• Title/Summary/Keyword: cross magnetic saturation

Search Result 21, Processing Time 0.023 seconds

Analytical Study Considering Both Core Loss Resistance and Magnetic Cross Saturation of Interior Permanent Magnet Synchronous Motors

  • Kim, Young-Kyoun
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.280-284
    • /
    • 2012
  • This paper presents a method for evaluating interior permanent magnet synchronous motor (IPMSM) performance over the entire operation region. Using a d-q axis equivalent circuit model consisting of motor parameters such as the permanent magnetic flux, copper resistance, core loss resistance, and d-q axis inductance, a conventional mathematical model of an IPMSM has been developed. It is well understood that in IPMSMs, magnetic operating conditions cause cross saturation and that the iron loss resistance - upon which core losses depend - changes according to the motor speed; for the sake of convenience, however, d-q axis machine models usually neglect the influence of magnetic cross saturation and assume that the iron loss resistance is constant. This paper proposes an analysis method based on considering a magnetic cross saturation and estimating a core loss resistance that changes with the operating conditions and speed. The proposed method is then verified by means of a comparison between the computed and the experimental results.

Standstill Identification of Magnetic Flux Saturation Model Including Cross-Saturation for Synchronous Motors (상호 포화를 포함한 자기저항 동기 전동기의 자속 포화 모델에 대한 정지 상태 추정 기법)

  • Woo, Tae-gyeom;Park, Sang-woo;Choi, Seung-Cheol;Yoon, Young-Doo;Lee, Hak-Jun;Hong, Chanook;Lee, Jeongjoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.364-371
    • /
    • 2021
  • A magnetic flux saturation model of Synchronous Reluctance Motors (SynRMs) and a parameter estimation method are proposed at standstill. The proposed magnetic flux model includes the nonlinear relationship between the current and the magnetic flux for self-saturation and cross-saturation. Voltage is injected at standstill to estimate the magnetic flux saturation model. Voltages are injected into the d-axis and q-axis to obtain data on self-saturation. Subsequently, voltages are simultaneously injected into the d-q axis to obtain data on cross-saturation. On the basis of the measured current and the calculated magnetic flux, the parameters of the proposed model are estimated using the least square method (LSM). Simulation and experiment were performed on a 1.5-kW SynRM to verify the proposed method. The proposed model can be used to create a high-efficiency operation table, a sensorless algorithm, and a current controller to improve the control performance of a motor.

Modeling of a Dual Stator Induction Generator with and Without Cross Magnetic Saturation

  • Slimene, Marwa Ben;Khlifi, Mohamed Arbi;Fredj, Mouldi Ben;Rehaoulia, Habib
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.284-289
    • /
    • 2015
  • This paper discusses general methods of modelling magnetic saturation in steady-state, two-axis (d & q) frame models of dual stator induction generators (DSIG). In particular, the important role of the magnetic coupling between the d-q axes (cross-magnetizing phenomenon) is demonstrated, with and without cross-saturation. For that purpose, two distinct models of DSIGs, with and without cross-saturation, are specified. These two models are verified by an application that is sensitive to the presence of cross-saturation, to prove the validity of these final methods and the equivalence between all developed models. Advantages of some of the models over the existing ones and their applicability are discussed. In addition, an alternative is given to evaluate all saturation factors (static and dynamic) by just calculating the static magnetizing inductance which is simply the magnitude of the ratio of the magnetizing flux to the current. The comparison between the simulation results of the proposed model with experimental results gives a good correspondence, especially at startup.

D-Q Flux Linkage Identification for Interior Buried Permanent Magnet Synchronous Motor considering Cross-Magnetization (교차자화작용을 고려한 매입형 영구자석 동기전동기의 통합형 d-p축 쇄교자속 추출)

  • Kim, Min-Seok;Kwak, Sang-Yeop;Jung, Hyun-Kyo;Jung, Sang-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2116-2121
    • /
    • 2007
  • Numerical identification of synthetic d-q flux linkage, representative parameters for analyzing interior buried PM synchronous Motor(IPMSM) with distinguished magnetic saturation, has been peformed. Particularly, numerical identification of synthetic flux linkage using modified Finite Element Method(F.E.M) has been taken cross-magnetization of multi-layered PM configuration into consideration. Futhermore, experimental identification on the purpose-built prototype has been made to verify the validity of the numerically identified synthetic d-q flux linkages.

Complete Relaxation and Conformational Exchange Matrix (CORCEMA) Analysis of Saturation Transfer Difference (STD) NMR Spectra of Ligand-Protein Complexes

  • Krishna, N.Rama;Jayalakshmi, V.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.2
    • /
    • pp.94-102
    • /
    • 2002
  • An interesting recent application of intermolecular NOE experiment is the saturation transfer difference NMR(STD-NMR) method that is useful in screening compound libraries to identify bio-active ligands. This technique also identifies the group epitopes of the bound ligand in a reversibly forming protein-ligand complex. We present here a complete relaxation and conformational exchange matrix (CORCEMA) theory (Moseley et al., J. Magn. Reson. B, 108, 243-261 (1995)) applicable for the STD-NMR experiment. Using some ideal model systems we have analyzed the factors that influence the STD intensity changes in the ligand proton NMR spectrum when the resonances from some protons on the receptor protein are saturated. These factors will be discussed and some examples of its application in some model systems will be presented. This CORCEMA theory for STD-NMR and the associated algorithm are useful in a quantitative interpretation of the STD-NMR effects, and are likely to be useful in structure-based drug design efforts. They are also useful in a quantitative characterization of protein-protein (or protein-nucleic acid) contact surfaces from an intermolecular cross-saturation NMR experiment.

  • PDF

Maximum Power Control of IPMSM Considering Nonlinear Cross-Magnetization Effects

  • Kim, Youn-Hyun;Kim, Won-Kyu;Kim, Sol
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.940-947
    • /
    • 2012
  • Interior permanent magnet synchronous motor is widening its application compared to other AC machines because of magnetic and reluctance torque. Despite of the advantages, improving control performance with parameter nonlinearity consideration is crucial during the field weakening control. This paper shows a maximum power control method at the field weakening region that considers d, q inductance's nonlinearity due to magnetic saturation and d, q mutual inductance. To verify the feasibility of control scheme, FEM simulations and experiments about comparison between linear and nonlinear maximum power control are carried out.

The Effect of Pinholes on Magnetic Behaviour of Antiferromagnetically Coupled Ni-Fe/Cu Mulitlayers

  • Stobiecki, F;Lucinski, T;Dubowik, J;Szymanski, B;Urbaniak, M;Castano, F.J;Stobiecki, T
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.89-91
    • /
    • 1998
  • The magnetisation behaviour of polycrystalline permalloy/copper multilayers with mixed antiferromagnetic/ferromagnetic coupling was investigated as function of temperature. The results are discussed in a framework of a realistic model of anitferromagnetically coupled layers connected by ferromagnetic pinholes. A microstructure of pinholes (their density and dimensions) was varied either by a proper annealing treatment or by choosing samples with various Cu spacer thicknesses. It was demonstrated that the temperature changes of the net magnetic moment measured in a magnetic field smaller than the saturation field was strongly affected by the composition of the pinholes, their density, cross-sectional area and their lengths.

  • PDF

Quantitative Approach to the Magnetic Force of a Cylindrical Permanent Magnet Acting on a Ferromagnetic Object (원형 막대자석이 강자성 물체에 작용하는 자기력에 대한 정량적 접근)

  • Hyun, Donggeul;Shin, Aekyung
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1249-1261
    • /
    • 2018
  • The quantitative representation for the magnetic force of a cylindrical permanent magnet acting on a ferromagnetic cylindrical object was derived on the basis of magnetization theories, and the Gilbert and Ampere models of magnetism. The magnetic force derived in this study is directly proportional to the remanent magnetization magnetic field, the cross-sectional area of the permanent magnet, the saturation magnetic field, and the cross-sectional area of the ferromagnetic object and is inversely proportional to the square of the quantity related to the distance between the permanent magnet and the ferromagnetic object. The magnetic forces of an AlNiCoV cylindrical permanent magnet and a Ferrite cylindrical permanent magnet, both with a radius of 0.4 cm and a length of 7 cm, acting on ferromagnetic objects at distances farther than the radius were calculated to be less than 3.6711 N and 0.1857 N, respectively.

Development of Characteristics Analysis Program (FEMCAD) for IPMSMs (매입형 영구자석 동기전동기 (IPMSMs) 특성해석 프로그램 (FEMCAD) 개발)

  • Kim, Young-Kyoun;Rhyu, Se-Hyun;Jung, In-Soung;Hur, Jin;Sung, Ha-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1035-1036
    • /
    • 2007
  • This paper presents the characteristics analysis of Interior Permanent Magnet Synchronous Motors(IPMSMs). The development of this program is based on Matlab. In oder to achieve the development of the program, basis algorithm for IPMSMs analysis took advantage of equivalent magnetic circuit analysis technique. The equivalent magnetic circuit analysis for IPMSMs are based on a rotate synchronous d-q reference frame. The mathematical model of the d-q frame voltage equations is used frequently for the analysis of IPMSMs. This program can consider a cross saturation effect and a iron loss and mechanical loss, and provide fast analysis results of IPMSMs characteristics.

  • PDF