• Title/Summary/Keyword: cross-section

Search Result 4,762, Processing Time 0.033 seconds

An Empirical Analysis of the Effect of Energy Saving Investment on the Improvement of Energy Intensity in Korean Manufacturing (한국 제조업에 대한 에너지절약 투자의 에너지 원단위 개선효과 분석)

  • Park, Changsuh;Yoo, Dongheon
    • Environmental and Resource Economics Review
    • /
    • v.16 no.3
    • /
    • pp.485-510
    • /
    • 2007
  • The purpose of this paper is to empirically analyze the economic effect of energy saving investment on the improvement of energy intensity. The data used in this paper are panel data, both time-series and cross-section data. In addition, eight manufacturing sectors has been divided into two groups: massive energy consuming (four industries) and non-massive energy consuming (four industries) ones and the time period of analysis is from 1982 to 2004. According to the empirical results, firstly, energy saving investment has a negative relationship with energy intensity, however, its effect is not high in terms of absolute volume of energy consuming. Secondly, in improving energy intensity of energy saving investment, its elasticity IS higher in non-massive energy consuming sector compared it with massive energy consuming sector. Thirdly, automation investment is also playing an important role in energy conservation. The elasticities of automation investment to energy intensity are larger than those of energy saving investment. In terms of the reduction of greenhouse gas per investment unit cost, however, energy saving investment has larger effect than automation investment.

  • PDF

Landform and Drainage Analysis in Geoje-Do Using GIS (GIS를 이용한 거제도 지형 및 하계 분석)

  • Kim, Woo-Kwan;Lim, Yong-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.2
    • /
    • pp.19-35
    • /
    • 1997
  • The purpose of this study is to find out the characteristics of landform in Geoje-Do using GIS and DTED data. The characteristics of landform in Geoje-Do are as follows; First, the height-range of Geoje-Do is $0{\sim}580m$, and the average elevation of it is 124m. Volcanic and granite region is mainly appeared at high elevation-region. But, we can't find out outstanding difference of elevation, according to its geology. The second. the slope-range of Geoje-Do is $0{\sim}52$ degree, and the average slope of it is 17.6 degree. The slope of volcanic and granite area is more steeper than any other region. But the results of analysis of the geology in Geojo-Do, don't show outstanding difference of the slope. The third, the area-rate of the aspect of Geoje-Do is almost same in all direction. And the area-rate of south-west direction is the highest. According to the geology of Geoje-Do, granite is distributed the most widely, and the area of volcanic and granite occupy 60% of entire island's area. According to analysis of influence of geology with elevation, geology has little relationship with elevation. According to analysis of geology and drainage network, streams are inclined to be developed well in Alluvium area. Drainage network is well developed throughout the entire island, except southeast area. The highest order of stream is 4 in 1:25,000 topographic map. The density of stream in Geoje-Do is very high, such as 1.6. The bifurcation-ratio of stream is also higher than 4 in all order. The length-ratio of stream is ranged from 1.24 to 3.25. According to the relationship between order and elevation. order is the greater, elevation is the lower. According to the relationship between order and slope, order is the greater, slope is the gentler. In this study, we use DTED Data, and compare it with topographic map data. According to the comparison, there is a little difference between DTED data and topographic map data. Therefore, to use DTED data in landform analysis, it is required coordinate matching process. This process is very important, and take very long time. Thus, if you use DTED in landform analysis, some processes are required. DTED data can be taken very easily, but its using is not simple. Because coordinate adjust is very hard work.

  • PDF

An Analysis of the Characteristics of Paint for Preservation of Painted Works Exhibited in the Outdoor Sculpture Parks: Focusing on the Works Installed in Sculpture Parks in Jeollabuk-do Area (야외 조각 공원 전시 페인팅 작품의 보존을 위한 도료 특성 분석: 전북 지역 조각 공원 설치 작품 중심으로)

  • Oh, Seung-Jun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.36 no.5
    • /
    • pp.383-392
    • /
    • 2020
  • This study aimed to examine the characteristics of paint used for modern art works by conducting sectional observations, inorganic component analysis, and infrared spectroscopic analysis on the painted layers of 3 painted sculpture works exhibited in the Yongdam Dam Environmental Sculpture Park and Naejangsan Sculpture Park in the Jeollabuk-do area. The observations indicate that the cross section is composed of various layers of 2-3 folds, the thickness of the layers was uneven at approximately 23-150 ㎛, and putty was used for plate treatment prior to painting. Inorganic component analysis results show that putty containing calcium carbonate, iron oxide, diatomite, and titanium dioxide was used for the putty layer. It is also assumed that paint mixed with green (Cr2O3), blue(sodaliteblue), red(chromered), andwhite(TiO2) colors were used for the painted layers. As a result of infrared spectroscopic analysis to confirm the types of paint, it is estimated that the paint was mixed with polyester resin and an extender.

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책)

  • Kwon, Soon-Tae;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.189-197
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the interference of Mie scattering, which is main obstacle of the measuring concentration with Rayleigh scattering, a hardware filter was installed for reducing the number density of particles. Furthermore a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. In addition, background noisy was reduced by adjusting the optical array and applying the pin hall and beam trap. The results show that LRS can provide useful information about concentration field and the software filter is very effective method to remove Mie interference.

Satisfaction with Health Care in North Korea: A Study of North Korean Refugees in China (중국내 북한이탈주민을 통해 본 북한의료이용 만족도)

  • Kim, Gae-Young;Chung Woo-Jin;Lee, Yun-Hwan;Park, Chong-Yon;Robinson W. Courtland;Lee, Myung-Ken;Lee, Og-Cheol;Burnham Gilbert M.
    • Health Policy and Management
    • /
    • v.16 no.4
    • /
    • pp.48-67
    • /
    • 2006
  • The aim of the study was to examine levels of satisfaction with health care in North Korea and to identify factors associated with it using a convenience sample of North Korean refugees in China. Data from the 2004 Survey of Health Seeking Behavior of North Korean Households conducted by the Center for Refugee and Disaster Response, Johns Hopkins Bloomberg School of Public Health were used. The study subjects were 273 North Korean refugees whose length of stay in China was less than 3 months. Factor analysis was used to extract factor dimensions from the 12 satisfaction items. Bivariate (t test and ANOVA) and multiple regression analyses were used in examining factors associated with satisfaction with health care use in North Korea Overall, satisfaction level was low ($2.36{\pm}0.36$, score range: 1-5). Of the three-factor dimensions, physician skills scored the highest $(2.93{\pm}0.36)$, followed by drug availability $(2.51{\pm}0.07)$ and general cleanliness $(1.66{\pm}0.55)$. In the multiple regression analysis, having a usual source of care was significantly associated with patient satisfaction. Respondents who identified primary care (section) doctors as their usual source of care tended to be less satisfied than those with the city or county hospital as their usual source of care. County residents tended to report a lower degree of satisfaction with general cleanliness than city residents. Among socioeconomic characteristics, the number of household assets positively predicted satisfaction with drug availability. North Korean residents appear to be dissatisfied with their medical care. It may reflect some inadequacies in the North's universal health care system to meet the healthcare needs of its people.

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Aeroelastic Tailoring of a Forward-Swept Wing Using One-dimensional Beam Analysis (1차원 보 해석을 활용한 전진익 항공기의 복합적층 날개 공력탄성학적 테일러링)

  • Choi, JaeWon;Lim, ByeongUk;Lee, SiHun;Shin, SangJoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.8
    • /
    • pp.555-563
    • /
    • 2020
  • Foward-swept wings are known to possess superior aerodynamic performance compared to the conventional straight wings. However major concerns regarding forward-swept wings include divergence at lower airspeeds which require careful consideration at the design stage. As an endeavor to overcome such drawbacks, aeroelastic tailoring is attempted. In order to find an optimal ply sequence, recursive aeroelastic analyses is conducted and one-dimensional beam analysis coupled with simple aerodynamics is used for the improved computational efficiency and modelling convenience. The analysis used in this paper, DYMORE and analytic formula, both use one-dimensional beam model for the structure. Cross-sectional analysis for multi-cell NACA0015 airfoil section is conducted using VABS and oblique function is used for the sweep angle. Throughout the present aeroelastic tailoring, the maximum divergence speed of 290.2m/s is achieved which is increased by approximately 43% than that for the conventional ply configuration.

Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC (고강도 강섬유보강콘크리트를 적용한 프리캐스트 바닥판 이음부의 구조성능 평가)

  • Lee, Han-Joo;Chung, Chul-Hun;Shin, Dong-Ho;Park, Se-Jin;Kim, In-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.196-205
    • /
    • 2017
  • In precast deck system, structural performance and serviceability are mostly determined by the connection methods between the precast decks. This study proposes precast deck system with asymmetric ribbed connection details using High Strength Fiber Reinforced Concrete(HSFRC) with filler. To verify the proposed method, the flexural performance experiment was carried out with variation of joint cross section type and splice rebar details. From the test results, regardless of joint details, spliced tensile rebars of specimens were deformed to yielding strain level. Also, all types of specimens resulted in sufficient flexural performance. These test results show that the minimum lap splice length specified in current Korea Highway Bridge Design Code is conservative for precast deck joint using HSFRC. Therefore, splice details can be simplified and joint width can be reduced by using HSFRC with filler between the precast decks, and the proposed precast deck systems can be applied to the connection part of precast decks effectively.

Analysis of the Melting Characteristics of a Blade Type Fuse Used for Vehicles Due to Overload (과부하에 따른 차량용 블레이드형 퓨즈의 용단특성 해석)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.38-43
    • /
    • 2010
  • The purpose of this study is to secure the basis for judgment on the cause of an accident by analyzing the melting characteristics of a blade type fuse used for vehicles due to overload. In order to increase the reliability of the test, it was conducted by connecting the electrical system with conditions similar to those of an actual vehicle to apply the load. Carbonization pattern experiment of fuse by outside flame applied Korean Standard (KS). The fuse melted by the overcurrent showed a smooth cross-section while the test terminals, clear plastic body, etc., burnt out by the external flame was badly deformed. When 185% of the rated current (27.8A) was applied to a cable of 15A rated current onto which an over-capacity fuse (20A) was installed, the fuse melting time was 217 seconds. In addition, when a load current of 28.8[A] (139%) was applied, the fuse's test terminal and terminal blade were not burnt out although foam was observed on some parts of the plastic body. When a load capacity of 28.2[A] (141%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melting time was approximately 10 seconds. When a load current of 35.8[A] (119%) was applied, the fuse's test terminal and terminal blade were not burnt out, although some parts of the plastic body was swelled. However, it was observed that the switch terminal melted if approximately six minutes lapsed under such conditions. When a load capacity of 39.4[A] (131%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melted in approximately 69 seconds, and the test terminal and terminal blade were not burnt.

An Analysis on the Behavior Characteristics of the Side of Drilled Shafts in Rocks (암반에 근입된 현장타설말뚝의 주면부 거동특성 분석)

  • Lee, Hyukjin;Lee, Hyungkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.6
    • /
    • pp.101-111
    • /
    • 2006
  • In case of drilled shafts installed by drilling through soft overburden onto a strong rock, the piles can be regarded as end-bearing elements and their working load is determined by the safe working stress on the pile shaft at the point of minimum cross-section or by code of practice requirements. Drilled shafts drilled down for some depth into weak or weathered rocks and terminated within these rocks act partly as friction and partly as end-bearing piles. The base resistance component can contribute significantly to the ultimate capacity of the pile. However, the shaft resistance is typically mobilized at considerably smaller pile movements than that of the base. In addition, the base response can be adversely affected by any debris that is left in the bottom of the socket. The reliability of base response therefore depends on the use of a construction and inspection technique which leaves the socket free of debris. This may be difficult and costly to achieve, particularly in deep sockets, which are often drilled under water or drilling slurry. As a consequence of these factors, shaft resistance generally dominates pile performance at working loads. The efforts to improve the prediction of drilled shaft pile performance are therefore primarily concerned with the complex mechanisms of shaft resistance development. In this study, the numerical analyses are carried out to investigate the behavior characteristics of side of rock socketed drilled shafts varying the loading condition at the pile head. The difference of behavior characteristics of side resistance is also evaluated with the effects of modelling of asperity.

  • PDF