• Title/Summary/Keyword: cross-resistance

Search Result 1,276, Processing Time 0.033 seconds

Estimation of Maneuverability of Underwater Vehicles with Ahead Propeller by the Vertical Planar Motion Mechanism Test (VPMM 시험을 통한 선수부에 프로펠러를 갖는 수중운동체의 조종성능 추정)

  • Shin, Myung-Sub;Kim, Dong-Hwi;Kim, Yagin;Hwang, Jong-Hyon;Baek, Hyung-Min;Kim, Sung-Jae;Park, Sang-Jun;Choi, Young-Myung;Park, Hongrae;Kim, Eun-Soo
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.168-178
    • /
    • 2022
  • In this study, the resistance test, the vertical static angle of the attack test and VPMM test will be conducted to estimate the maneuverability of underwater vehicles with ahead propeller. The vertical static test will be conducted within the range of -40deg to 40deg, to investigate the cross-flow drag at high incidence angles. The tests will be conducted by dividing the propeller rotation into a case in which the propeller rotates at a specific rpm, and a case in which the propeller rotates naturally, according to the towing speed. Hydrodynamic coefficients of vertical direction will be estimated by the captive model tests. Additionally, the vertical dynamic stability index based on estimated hydrodynamic coefficients will be calculated and the impact of the propeller revolution state on the index will be investigated. The results are expected to be used as reference test data for underwater vehicles with ahead propeller.

Analysis of High-Temperature Corrosion of Heat Exchanger Tubes in Biomass Circulating Fluidized Bed Boiler (바이오매스 순환유동층 보일러의 열교환기 고온 부식 특성)

  • Yujin Choi;Dal-hee Bae;Doyeon Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.419-425
    • /
    • 2023
  • This paper presents the research results of analyzing the high-temperature corrosion characteristics of three currently commercialized heat exchanger tube materials under actual operating conditions of a biomass power plant. In order to precisely analyze the high-temperature corrosion characteristics of these materials, a high-temperature corrosion evaluation device was installed in the power plant equipment, which allows for adjusting the surface temperature of the heat exchanger tubes. Experiments were conducted for approximately 300 hours under various temperature and operating conditions. In this study, the commercialized heat exchanger tube materials used were SA213T12, SA213T22, and SA213T91 alloys. In order to objectively analyze the high-temperature corrosion characteristics of each material, an international standard-based process to remove corrosion products was applied to obtain the weight change of the specimens, and the average thickness loss and corrosion rate were derived. Thus, the high-temperature corrosion results for each condition were quantitatively compared and analyzed. In addition, in order to increase the reliability of the high-temperature corrosion evaluation method introduced in this study, the surface and cross-sectional corrosion of the specimens were confirmed by using scanning electron microscopy and energy-dispersive X-ray analysis. Based on these analysis results, it was found that the corrosion resistance of the commercial heat exchanger materials increases as the content of chrome and nickel in the composition increases. Additionally, it was found that the corrosion phenomenon is rapidly accelerated as the surface temperature increases. Finally, the replacement period (lifetime) of the heat exchanger tubes under each condition could be inferred through this study.

Assessment of physical condition of old large Chionanthus retusus(Chinese Fringe Tree) using structural stability analysis (천연기념물 이팝나무 노거수 구조안정성 진단을 통한 물리적 생육상태 평가)

  • SON Jiwon;SHIN Jinho
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.118-130
    • /
    • 2023
  • Decay or large cavities inside trees are the main causes of trees overturning and broken branches, and structurally weakened trees are more vulnerable to strong winds and heavy snowfall. Recently, as strong winds and typhoons increase due to climate change, the damage to human life and property due to trees overturning continues to increase, and cultural assets are in a similar situation. In particular, old big trees are structurally vulnerable to external shocks such as strong winds and heavy snowfall. This study was aimed at providing a scientific basis for preventive protection measures by conducting a structural stability diagnosis of seven retusa fringe trees designated as natural monuments. For the structural stability diagnosis, tree risk assessment and internal tree defect measurements were performed. As a result of the tree risk assessment, the Retusa Fringe Trees in Sinjeon-ri, Yangsan and Gwangyangeupsu had the highest risk of broken branches due to weak branch attachment strength. As a result of the diagnosis of internal defects of cross sections of measured trees, there were suspected cavities or severe decay in all except two trees of the population of Retusa Fringe Trees in Pyeongji-ri. Natural disasters due to climate change are increasing, and the scale is getting larger, so it is very important to preemptively manage large old trees through scientific structural safety diagnosis to manage trees that are vulnerable to environmental changes.

Corrosion Behavior and Ultrasonic Velocity in RC Beams with Various Cover Depth (다양한 피복두께를 가진 RC 보의 부식 거동 및 초음파 속도)

  • Jin-Won Nam;Hyun-Min Yang;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.184-191
    • /
    • 2023
  • With increasing corrosion in RC (Reinforced Concrete) structures, cracks occurred due to corrosion products and bearing load resistance decreased. In this study, corrosion was induced through an accelerated corrosion test (ICM: Impressed Current Method) with 140 hours of duration, and changes in USV (Ultra-Sonic Velocity), flexural failure load, and corrosion weight were evaluated before and after corrosion test. Three levels of cover depth (20 mm, 30 mm, and 40 mm) were considered, and the initial cracking period increased and the rust around steel decreased with increasing cover depth. In addition, the USV linearly decreased with decreasing cover depth and increasing amount of corrosion. In the flexural loading test, the bending capacity decreased by more than 10% due to corrosion, but a clear correlation could not be obtained since the corrosion ratio was small, so that the effect of slip was greater than that of reduced cross-sectional area of steel due to corrosion. As cover depth increased, the produced corrosion amount and USV changed with a clear linear relationship, and the cracking period due to corrosion could be estimated by the gradient of the measured corrosion current.

Effects of Neuromuscular Electrical Stimulation on Muscle Wasting with Cancer Patient: A Systematic Review (신경근전기자극치료가 암 환자의 근육 손실에 미치는 영향: 체계적 문헌고찰)

  • Eun Soo Park;Jong Hee Kim;Soo Dam Kim;Dong Hyun Kim;Eun Jung Lee;Min Seok Oh;Hwa Seung Yoo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.15-29
    • /
    • 2023
  • Objectives The purpose of this study is to systematically review the effects of Neuromuscular Electrical Stimulation treatment on muscle wasting in cancer patients. Methods Randomized controlled trials (RCTs) were searched from seven online databases (PubMed, Cochrane Library, EMBASE, China National Knowledge Infrastructure, Oriental Medicine Advanced Searching Integrated System, Korean studies Information Service System, Research Information Sharing Service. The selected RCTs were evaluated for methodological quality through the Cochrane RoB. Results A total of 126 articles were identified, and 4 randomized controlled trials were selected for systematic review. In one study, it was found that there were statistically significant improvements in the Health-Related Quality of Life (FACTH&N total score, p<0.001). Additionally, significant effects were observed in measurements that represented the size of the quadriceps muscle (cross-sectional area of Vastus lateralis and Rectus femoris, p=0.004), maximum muscle strength, the twitch response of resistance muscles, and voluntary activation (p<0.001). However, no significant differences were observed between the intervention and control groups in terms of quadriceps muscle strength in two other studies (p>0.05). Lastly, while one study showed no significant differences in muscle fiber characteristics between the two groups, it did report significant improvements in measurements related to mitochondria within muscle tissue and muscle strength in the intervention group (p<0.05). Conclusions Neuromuscular electrical stimulation can be a method used to improve muscle strength in muscle wasting of cancer patients, but it is difficult to see its effects as significant compared to other treatments.

Treatment Response Evaluation by Computed Tomography Pulmonary Vasculature Analysis in Patients With Chronic Thromboembolic Pulmonary Hypertension

  • Yu-Sen Huang;Zheng-Wei Chen;Wen-Jeng Lee;Cho-Kai Wu;Ping-Hung Kuo;Hsao-Hsun Hsu;Shu-Yu Tang;Cheng-Hsuan Tsai;Mao-Yuan Su;Chi-Lun Ko;Juey-Jen Hwang;Yen-Hung Lin;Yeun-Chung Chang
    • Korean Journal of Radiology
    • /
    • v.24 no.4
    • /
    • pp.349-361
    • /
    • 2023
  • Objective: To quantitatively assess the pulmonary vasculature using non-contrast computed tomography (CT) in patients with chronic thromboembolic pulmonary hypertension (CTEPH) pre- and post-treatment and correlate CT-based parameters with right heart catheterization (RHC) hemodynamic and clinical parameters. Materials and Methods: A total of 30 patients with CTEPH (mean age, 57.9 years; 53% female) who received multimodal treatment, including riociguat for ≥ 16 weeks with or without balloon pulmonary angioplasty and underwent both non-contrast CT for pulmonary vasculature analysis and RHC pre- and post-treatment were included. The radiographic analysis included subpleural perfusion parameters, including blood volume in small vessels with a cross-sectional area ≤ 5 mm2 (BV5) and total blood vessel volume (TBV) in the lungs. The RHC parameters included mean pulmonary artery pressure (mPAP), pulmonary vascular resistance (PVR), and cardiac index (CI). Clinical parameters included the World Health Organization (WHO) functional class and 6-minute walking distance (6MWD). Results: The number, area, and density of the subpleural small vessels increased after treatment by 35.7% (P < 0.001), 13.3% (P = 0.028), and 39.3% (P < 0.001), respectively. The blood volume shifted from larger to smaller vessels, as indicated by an 11.3% increase in the BV5/TBV ratio (P = 0.042). The BV5/TBV ratio was negatively correlated with PVR (r = -0.26; P = 0.035) and positively correlated with CI (r = 0.33; P = 0.009). The percent change across treatment in the BV5/TBV ratio correlated with the percent change in mPAP (r = -0.56; P = 0.001), PVR (r = -0.64; P < 0.001), and CI (r = 0.28; P = 0.049). Furthermore, the BV5/TBV ratio was inversely associated with the WHO functional classes I-IV (P = 0.004) and positively associated with 6MWD (P = 0.013). Conclusion: Non-contrast CT measures could quantitatively assess changes in the pulmonary vasculature in response to treatment and were correlated with hemodynamic and clinical parameters.

Effect of Ischemic Preconditioning for Preventing Ischemic Injury of the Spinal Cord (척추 신경의 허혈성 손상 예방을 위한 허혈성 전처치의 효과)

  • 홍종면;차성일;송우익;홍장수;임승운;임승운;임승평
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.823-830
    • /
    • 2001
  • Background: Paraplegia is a serious complication of thoracic or thoracoabdominal aortic operations, which is related to ischemic injury of the spinal cord induced by low perfusion pressure during cross clamping of the aorta. Ischemic preconditioning of heart or brain with reversible sublethal ischemic injury induces resistance to subsequent lethal ischemia. The aim of this study is to investigate whether ischemic tolerance could be induced by the preconditioning of the spinal cord using swine model. Material and Method: The animals were randomly assigned to three groups: sham group(n=3), control group(n=6) and pre-conditioning group(n=8). In the sham group, we performed the left thoracotomy only without any ischemic injury. In the preconditioning group, the swine received reversible spinal cord ischemic injury by aortic clamping for 20 minutes, whereas control group had no previous aortic cross- clamping. Forty-eight hours later, the aorta was clamped for 30 minutes in both groups. Neurological examination was done 24 hours later, then the animals were euthanized for histopathology and malonedialdehyde(MDA) spectrophotometry assay of the spinal cord. Result: Statistically significant difference in neurological outcome was observed between the control and preconditioning groups at 24 hours after ischemic injury. The incidence of paraplegia and severe paresis was 100% in the control group, and 62.5% in the preconditing group(p=0.028). There was no statistically significant difference in histopathology and MDA assay of the ischemic spinal cord between these two groups with borderline statistical difference in MDA assay(p=0.0745). Conclusion: In the present swine study, ischemic preconditioning could induce tolerance against 30 minute ischemic insult of the spinal cord, although the animals did not completely recover(stand-up or walk). We expect that combining this preconditioning with other currently existing protection methods might lead to a synergistic effect, which warrants further investigation.

  • PDF

Quantitative Real-Time PCR of Porcine Parvovirus as a Model Virus for Cleaning Validation of Chromatography during Manufacture of Plasma Derivatives (혈장분획제제 제조공정에서 크로마토그래피 세척 검증을 위한 모델바이러스로서의 Porcine Parvovirus 정량)

  • Kil Tae Gun;Kim Won Jung;Lee Dong Hyuk;Kang Yong;Sung Hark Mo;Yoo Si Hyung;Park Sue-Nie;Kim In Seop
    • Korean Journal of Microbiology
    • /
    • v.41 no.3
    • /
    • pp.216-224
    • /
    • 2005
  • Chromatography has now been used successfully to provide the requisite purity for human plasma-derived biop-harmaceuticals such as coagulation factors and immunoglobulins. Recently, increasing attention has been focused on establishing efficient cleaning procedures to prevent potential contamination by microorganisms as well as carry-over contamination from batch to batch. The purpose of present study was to develop a cleaning validation system for the assurance of virus removal and/or inactivation during chromatography process. In order to establish an assay system for the validation of virus clearance during chromatography cleaning process, a quantitative real-time PCR method for porcine parvovirus(PPV) was developed, since PPV, a model virus for human parvovirus B19, has a high resistance to a range of physico-chemical treatment. Specific primers for amplification of PPV DNA was selected, and PPV DNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be 1.5 $TCID_{50}/ml$. The established real-time PCR assay was successfully applied to the validation of PPV removal and cleaning during SP-Sepharose cation chromatography for thrombin purification and Q-Sepharose anion chromatography for factor VIII purification. The comparative results obtained by real-time PCR assay and infectivity titrations suggested that the real-time PCR assay could be a useful method for chromatography cleaning validation and that it could have an additive effect on the interpretation and evaluation of virus clearance during the virus removal process.

Direct Bonding of Si(100)/NiSi/Si(100) Wafer Pairs Using Nickel Silicides with Silicidation Temperature (열처리 온도에 따른 니켈실리사이드 실리콘 기판쌍의 직접접합)

  • Song, O-Seong;An, Yeong-Suk;Lee, Yeong-Min;Yang, Cheol-Ung
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.556-561
    • /
    • 2001
  • We prepared a new a SOS(silicon-on-silicide) wafer pair which is consisted of Si(100)/1000$\AA$-NiSi Si (100) layers. SOS can be employed in MEMS(micro- electronic-mechanical system) application due to low resistance of the NiSi layer. A thermally evaporated $1000\AA$-thick Ni/Si wafer and a clean Si wafer were pre-mated in the class 100 clean room, then annealed at $300~900^{\circ}C$ for 15hrs to induce silicidation reaction. SOS wafer pairs were investigated by a IR camera to measure bonded area and probed by a SEM(scanning electron microscope) and TEM(transmission electron microscope) to observe cross-sectional view of Si/NiSi. IR camera observation showed that the annealed SOS wafer pairs have over 52% bonded area in all temperature region except silicidation phase transition temperature. By probing cross-sectional view with SEM of magnification of 30,000, we found that $1000\AA$-thick uniform NiSi layer was formed at the center area of bonded wafers without void defects. However we observed debonded area at the edge area of wafers. Through TEM observation, we found that $10-20\AA$ thick amourphous layer formed between Si surface and NiSix near the counter part of SOS. This layer may be an oxide layer and lead to degradation of bonding. At the edge area of wafers, that amorphous layer was formed even to thickness of $1500\AA$ during annealing. Therefore, to increase bonding area of Si NiSi ∥ Si wafer pairs, we may lessen the amorphous layers.

  • PDF

Relation between ERCC1 Expression in Sputum and Survival after Cisplatin-Based Chemotherapy in Patients with Non-Small Cell Lung Cancer (비소세포 폐암환자의 객담 내 ERCC1 발현정도와 cisplatin 복합화학요법 후 치료반응)

  • Yang, Sung Woo;Choi, Pyoung Rak;You, Hong Jun;Kim, Jin Gu;Oak, Chul Ho;Jang, Tae Won;Jung, Maan Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.2
    • /
    • pp.151-159
    • /
    • 2006
  • Background : Excision repair cross complementing gene 1 (ERCC1) not only has a protective role against carcinogens, but plays an important role in cisplatin-resistance via the repair of cisplatin-DNA adducts. This study investigated the association between the ERCC1 expression levels in sputum and survival after cisplatin-based chemotherapy in patients with inoperable non-small cell lung cancer (NSCLC). Methods : Using the sputum collected from 67 inoperable (stage IIIa-IV) NSCLC patients treated with either taxanes (33 cases) or gemcitabine (34 cases) plus cisplatin, the relative expression levels of ERCC1 and the expression of the tumor specific antigen, MAGE, were examined by the quantitative RT-PCR and RT-PCR, respectively. The response and survival were compared with the relative level of ERCC1 or MAGE expression and the treatment modality. Results : In the sputum, ERCC1 and MAGE was detected in 74.6% and 40.2% of patients, respectively. Using the median ERCC1 level, the patients were classified as having high or low ERCC1 expression. The median overall survival (MST) was significantly longer in patients with a high ERCC1 expression level than those with a low expression level (84 weeks vs. 44 weeks respectively, P=0.017). In the taxene-based treatment group, the MST was longer than the gemcitabine group (79 weeks vs. 47 weeks, respectively, P=0.03). The levels of ERCC1 were significantly higher in patients who were MAGE-positive (P=0.003). In the MAGE-negative patients, the MST was longer in the high ERCC1 group (103 weeks vs. 43 weeks, P=0.008), but not in the MAGE-positive patients (62 weeks vs. 44 weeks, P=0.348). Conclusion : ERCC1 expression in the sputum can be a prognostic factor for survival after chemotherapy in patients with inoperable NSCLC.