • /
    • 1996
  • Many dentists have been taken an interest in restoration of severly damaged teeth after endodontic treatment and it is a true that there are lots of studies about it. In these days, although we have used Para-Post, pins, threaded steel post, cast gold post and core, and so on, as a method of restoration frequently, it has been in controversy with the effects of them on the teeth and surrounding periodontal tissue. In this study, we assume that the crown of the upper 1st premolar was severly damaged, and after the root canal therapy, two most common types of restoration were carried out ; 1) coronal-radicular amalgam restoration, 2) after setting up the Para-Post, restore with amalgam core and gold crown. After restoration, in order to present the concentration of stress at internal portion of the tooth and the surrounding periodontal tissue, we doveloped a 2-dimensional finite element model of labiopalatal section, then loaded forces from 2 long perpendicular to the lingual incline of buccal ridge an the middle point, parallel to the long direction axis of tooth at the fossa-were applied. The analyzed results were as follows : 1. Stress of the normal first premolar was concentrated on the most weakest anatomical structure, that is, cervical area, and no stress on the bifurcated area of the canal. 2. Crown restoration after root canal therapy causes large stress concentration on the bifurcated area of the canal. This stress concentration has larger value in case of lateral movement of mandible, and there are decrease in the stress concentration compared with natural tooth. 3. Coronal-radicular amalgam restoration method transports more stress to the tooth structure than restoration using Para-Post. 4. There are more stress concentration around Para-Post in the case of lateral movement, and we have more favo rable result when restored with Para-Post. 5. Generally, stress in the lateral movement is larger than stress in the perpendicular load.

  • PDF

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

THE FRACTURE RESISTANCE AND STRESS DISTRIBUTION OF ALL CERAMIC CROWNS WITH TWO TYPES OF FINISH LINE ON MAXILLARY CENTRAL INCISOR (상악중절치에서 전부도재관의 finish line형태에 따른 파절강도와 응력 분포에 관한 연구)

  • Ki Tae-Seok;Kim Kyea-Soon;Lee Jin-Han;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.405-420
    • /
    • 2003
  • Purpose : The purpose of this study was to compare the fracture resistance of the IPS Empress ceramic crown with 1.0mm width rounded shoulder, which is usually recommended in all ceramic crown. and 0.5mm width chamfer finish lines on the maxillary central incisor. Material and method : After 15 metal dies were made for each group, the IPS Empress all ceramic crowns were fabricated and cemented with resin cement(Bistite resin cement, Tokuyama Soda Co. LTD., Japan) on the metal die. The cemented crowns were mounted on the positioning jig and the universal testing machine(Zwick Z020, Zwick Co. Germany)was used to measure the fracture strength with loading on the incisal edge. And also, three-dimensional finite element stress analysis was used to measure the stress distribution with the various types of the finish lines(1.0mm width rounded shoulder, 0.5mm width chamfer), the loading site(incisal edge, incisal $\frac{1}{3}$) and the type of loading(concentration loading, distribution loading). Results and conclusion : 1. In the fracture resistance experiment according to the finish line, the mean fracture strength of rounded shoulder(876N) and the mean fracture strength of chamfer(882N) did not skew any significant difference between each other(p>0.05). 2. The stress distribution of all ceramic crown in three dimensional finite element analysis showed concentration aspect at loading point and cervical area or labial surface. 3. In metal die, there were no differences in stress distribution between finish lines, but in natural teeth model, chamfer finish line showed higher stress than rounded shoulder finish line. 4. When force was loaded on the incisal edge the stress was concentrated on the incisal edge and the cervical area of labial surface. When force was loaded on the incisal $\frac{1}{3}$, the stress concentrated on the cervical area of labial surface and the cingulum area. 5. Generally, natural teeth model showed higher and various stress than the metal die.

EFFECTS OF DIFFERENT PREPARATION METHODS ON THE MORPHOLOGIC CHANGE OF SIMULATED ROOT CANALS IN RESIN BLOCK (수종 근관형성방법에 따른 레진모형상의 근관형태의 변화)

  • Park, Mi-Hee;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.85-96
    • /
    • 1994
  • In this study, 24 curved resin blocks were prepared by one of the following four methods: 1) Conventional technique using K-flexo files 2) Step-back technique using K-flexo files 3) Crown-down technique using K-flexo files 4) Canal Master instrumentation using Canal Master Resin blocks were sectioned, photographed, and evaluated the mean centering ratio and the mean area of dentin removed before and after the instrumentation. The results were as follows : I. the mean centering ratio 1. In the level 1 and level 3, there was no significant difference in the mean centering ratio. 2. In the level 2, Step-back technique showed the worst mean centering ratio among the tested groups(p<0.001) and there was no significant difference between the other three groups. 3. In the level 4, Canal Master instrumentation and Step-back technique showed better mean centering ratio than the other two techniques(p<0.001) and there was no significant difference between the two techniques. II. the mean area of dentin removed 1. In the level l and level 3, there was no significant difference in the mean area of dentin removed. 2. In the level 2, Canal Master instrumentation removed less dentin than the other three techniques(P<0.01). 3. In the level 4, Crown-down technique removed less dentin than the other three techniques(P<0.05).

  • PDF

Adsorption Characteristic of Rare Earth Metal Ions on 1-Aza-15-Crown-5-Styrene (Hazardous Materials)-DVB Resin (1-Aza-15-Crown-5-Styrene (위험물)-DVB 수지에 의한 희토류 금속 이온들의 흡착 특성)

  • Roh, Gi-Hwan;Kim, Kwan-Chun;Kim, Sun-Hwa;Kim, Joon-Tae
    • Applied Chemistry for Engineering
    • /
    • v.20 no.1
    • /
    • pp.21-27
    • /
    • 2009
  • Resins were synthesized by mixing 1-aza-15-crown-5 macrocyclic ligand attached to styrene (a hazardous material) divinylbenzene (DVB) copolymer with crosslink of 1%, 2%, 5% and 20% by a substitution reaction. The characteristic of these resins was confirmed by the content of chlorine, element analysis, thermogravimetric analysis (TGA), surface area (BET), and IR-spectroscopy. The effects of pH, time, dielectric constant of solvents and crosslink on adsorption of metal ions by the synthetic resin adsorbent were investigated. The metal ion was showed a fast adsorption on the resins above pH 3. The optimum equilibrium time for adsorption of metallic ions was about two hours. The adsorption selectivity determined in ethanol was in increasing order of uranium ($UO_2^{2+}$) > manganese ($Mn^{2+}$) > praseodymium ($Pr^{3+}$). The adsorption was in the order of 1%, 2%, 5%, and 20% crosslink resin and adsorption of resin decreased in proportion to the order of dielectric constant of solvents.

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECTS OF INCISAL REDUCTION AND AXIAL INCLINATION ON UPPER CANINE (IPS Empress 도재관의 파절강도 : 상악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향)

  • Shin Dong-Kuk;Kang Han-Joong;Park Yong-Suck;Park Kwang-Soo;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.30-40
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction (2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper canine. Material and methods. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and the universal testing machine was used to measure the fracture strength. Results. 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest (839N) Crowns of 2.0mm depth and $12^{\circ}$ inclination had the lowest strength (559N). 2. There was no significant difference in the fracture strength by axial inclination in the same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

The Prediction of Landslide Hazard Areas Considering of Root Cohesion and Crown Density (뿌리점착력과 수관밀도를 적용한 토사재해 위험지역 예측)

  • Choi, Won-Il;Choi, Eun-Hwa;Suh, Jin-Won;Jeon, Seong-Kon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.6
    • /
    • pp.13-21
    • /
    • 2016
  • Since the landslide hazard areas prediction was analyzed by slope-angle and soil properties, regional characteristics is not taken. Therefore, in order to make more rational prediction, it is necessary to consider the characteristics of the region. Tree roots have been known to increase soil cohesion in landslide hazard areas and to vary the degrees depending on the tree type. In addition, a reasonable prediction of landslide hazard areas can be made by considering crown density based on crown distribution patterns of the area of interest. In this study, using the roots cohesion considering the crown density of the trees, which is in the landslides risk areas around Mt. Gwehwa in Sejong City, the landslides risk areas were predicted and compared with predicted results obtained by not considering root cohesion.