Abstract
Numerical identification of synthetic d-q flux linkage, representative parameters for analyzing interior buried PM synchronous Motor(IPMSM) with distinguished magnetic saturation, has been peformed. Particularly, numerical identification of synthetic flux linkage using modified Finite Element Method(F.E.M) has been taken cross-magnetization of multi-layered PM configuration into consideration. Futhermore, experimental identification on the purpose-built prototype has been made to verify the validity of the numerically identified synthetic d-q flux linkages.
Keywords
Cross-magnetization; Interior Permanent Magnet Synchronous Motor; Finite Element Method; Magnetic saturation; field weakening control;
Citations & Related Records

Times Cited By SCOPUS : 0
연도 인용수 순위
  • Reference
1 Wen L. Soong, Mesimi Ertugrul, 'Field-Weakening Performance of Interior Permanent-Magnet Motors', IEEE Trans. on 1A, Vol. 38, No.5, September 2002
2 T. J. E. Miller, J. R. Hendershot Jr., Brushless Permanent Magnet and Reluctance Motor Drives, Oxford, 1989
3 N. Bianci, S. Bolognani, 'Interior PM Synchronous Motor for High Performance Applications,' PCC_Osaka 2002, Proceedings of the, Vol. 1, pp. 148-153, 2002
4 Stumberger B, Stumberger G, Dolinar D, Hamler A Trlep M, 'Evaluation of saturation and cross-magnetization effects in interior permanent-magnet synchronous motor' IEEE Transactions on Industry Applications, vol. 39, issue 5, pp.1264-1271, September. 2003   DOI   ScienceOn
5 Hu Jianhui; Zou Jibin; Liang Weiyan, 'Finite element calculation of the saturation DQ-axes inductance for a direct drive PM synchronous motor considering cross-magnetization,' Proc. Of PEDS '03, Vol. 1, No. 17-20, pp. 677-681, NOv. 2003
6 Erderlyi, E. A and Fuchs. E. F, 'Nonlinear magnetic field analysis of DC Machine,' IEEE. On power Apparatus and System, Vol. PAS-89, pp.1546-1583, 1970   DOI   ScienceOn
7 Lovelace.E.C., Keim.T., Lang.J.H, Wentzloff.D.D., Jahns.T.M., Wai.J., McCleer.P.J., 'Design and experimental verification of a direct-drive interior PM synchronous machine using a saturable lumped-parameter model,' Proc. of 37th IAS Annual Meeting, Vol. 4, pp.2486-2492, Oct. 2002
8 S. Y. Kwak, J. K. Kim and H. K. Jung, 'Characteristic analysis of multi layer-buried magnet synchronous motor using fixed permeability method', IEEE Trans. on Energy Conversion, vol. 20, pp. 549-555, Sept. 2005   DOI   ScienceOn
9 C. Mademlis, V. G. Agelidis, 'A High-Performance Vector Controlled Interior PM Synchronous Motor Drive with Extended Speed Range Capability,' IECON '01, Vol. 2, pp. 1475-1482, 2001
10 N. Bianci and S. Bolognani, 'Magnetic models of saturated interior permanent magnet motors based on finite element analysis,' Proc. of IAS Annual Meeting, pp.27-34, 1998
11 E. Levi, 'Saturation modeling in dq axis models of salient pole synchronous machines,' IEEE Trans. on Energy Conversion, vol. 14, pp.4450, Mar. 1999
12 Rahman K. M, Hiti S, 'Identification of machine parameters of a synchronous motor', IEEE Trans. on Industry Applications, vol. 41, issue 2, pp. 557-565, Mar- Apr. 2005   DOI   ScienceOn