• Title/Summary/Keyword: cross flow

Search Result 2,033, Processing Time 0.032 seconds

Experimental Study on Seepage Losses in Earth Channel (흙 수로에 대한 삼수손실량 추정에 관한 실험적 연구)

  • 정하우;유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.1
    • /
    • pp.2853-2877
    • /
    • 1973
  • Models of cross-sections and channels were made in order to measure seepage losses. Cross-sections were made of sand, sandy clay loam and loam, their thicknesses being 30cm and 40cm, respectively. Flow depths kept in the cross-sections were 4cm, 6cm, 8cm and 10cm. Straight and curved channel models were provided so as to measure seepage losses, when constant water depths maintained at the heads of the channels were 7.3cm and 5.7cm, respectively. The results obtained in this experiment are presented as follows: 1) A cumulative seepage loss per unit length at a point in the channel varies in accordance with time and flow depth. The general equation of cumulative seepage loss may be as follows(Ref. to Table V.25): $$q_{cum}=\int_{o}^aq(a)dt+\int_a^bq(b)dt+\int_b^tq(c)dt$$ 2) In case that the variation of water depth through the channel is slight, the total seepage loss may be computed by applying the following general equation: $$\={q}_{cum}{\cdot}x=\int_o^tq_{cum}\frac{{\partial}x}{{\partial}t}dt$$ 3) Because seepage loss varies considerably according to water depth in case that the variation of flow depth through the channel is great, seepage loss should be computed by taking account of the change of flow depth. 4) The relation between time and traveling distance of water flow may be presented as the following general equation(Ref. to Table V.29): $$x=pt^r$$ 5) The ratios of the seepage losses of the straight channel to the curved channel are 1:1.03 for a flow depth of 7.3cm and 1:1.068 for that of 5.7cm. 6) The ratios of the seepage losses occurring through the bottom to those through the inclined plane in the channel cross-section are 1:2.24 for a water depth of 8cm and 1:2.47 for a depth of 10cm in case that soil-layer is 30cm in thickness. Similarly, those ratios are 1:2.62 and 1:2.93 in case of a soil-layer thickness of 40cm(Ref. to Table V.5).

  • PDF

New Method of Computing the Stokes Drift Including Shear Effect in the Cross-Sectional Flow Field (유수단면 흐름장에서 Shear 효과를 갖는 Stokes Drift의 계산법)

  • Kim, Jong-Hwa;Park, Byong-Su
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.1
    • /
    • pp.9-26
    • /
    • 1997
  • Stokes drift(SD) and Lagrangian discharge(LD) are important factors for analysis of flushing time, tidal exchange, solute transport and pollutant dispersion. The factors should be calculated using the approached method to flow phenomena. The aim of this paper re-examines the previous procedures for computing the SD and LD, and is to propose the new method approached to stratified flow field in the cross-section of coastal region, e.g. Masan Bay. The intensity of velocity near the bottom boundary layer(BBL) depends on the sea-bed irregularity in the coastal estuaries. So we calculated the depth mean velocity(DMV) considering that of BBL omitted in Kjerfve's calculation method. It revealed that BBL effect resulting in application of the bay acts largely on DMV in half more among 1l stations. The new expression of SD and LD per unit width in the cross-section using the developed DMV and proposed decomposition procedure of current were derived as follow : $$Q=u_0+\frac{1}{2}H_1{U_1cos(\varphi_h-\varphi_u)+U_3cos(\varphi_h-\varphi{ud})} LD ED SD$(Q_{skim}+Q_{sk2}) The third term, $Q_{sk2}$, on the right-hand of the equation is showed newly and arise from vertical oscillatory shear. According to the results applied in 3 cross-sections including 11 stations of the bay, the volume difference between proposed and previous SD was founded to be almost 2 times more at some stations. But their mean transport volumes over all stations are 18% less than the previous SD. Among two terms of SD, the flux of second term, $Q_{skim}$, is larger than third term, $Q_{sk2}$, in the main channel of cross-section, so that $Q_{skim}$ has a strong dependence on the tidal pumping, whereas third term is larger than second in the marginal channel. It means that $Q_{sk2}$ has trapping or shear effect more than tidal pumping phenomena. Maximum range of the fluctuation in LD is 40% as compared with the previous equations, but mean range of it is showed 11% at all stations, namely, small change. It mean that two components of SD interact as compensating flow. Therefore, the computation of SD and LD depend on decomposition procedure of velocity component in obtaining the volume transport of temporal and spacial flow through channels. The calculation of SD and LD proposed here can separate the shear effect from the previous SD component, so can be applied to non-uniform flow condition of cross-section, namely, baroclinic flow field.

  • PDF

A Large-scale Structural Mixing Model applied to Blowout of Turbulent Nonpremixed Jet Flames in a Cross air-flow

  • Lee, Kee-Man;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.163-173
    • /
    • 1997
  • This article presents an application of a large-scale structural mixing model (Broadwell et al. 1984) to the blowout of turbulent reacting jets discharging perpendicularly into an unconfined cross air-flow. In an analysis of a common stability curve, a plausible explanation can be made that the phenomenon of blowout is related only to the mixing time scale of the two flows. The most notable observation is that the blowout distance is traced at fixed positions at all times according to the velocity ratio R. Measurements of the lower blowout limits in the liftable flame agree qualitatively with the blowout parameter ${\varepsilon}$, proposed by Broadwell et al. Good agreement between the results calculated by a modified blowout parameter ${\varepsilon}^'$ and experimental results confirms the important effect of a large-scale structure in specifying the stabilization feature of blowouts.

  • PDF

Numerical Study of the blade dynamics for a cross-flow turbine

  • Sato Yuko;Kawamura Tetuya
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.230-231
    • /
    • 2003
  • Two and three-dimensional flows around a cross-flow wind turbine are investigated by the numerical simulation. The turbine studied in this paper has cylindrical shape with many small blades along its periphery. Incompressible Navier-Stokes equation is used for this simulation. A rotating coordinate system, which rotates at the same speed of the turbine, is used in order to simplify the boundary conditions on the blades of the turbine. Additionally, a boundary fitted coordinate system is employed in order to express the shape of the blades precisely. A third order upwind scheme is chosen for the approximation of the non-linear terms. When the number of blades is about 10, the highest torque is obtained.

  • PDF

A Study on the Optimal Configuration and Performance Improvement of a Micro Cross-Flow Hydraulic Turbine (마이크로 관류수차의 최적형상 및 성능향상에 관한 연구)

  • Zhao, Linhu;Lee, Young-Ho;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.296-303
    • /
    • 2006
  • Recently, micro hydropower attracts attention because of its clean. renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of micro hydropower and it is necessary to study for the effective turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the micro hydropower turbine. Therefore a cross-flow turbine is proposed for micro-hydropower in this study because of its simple structure and high possibility of applying to low head. The purpose of this study Is to further optimize the turbine structure and improve the performance. A guide vane is removed and the runner chamber is made compact using a new air supply method. The results show that the efficiency of the turbine is improved in a wide operating range and the size of the turbine is remarkably reduced.

Simplification of Turbine Structure and Performance Improvement of Micro Cross-Flow Hydropower Turbine (마이크로 관류수차의 구조 간소화 및 성능향상)

  • Kurokawa, Junichi;Choi, Young-Do;Zhao, Linhu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.819-824
    • /
    • 2005
  • Recently, micro hydropower attracts attention because of its clean, renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of micro hydropower and it is necessary to study for the effective turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the micro hydropower turbine. Therefore, a cross-flow turbine is proposed for micro-hydropower in this study because of its simple structure and high possibility of applying to low head. The purpose of this study is to further simplify the turbine structure and improve the performance, A guide vane is removed and the runner chamber is made compact using a new air supply method. The results show that the efficiency of the turbine is improved in a wide operating range and the size of the turbine is remarkably reduced.

  • PDF

A Three-Dimensional Turbulence Model far the Thermal Discharge into Cross-Flow Field (가로흐름 수역으로 방출되는 3차원 온배수 난류모형)

  • 이남주;최흥식;허재영
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.2
    • /
    • pp.148-155
    • /
    • 1995
  • For an accurate prediction of the temperature Held induced by surface discharge of heated water into an ambient cross-flow field. a three-dimensional near-field numerical model using k-$\varepsilon$ turbulence clousure is developed Rather restricted as it is, the numerical results of the model agree well with the experimental data. The developed model simulates quite adequately the stratification, gravitational lateral spreading, and upward entrainment of thermal jet which cannot be simulated by a depth-integrated two-dimensional numerical model, as well as the interaction with cross-flow.

  • PDF

An experimental study on the performance of a window system air-conditioner using R407C and R410B (R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구)

  • Kim, M.H.;Shin, J.S.;Kim, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF

Prediction of Manoeuvrability of a Ship with Low Forward Speed in Shallow Water (천수 영역에서 저속 운항하는 선박의 조종성능 추정에 관한 연구)

  • Kim, Se-Won;Yeo, Dong-Jin;Rhee, Key-Pyo;Kim, Dong-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.3
    • /
    • pp.280-287
    • /
    • 2008
  • In this paper, a mathematical model for a ship manoeuvring with low forward speed in shallow water was suggested. Based on the cross flow model with low forward speed in deep sea, hull, propeller and rudder models were modified to consider the shallow water effects. Static drift and PMM tests were performed to obtain the cross flow drag coefficients and hydrodynamic coefficients. To validate suggested mathematical model, numerical simulation results were compared with those of sea-trials. Through comparisons, it was concluded that suggested mathematical model could give proper estimation on turning test results.

Application of MCC and Inverse Method for the AVHRR/SST (해수면 온도분포에 대한 최대상관계수법과 역행렬법의 적용)

  • 이태신;정종률
    • Korean Journal of Remote Sensing
    • /
    • v.11 no.1
    • /
    • pp.19-29
    • /
    • 1995
  • The surface velocities were estimated by the Maximum Cross Correlation(MCC) method and an inverse method from AVHRR/SST. In the results of MCC, discontinuous flow fields were estimated in the case that cross correlation coefficient was above 0.5 but these flow pattern disappeared when cross correlation coefficient was above 0.9. This estimation was conspicuous near SST patterns of eddies. In the results of inverse method, flow field was continuous and eddy motion was estimated definitely but the velocity was overstimated in compared with MCC result over the area of small temperature gradient. This result may be due to temperature error included in SST calculated and spatial variation of heat flux.