• Title/Summary/Keyword: cross-flow ultrafiltration

Search Result 33, Processing Time 0.023 seconds

Effects of ring number and baffled-ring distances on ultrafiltration in the tubular membrane inserted concentrically with a ring rod

  • Yeh, Ho-Ming;Ho, Chii-Dong;Li, Cha-Hsin
    • Membrane and Water Treatment
    • /
    • v.3 no.1
    • /
    • pp.51-62
    • /
    • 2012
  • The permeate flux declination along an ultrafilter membrane is due mainly to the concentration-polarization resistance increment and the decline in transmembrane pressure. It was found in previous works that the concentration polarization resistance could be reduced in a ring-rod tubular membrane ultrafilter using the turbulent behavior. In the present study, the performance was further improved by properly and gradually decreasing the baffled-ring distance along the cross-flow channel coupled with properly adjusting the number of baffled rings. This theoretical analysis is based on the mass and momentum balances as well as the application of the resistance-in-series model. The correlation predictions are confirmed with the experimental results for dextran T500 aqueous solution ultrafiltration.

Effects of Natural Convection Instability on Membrane Performance in Dead-end and Cross-flow Ultrafiltration

  • Youm, Kyung-Ho;Anthony G. Fane
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.04a
    • /
    • pp.6-10
    • /
    • 1995
  • An inevitable problem feature of membrane processing is concentration polarization (CF) which is a result of the accumulation of retained solutes at the membrane surface. In ultrafiltration (UF), this accumulation can lead to fouling due to the irreversible deposition of macromolecules both at the membrane surface and in the membrane pores. To reduce or control CP and folding, many possible methods have been considered [1]. One of the most effective approaches is to induce fluid instability near the membrane surface by using pusation flow [2, 3], Taylor [4] and Dean [5, 6] vortex flows. Winzeler and Belfort [6] have comprehensively reviewed several possible attempts to use fluid instabihties for improved membrane performance.

  • PDF

Application of a Pulse Electric Field to Cross-flow Ultrafiltration of Protein Solution

  • Kim, Hyong-Ryul;Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.4 no.1
    • /
    • pp.46-50
    • /
    • 1999
  • The application of pulsed electric field was investigated in the crossflow ultrafiltration of BSA (bovine serum albumn) to economize the application time of electric current as well as to avoid inherent problems of long-term application of electric field. During the application of various cyclic patterns of pulsed electric current, the averaged filtration flowrate and the degree of concentration were maintained higher than those obtained in the absence of electric current application. The temperature increase, pH change, and BSA loss by electrodeposition were all negligible during the operation. The averaged filtration flowrate increased as the ON/OFF duration ratio of electric current was higher and as the period of ON/OFF cycle was shorter. The re-establishment of concentration polarization was dependent to the duration of current OFF state and, therefore, a longer duration of OFF state was not favorable in maintaining higher filtration flow rate. Although the averaged filtration flowrate was enhanced as the magnitude of electric current increased, the flowrate enhancement became smaller as the magnitude of current value above which the degree of electrokinetic depolarization is no further improved.

  • PDF

Effect of Ozonation on Cross-flow Filtration of Polysulfone Ultrafiltration Membrane (폴리설펀 한외여과막공정에서 오존의 영향)

  • 박영규
    • Membrane Journal
    • /
    • v.11 no.4
    • /
    • pp.179-189
    • /
    • 2001
  • Effect of ozonation on permeate flux was studied by using polysulfone ultrafiltration membrane. The filtration was first carried out by permeating phenol solutions under 3$kg_{f}$/$cm^2$ until steady-state flux was obtained. Then, the ozone of concentration range between 10 and 45 mg/1.min was ozonated in water for reducing the fouling on the UF membrane. Treatment of chemical wastewater by combined ozone and membrane filtration methods was also investigated for the final purpose. The Fenton method assisted by chemical coagulation was employed as a prtreatment method and found to be highly efficient in removing a large amount of organic compounds. And it was found that the ozonation made the permeate flux enhance in the phenol solution and phenolic-chemical wastewaster by 10% and oxidation by ozone and hydrogen peroxide was more effective. Evidence was presented that TMP decreased in more ozone concentrated water and it was found that the ozone-mediated membrane would have a limited role to prevent the membrane fouling rather than to eliminate fully.

  • PDF

FLUX DECLINE DURING THE ULTRA-FILTRATION OF DILUTE SI COLLOIDAL SOLUTION WITH HOLLOW FIBER MEMBRANE

  • Park, Ho-Sang;Nam, Suk-Tae;Jeon, Jae-Hong;Lee, Seok-Ki
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.95-96
    • /
    • 1999
  • The ultrafiltration behavior of dilute colloidal solution containing Si particles has been investigated. The experiments in cross flow mode have been performed at different operating condition by using the membrane with 20 kDa cut-off. The flux decline was due to the development of membrane fouling which was a dynamic process of two distinctive stages. For the high trans-membrane pressure, the pore blocking resistance was dominant at the initial period of filtraion and was followed by the cake resistance. And for the low cross flow velocity, the membrane fouling was governed by the cake filtration model at the initial stage of filtration process. Flux jump was observed temporally during the membrane filtration of mixed feed solution.

  • PDF

Preparation and characterization of PVDF/TiO2 composite ultrafiltration membranes using mixed solvents

  • Tavakolmoghadam, Maryam;Mohammadi, Toraj;Hemmati, Mahmood
    • Membrane and Water Treatment
    • /
    • v.7 no.5
    • /
    • pp.377-401
    • /
    • 2016
  • To study the effect of titanium dioxide ($TiO_2$) nanoparticles on membrane performance and structure and to explore possible improvement of using mixed solvents in the casting solution, composite polyvinylidene fluoride (PVDF) ultrafiltration membranes were prepared via immersion precipitation method using a mixture of two solvents triethyl phosphate (TEP) and dimethylacetamide (DMAc) and addition of $TiO_2$ nanoparticles. Properties of the neat and composite membranes were characterized using scanning electron microscope (SEM), energy dispersive X-ray spectroscopy (EDS), Atomic force microscopy (AFM) and contact angle and membrane porosity measurements. The neat and composite membranes were further investigated in terms of BSA rejection and flux decline in cross flow filtration experiments. Following hydrophilicity improvement of the PVDF membrane by addition of 0.25 wt.% $TiO_2$, (from $70.53^{\circ}$ to $60.5^{\circ}$) degree of flux decline due to irreversible fouling resistance of the composite membrane reduced significantly and the flux recovery ratio (FRR) of 96.85% was obtained. The results showed that using mixed solvents (DMAc/TEP) with lower content of $TiO_2$ nanoparticles (0.25 wt.%) affected the sedimentation rate of nanoparticles and consequently the distribution of nanoparticles in the casting solution and membrane formation which influenced the properties of the ultimate composite membranes.

Ultrafiltration Characteristics of Poly(vinyl Alcohol) Solution and Theoretical Investigations (Poly(vinyl Alcohol) 용액의 한외여과 특성과 이론적 고찰)

  • 이상화;이영철
    • Membrane Journal
    • /
    • v.6 no.4
    • /
    • pp.203-212
    • /
    • 1996
  • The operating parameters influencing on limiting flux was investigated in the ultrafiltration of PVA, and a new model, which is based on the Amiar model using the concept of heat transfer coefficient, was devised to overcome the limitation of gel-layer model. Using polysulfone plate-unit membrane (MWCO=20,000) and hollow-fiber membrane (MWCO= 30,000), ultrafiltration characteristics of PVA was examined with the variation of operating parameters such as cross flow velocity, transmembrane pressure, temperature, and PVA concentration. According to experimental results, the ultrafiltration of PVA through polysulfone membrane is mainly controlled by well-known phenomena of concentration polarization caused by gel-layer formation. On the contrary, in hollow fiber membrane was observed upward limiting flux which can not be explained by gel-layer model. New model was applied to predict the upward limiting flux behavior with partial satisfaction. The application of new model including viscosity correction factor, however, revealed that PVA ultrafiltration is closely related to the viscosity of permeating fluid.

  • PDF

Treatment of oily wastewater from cold-rolling mill through coagulation and integrated membrane processes

  • Cheng, Xue-Ni;Gong, Yan-Wen
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.159-163
    • /
    • 2018
  • The feasibility of applying coagulation-integrated microfiltration (MF) as a pretreatment for an ultrafiltration (UF) feed in oily wastewater treatment was investigated. The effects of different coagulants on oil removal rates from wastewater were studied. The maximum oil removal rate of 82% was obtained after coagulation with 130 mg/L of polyaluminium chloride (PAC). UF flux reached $95L/(m^2{\cdot}h)$ with coagulation-integrated MF as pretreatment. This value was 2.5 times higher than that flux obtained without pretreatment. The value of UF flux increased as the transmembrane pressure (TMP) and cross-flow velocity (CFV) of the UF module increased. UF flux gradually increased when TMP and CFV exceeded 0.4 MPa and 3 m/s, respectively, because of concentration polarization and membrane fouling stabilization. Chemical oxygen demand reduction and oil removal rate reached 95.2% and 98.5%, respectively, during integrated membrane processing with a PAC concentration of 130 mg/L, TMP of 0.4 MPa, and CFV of 3 m/s for UF. In addition, sequentially cleaning the fouling membrane with NaOH and $HNO_3$ aqueous solutions caused UF flux to recover to 90%. These encouraging results suggested that the hybrid integrated membrane process-based coagulation and MF + UF are effective approaches for oily wastewater treatment.

A Study on the Concentration Polarization Layer Resistance in Ultrafiltration of Macromolecular Solutions (고분자 용액의 한외여과에서 농도분극층 저항에 관한 연구)

  • 염경호
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.59-66
    • /
    • 1992
  • The experimental studies were carried out on ultrafiltration of PEG #6000 and dextran 70T macromole¬cules. using an asymmetric cellulose acetate membrane in a cross flow plane type cell. Effects of pressure difference. feed concentration were studied on permeate flux and observed rejection for both the macromole¬cules. and the concentration polarization layer resistance $R_{b1}$ on permeate flux was analysed. The concentration polarization layer resistance $R_{b1}$ was correlated with the average macromolecule concen¬tration $C_{b1}$ in polarization layer. The resulting dimensionless correlation was expressed as : $\frac{R_{b1}}{{R_m}}=\alpha[\frac{\rho_{b1}}{C_{b1}}]^\beta$

  • PDF

Analysis of EDCs by Mass Spectrometry and their Removal by Membrane Filtrations (질량분석법에 의한 내분비계 장애물질의 분석과 막 여과에 의한 제거)

  • Kim Tae-Uk;Yeon Kyeong-Ho;Cho Jaeweon;Moon Seung-Hyeon
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.297-309
    • /
    • 2005
  • As a number of potential endocrine disrupting compounds (EDCs) are released into the environment, recently growing attention has been drawn to them. Therefore sensitive and reliable analytical methods are essential to monitor those compounds. In this study, complementary CC-MS and LC-MS were employed to analyze the endocrine disrupters, and the results of two methods were compared for di(2-ethylhexyl)phthalate (DEHP), benzylbutylphthalate (BBP), pentachlorophenol (PCP), and 4,4'-Isopropylidenediphenol (Bisphenol-A, or BPA). The results indicate that it was possible to lower the detection limits of EDCs by LC-MS. Also, LC-MS enabled to identify the EDCs as almost intact molecules. Furthermore, this study presented a nanofiltration membrane (MWCO 250) and a ultrafiltration membrane (MWCO 1,000) filtration system as methods far removing EDCs from drinking water containing $\gamma$-BHC, p,p'-DDE, BBP, p,p'-DDT, DEHP, PCP, and BPA. Cross-flow type nanofiltrations showed $100\%$ removal of EDCs, and the result implies that MWCO 250 nanofilter was sufficient for treatment of EDCs. The ratio of permeate flux to mass transfer coefficient of nanofiltration, high flux ultrafiltration, and low flux ultrafiltration with ultrapure water were 0.67, 3.4, and 0.44, respectively. It was found that nanofiltration and low flux ultrafiltration were operated at a diffusion dominant condition, and the high flux ultrafiltration was operated at a convection dominant condition. Furthermore, a diffusion dominant process attained reasonable rejection of EDCs. The removal in the ultrafiltration was depending on the molecular weight of an EDC, and the filtration was governed by diffusion-dominant hydrodynamic conditions.