• 제목/요약/키워드: cross-sectional image

검색결과 296건 처리시간 0.025초

사각관 이상유동 분석을 위한 전기적 캐패시턴스 토모그라피 코드 개발 (Development of an Electrical Capacitance Tomography Code for Analysis of Two-Phase Flow in the Rectangular Pipe)

  • 이경황;이재영
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.87-94
    • /
    • 2005
  • A computer code for Electrical Capacitance Tomography (ECT) is developed to sense the cross sectional phase distribution of two-phase flow in the rectangular pipe in which the tomography sensor furnished by the insulated wall, electrodes, and electric field screen. The computer code had two steps for the image reconstruction. In the forward projection step, the sensitivity matrix was constructed based on the electric field calculated by the finite difference method. In the backward projection step, the sensitivity matrix and the measured capacitances were used to reconstruct the cross sectional image. Several algorithms including LBP, TR, ITR, and PLI were employed to find the proper one for the two-phase flow analysis. Since the dielectric constant of the water in two-phase flow is sensitive to the thermal parameter such as, temperature and pressure, the developed code was evaluated to find their accuracy, speed of calculation, and sensitivity to the variation of the dielectric constant. It was found that the iterative methods are superior to the direct methods for the image reconstruction, and the PLI method was the best in the variation of the dielectric constants.

파랑수역에서 비부력 원형 제트의 거동 (Behavior of Non-buoyant Round Jet under Waves)

  • 유용욱;이종인;김영택
    • 한국해안해양공학회지
    • /
    • 제19권6호
    • /
    • pp.596-605
    • /
    • 2007
  • 본 연구에서는 파랑이 존재하는 수역에서 수평방향으로 분사되는 비부력 원형 난류제트의 거동을 검토하기 위해 수리실험을 수행하였다. 난류제트의 유속은 PIV(particle image velocimetry)기법을 이용하여 측정하였으며, 측정된 순간유속장을 위상평균하여 평균유속장으로 계산하였다. 수리실험에서는 상대적으로 작은 파고의 규칙파가 사용되었으며, 파랑의 분산이 난류제트의 확산현상에 미치는 영향을 제트의 중심선유속과 횡단면유속의 변화를 통하여 관찰하였다. 또한 파랑의 위상변화에 따른 제트 거동을 파악하기 위하여 다른 세 위상순간에서 제트의 거동을 비교하였다. 제트의 중심선유속은 파고가 커짐에 따라 감소하였으며, 횡단면의 폭은 증가함을 알 수 있었다. 제트의 횡단면유속분포 특성인 자기상사성은 파고가 증가할수록 약해졌으나 축방향으로의 단면폭의 변화는 크지 않았다. 또한 파고에 대한 제트의 변화에 비해 파랑 위상에 대해서는 변화가 작음을 알 수 있었다.

간호사의 이미지와 호감도 분석 (Analysis of the Image and Likability of the Nurse)

  • 염영희;김경희;손희숙;전재희;이정민;김명애
    • 임상간호연구
    • /
    • 제21권2호
    • /
    • pp.169-179
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate nurse images and likability that were perceived by various groups in the general population. Methods: Using cross-sectional descriptive design, six groups of people were invited to participate in the survey. The participants included nurses, physicians, nurse aids/technicians, patients/caregivers, college students, and the general public. A total of 1,530 individuals were drawn from 42 hospitals nationwide. Bhargava's likability questionnaires and the Ward Nurse Image tool were used. Results: Compared with other groups, patients and caregivers had higher scores for likability and better nurse image than other groups. Most respondents perceived nurses are clean and caring, but many individuals still had the image that nurses are submissive. Conclusion: To improve nurse image, perceptions from various groups of people need to be considered and programs develop to show the positive aspects of nursing and nurses.

영상 처리 기법과 B-spline 근사화를 이용한 단면영상의 3차원 재구성 (3D Shape Reconstruction of Cross-sectional Images using Image Processing Technology and B-spline Approximation)

  • 임오강;이진식;김종구
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.93-100
    • /
    • 2001
  • The three dimensional(3D) reconstruction from two dimensional(2D) image data is using in many fields such as RPD(Rapid Product Development) and reverse engineering. In this paper, the main step of 3D reconstruction is comprised of two steps : image processing step and B-spline surface approximation step. In the image processing step, feature points of each cross-section are obtained by means of several image processing technologies. In the B-spline surface approximation step, using the data of feature points obtained in the image processing step, the control points of B-spline surface are obtained, which are used for IGES file of 3D CAD model.

  • PDF

광섬유를 이용한 광영상단층촬영기 제작에 관한 연구 (A Study on Optical Coherence Tomography System by Using the Optical Fiber)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.34-40
    • /
    • 2004
  • 본 연구에서는 인체에 무해하며, 고분해능 측정과 저가격화 및 소형으로 제작이 가능한 광섬유를 이용한 광영상단층촬영기 제작에 관한 것이다. 시스템의 기본원리는 마이켈슨 간섭계를 이용한 것으로서 광섬유를 이용하여 간섭계를 구성하였다. 시스템의 구성으로는 광원은 분해능 및 측정범위를 고려하여 1,300(nm) 중심파장을 가지며 대역폭이 35(nm)인 상용제품의 SLD(Superluminersent diode)를 사용하였으며, 샘플내부의 영상을 검출하기 위한 간섭신호 검출방법은 기준거울이 선형적으로 이동하여 광경로를 일치하는 광지연선로를 구성하였다. 그리고 간섭계는 단일모드 광섬유를 이용하여 마이켈슨 간섭계를 구성하였으며, 스캐너는 시준기를 이용하여 샘플에 대한 초점을 고정하였으며, 스텝모터를 이용하여 샘플에 대한 횡단방향의 이동을 통해 샘플의 2차원 단층영상을 측정하도록 하였다. 수광부는 소신호인 간섭신호를 검출하기 위하여 감도가 뛰어나면 잡음특성이 우수한 800-1,700(nm) 측정범위의 광검출기를 사용하였다. 신호처리부에서 간섭신호의 포락선 신호만을 검출하기 위하여 증폭 및 필터링 하여 A/D 변환을 거친 후 영상검출 프로그램을 통해 실시간으로 단층영상을 나타내도록 하였다. 측정결과 분해능은 약 30($\mu\textrm{m}$)로서 이론식과 일치함을 확인하였으며, 샘플을 이용한 단층촬영에서 실시간으로 양파조직의 조직형태를 측정하였다.

단층진단법을 이용한 축대칭 부분예혼합 화염의 자발광 스펙트럼 해석에 관한 연구 (Tomographic Interpretations of Visible Emissions from the Axisymmetric Partially Premixed Flames)

  • 하광순;최상민
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.769-776
    • /
    • 2000
  • Visible spectral characteristics of cross-sectional emissions from a partially premixed methane/air and propane/air flames have been investigated. An optical train with a two-axis scanning mirror system was used to record line-of-sight emission spectra from 354nm to 618nm, and inversion technique was adapted to obtain cross-sectional emission spectra. By analyzing the reconstructed emission spectra, cross-sectional intensities of CH and $C_2$ radicals were separated from the background emissions. The blue flame edge and yellow flame edge were also obtained by image processing technique for edge detection with color photograph of flame. These edges were compared with radial distributions of CH, $C_2$ radicals and background emissions. The CH radicals were observed at blue flame edge. The background emissions were generated by soot precursor at upstream of flame and by soot at downstream of flame. The $C_2$ radicals in propane/air flame were observed more than those in methane/air flame.

주파수 변조 분사가 횡단 유동장의 분무 특성에 미치는 영향 (Spray Characteristics of Modulated Liquid Jet Injected into a Subsonic Crossflow)

  • 이민철;김종현;구자예
    • 한국분무공학회지
    • /
    • 제14권2호
    • /
    • pp.59-64
    • /
    • 2009
  • These experiments are close examination of spray characteristics that are continuous liquid jet and modulated liquid jet. The experiments were conducted using water, over a range of crossflow velocities from $42{\sim}l36\;m/s$, with modulation frequencies of $35.7{\sim}166.2\;Hz$. Between continuous crossflow jet and modulated cross-flow jet of penetration, breakup point, spray angle and macro spray shape are experimentally investigated with image analysis. In cross-flow field, main parameter of liquid jet for breakup was cross-flow stream rather than modulation effect. As oscillation of the periodic pressure that could make liquid jet moved up and down, the mixing efficiency was increased. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. So, this phenomenon has a good advantage of mixing spray from concentration of center area to outer area. Because of modulation frequency, SMD inclination of the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. Then cross-sectional characteristics of SMD size were about same tendency over a range that is effect of spray mixing. The tendency of volume flux value for various modulation frequency was same distribution. And volume flux was decreased when the modulation frequency increase.

  • PDF

Depression, sleep quality, and body image disturbances among pregnant women in India: a cross-sectional study

  • Kranti S. Kadam;Aditya R. Anvekar;Vishnu B. Unnithan
    • Journal of Yeungnam Medical Science
    • /
    • 제40권4호
    • /
    • pp.394-401
    • /
    • 2023
  • Background: Pregnancy is associated with a number of physical, emotional, and biological changes that can exacerbate maternal psychological disturbances, such as body image concerns and depression. Sleep disturbances during pregnancy can also have adverse impacts. This study aimed to determine the prevalence of depression, sleep disturbances, and body image concerns among pregnant women. The study also examined the relationship between these factors and pregnancy-related variables, such as bad obstetric history and whether the pregnancies were unplanned. Methods: A cross-sectional study of 146 pregnant patients was conducted at a tertiary care center over 15 months. The patients were administered the Beck Depression Inventory, Pittsburgh Sleep Quality Index, and Body Image Concern Inventory questionnaires. Contingency tables, Fisher exact test, and Spearman correlation were used to identify underlying relationships. Results: The prevalence of depression was 22.6%. Although body image disturbance was noted in only 2.7% of patients, 46.6% had poor sleep quality. Poor sleep was associated with primigravida status. Bad obstetric history and unplanned pregnancy were associated with depression. Depression was found to be significantly correlated with body image disturbances and poor sleep quality. Conclusion: Psychiatric disorders were prevalent during pregnancy. This study highlights the importance of screening for depression in pregnant patients. Counselling and caregiver education can be useful for mitigating psychological disturbances. Management of pregnancies by multidisciplinary teams that include psychiatrists could be immensely useful in improving the pregnancy experiences of patients.

재활 초음파 영상을 이용한 젊은 성인의 하지 근 구조 비교: 서울과 하노이 하지 근 단면적비교 연구 (Comparison of Muscle Architecture of Lower Extremity using Rehabilitative Ultrasound Image in Young Adults: a Comparative Study of Muscle Cross-sectional area of Lower Extermity of Seoul and Hanoi in Vietnam)

  • 이황재;김민규;하현근;이완희
    • The Journal of Korean Physical Therapy
    • /
    • 제26권5호
    • /
    • pp.324-330
    • /
    • 2014
  • Purpose: The aim of the current study was to compare the muscle architecture of lower extremity using rehabilitative ultrasound imaging (RUSI) in young adults in Seoul and Hanoi. Methods: The study design was a comparative study of muscle cross-sectional area of lower extremity. Sixty healthy young subjects (Seoul group: 30, Hanoi group: 30) participated in this study. Real-time B-mode RUSI with a 7.5MHz linear transducer was used for measurement of cross-sectional area, pennation angle, and muscle thickness of the rectus femoris, tibialis anterior, and medial gastrocnemius muscles. Independent t-test was used for statistical analysis. Results: Significant difference in cross sectional area of rectus femoris was observed between Korean young adults and Hanoi young adults (p<0.01). Muscle thickness and pennation angle of tibialis anterior in Korean young adults were greater than in Hanoi young adults (p<0.01). In addition, the muscle thickness and pennation angle of the medial part of gastrocnemius muscle were greater in Korean young adults than in Hanoi young adults (p<0.01). In addition, in the results for gender, men had larger muscle architectures than women in both groups (p<0.01). Conclusion: This study, using RUSI, showed significant difference in muscle architectures of lower extremity in a diverse group of young adults RUSI.

Magnetic Resonance Imaging Assessment of Paraspinal Muscles in Dogs with Intervertebral Disc Herniation

  • Ye-Jin Kim;Ju-Yeong Kim;Ah-Won Sung;Hyun-Ju Cho;I-Se O;Ho-Jung Choi;Young-Won Lee
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.334-341
    • /
    • 2022
  • A decrease in the paraspinal muscle cross-sectional area (CSA) and functional cross-sectional area (FCSA) are associated with low back pain and disc herniation in humans. This study examined whether chronicity or lateralization of disc herniation affects the CSA and FCSA of the paraspinal muscles. The CSA and FCSA of the paraspinal muscles between the 12th and 13th thoracic vertebrae were measured in 31 dogs with intervertebral disc herniation (IVDH). The muscle CSA and FCSA were evaluated by dividing the values of the body weight, spinal disc CSA, and spinal canal CSA to offset the differences in body type between subjects. In the chronic IVDH group, the ratio of the paraspinal muscle CSA divided by the body weight was significantly lower, and fat infiltration in the paraspinal muscle was significantly higher than in the acute group. The lateralization of the disc herniation was significantly related to the changes in the paraspinal muscle CSA. In the right-sided disc herniation group, right epaxial muscle CSA was significantly reduced compared to the left-sided disc herniation group. The change in the paraspinal muscle might be a helpful indicator to localize less obvious disc pathologies and target the search for the pathology responsible for disc-related symptoms in dogs.