• Title/Summary/Keyword: critical velocity

Search Result 831, Processing Time 0.031 seconds

Critical Heat Flux of an Impinging Water Jet on a Heated Surface with Boiling (비등을 수반하는 발열면에 충돌하는 수분류의 임계열유속에 관한 연구)

  • Lee, Jong-Su;Kim, Heuy-Dong;Choi, Kuk-Kwang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.485-494
    • /
    • 2000
  • The purpose of this paper is to investigate a critical heat flux(CHF) during forced convective subcooled and saturated boiling in free water jet system impinged on a rectangular heated surface. The surface is supplied with subcooled or saturated water through a rectangular jet. Experimental parameters studied are a width of heated surface, a height of supplementary water and a degree of subcooling. Incipient boiling point is observed in the temperature of 6${\~}8^{\circ}C$ of superheat of test specimen. CHF depends on jet velocity for various boiling-involved coolant system. CHF also is proportional to the nozzle exit velocity to the power of n, where n is 0.55 and 0.8 for subcooled and saturated boiling, respectively. CHF is enhanced with a higher jet velocity, higher degree of subcooling and smaller width of a heated surface.

An Experimental Work on Cross Flow Induced Vibration of Staggered Array Pipe Bundles (어긋난 배열 을 갖는 파이프 집합체 의 횡유동 관련 진동 에 관한 실험적 연구)

  • 박윤식;이진희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.24-30
    • /
    • 1985
  • An experimental work to predict critical flow velocity to give whirling instability on staggered array tube banks model which is located in wind tunnel is presented. The critical flow velocity was obtained by measuring flow induced tube vibration on three tube array models having different pitch to diameter ratio as changing damping ratio and natural frequency of tube model. The obtained experimental results are directly compared with the numbers of other investigators and partly proved the truth of Blevin's new idea to predict critical flow velocity.

Critical Fluid Velocity of Fluid-conveying Cantilevered Cylindrical Shells with Intermediate Support (중간 지지된 유체 유동 외팔형 원통셸의 임계유속)

  • Kim, Young-Wann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.422-429
    • /
    • 2011
  • The critical fluid velocity of cantilevered cylindrical shells subjected to internal fluid flow is investigated in this study. The fluid-structure interaction is considered in the analysis. The cantilevered cylindrical shell is supported intermediately at an arbitrary axial position. The intermediate support is simulated by two types of artificial springs: translational and rotational spring. It is assumed that the artificial springs are placed continuously and uniformly on the middle surface of an intermediate support along the circumferential direction. The steady flow of fluid is described by the classical potential flow theory. The motion of shell is represented by the first order shear deformation theory (FSDT) to account for rotary inertia and transverse shear strains. The effect of internal fluid can be considered by imposing a relation between the fluid pressure and the radial displacement of the structure at the interface. Numerical examples are presented and compared with existing results.

Vibration and instability analysis of pipes reinforced by SiO2 nanoparticles considering agglomeration effects

  • Golabchi, Hadi;Kolahchi, Reza;Bidgoli, Mahmood Rabani
    • Computers and Concrete
    • /
    • v.21 no.4
    • /
    • pp.431-440
    • /
    • 2018
  • Fluid velocity analysis on the instability of pipes reinforced by silica nanoparticles ($SiO_2$) is presented in this paper. Mori-Tanaka model is used for obtaining the effective materials properties of the nanocomposite structure considering agglomeration effects. The well known Navier-Stokes equation is used for obtaining the applied force of fluid to pipe. Based on the Reddy higher-order shear deformation theory, the motion equations are derived based on energy method and Hamilton's principal. The frequency and critical fluid velocity of structure are calculated using differential quadrature method (DQM) so that the effects of different parameters such as volume fractions of SiO2 nanoparticles, SiO2 nanoparticles agglomeration, boundary conditions and geometrical parameters of pipes are considered on the nonlinear vibration and instability of the pipe. Results indicate that increasing the volume fractions of SiO2 nanoparticles, the frequency and critical fluid velocity of the structure are increased. Furthermore, considering SiO2 nanoparticles agglomeration, decreases the frequency and critical fluid velocity of the pipe.

Flows Characteristics of Developing Turbulent Pulsating Flows in a curved Square Duct (곡관덕트내의 입구영역에서 난류 맥동유도의 유동특성)

  • 봉태근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.533-542
    • /
    • 1999
  • In this study the flow characteristics of developing turbulent pulsating flows in a square-sec-tional 180。 curved duct are investigated experimentally. The experimental study of air flow in a square-sectional curved duct is carried out to measure axial velocity distribution secondary flow velocity profiles and wall shear stress distributions by using a Laser Doppler Velocimetry system with the data acquisition and processing system of Rotating Machinery Resolver (RMR) and PHASE software at the entrance region of the duct which is divided into 7 sections from the inlet(${{\o}}=0_{\circ}$) to the outlet (${{\o}}=180_{\circ}$) in $30_{\circ}$ intervals. The results obtained from the study are summarized as follows: (1) The time-averaged critical Dean number of turbulent pulsating flow(De ta, cr) is greater than $75{\omega}+$ It is understood that the critical Dean number and the critical Reynolds number are related to the dimensionless angular frequency in a curved duct. (2) Axial velocity profiles of turbulent pulsating flows are of an annular type similar to those of turbulent stead flows. (3) Secondary flows of trubulent pulsating flows are strong and complex at the entrance region. As velocity amplitudes(A1) become larger secondary flows become stronger. (4) Wall shear stress distributions of turbulent pulsating flows in a square-sectional $180_{\circ}$ curved duct are exposed variously in the outer wall and are stabilized in the inner wall without regard to the phase angle.

  • PDF

3D Dynamics of the Oscillating-Moving Load Acting in the Interior of the Hollow Cylinder Surrounded with Elastic Medium

  • Akbarov, Surkay D.;Mehdiyev, Mahir A.
    • Structural Engineering and Mechanics
    • /
    • v.71 no.6
    • /
    • pp.713-738
    • /
    • 2019
  • In the paper the dynamics of the oscillating moving load acting in the interior of the hollow cylinder surrounded with elastic medium is studied within the scope of the exact field equations of 3D elastodynamics. It is assumed that the oscillating load act on the certain arc of the internal circle of the cylinder's cross section and this load moves with constant velocity along the cylinder's axis. The corresponding 3D dynamic problem is solved by employing moving coordinate system, the exponential Fourier transform and the presentation these transforms with the Fourier series. The expressions of the transforms are determined analytically, however their originals are found numerically. Under the investigations carried out in the paper the main attention is focused on the so-called "gyroscopic effect", according to which, the influence of the vibration frequency on the values of the critical velocity and interface stresses are determined. Numerical results illustrated this effect are presented and discussed. In particular, it is established how the non-axisymmetricity of the problem acts on the influence of the load oscillation on its critical velocity and on the interface stresses.

Fluidelastic instability of a tube array in two-phase cross-flow considering the effect of tube material

  • Liu, Huantong;Lai, Jiang;Sun, Lei;Li, Pengzhou;Gao, Lixia;Yu, Danping
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.2026-2033
    • /
    • 2019
  • Fluidelastic instability of a tube array is a key factor of the security of a nuclear power plant. An unsteady model of the fluidelastic instability of a tube array subjected to two-phase flow was developed to analyze the fluidelastic instability of tube bundles in two-phase flow. Based on this model, a computational program was written to calculate the eigenvalue and the critical velocity of the fluidelastic instability. The unsteady model and the program were verified by comparing with the experimental results reported previously. The influences of void fraction and the tube's material properties on the critical velocity were investigated. Numerical results showed that, with increasing the void fraction of the two-phase flow, the tube array becomes more stable. The results indicate that the critical velocities of the tube array made of stainless are much higher than those of the other two tube arrays within void fraction ranging from 20% to 80%.

A Study on the Behavior of Droplets Colliding with Parallel Wires (평행 와이어와 충돌하는 액적 거동에 관한 연구)

  • Na, J.K.;Noh, D.H.;Jung, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.26 no.3
    • /
    • pp.149-156
    • /
    • 2021
  • In this study, the behavior of the droplet colliding with parallel wires was analyzed by time-delay photography. The impact behavior modes and the critical capture speed were analyzed by changing fluids, the droplet velocity, the wire diameter and the distance between wires. Seven typical modes of impacting droplet on parallel wires were observed. The tendency of mode change was generally similar when the wire diameter was changed, but the increase of the wire diameter caused the increase of the droplet velocity at which the mode changed. The modes at the highest droplet velocity were the splitting mode when the wires were closest, the passing and splitting mode in the middle, and the passing mode when the wires were farthest apart. The critical capture speed increased as the wire diameter increased and the distance between wires decreased. The ethanol droplet showed the lowest critical capture speed.

A Study on Velocity Profiles and Critical Dean Number of Developing Transitional Unsteady Flows in a Curved Duct (곡관덕트의 입구영역에서 천이비정상유동의 속도분포와 임계딘수에 관한연구)

  • 이행남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.862-870
    • /
    • 1998
  • In this paper an experimental investigation of characteristics of developing transitional unsteady flows in a square-sectional 180。 curved duct are presented. The experimental study using air is carried out to measure axial velocity profiles secondary flow velocity profiles and entrance length by using Laser Do ppler Velocimeter(LDV) system. The flow development is found to depend upon Dean number dimensionless angular frequency velocity amplitude ration and cur-vature ratio. Of special interest is the secondary flow generated by centrifugal effects in the plane of the cross-section of the duct. The secondary flows are strong and complicate at entrance region. The entrance length of transitional pulsating flow is obtained to 120。 of bended angle of duct in this experimental conditions.

  • PDF

The Vibration Analysis of Pipes Conveying Fluid with Several Harmonic Pulsations (여러 개의 조화맥동을 갖는 유체를 운반하는 파이프의 진동 해석)

  • Jeong, Seok-Hyen;Seo, Young-Soo;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1077-1082
    • /
    • 2004
  • It is well known that the pipe will be unstable if the fluid velocity is higher than critical velocity. But even if the velocity of the fluid below the critical velocity, resonance will be caused by pulsation of the fluid. So, many people has studied about the piping system vibration due to a fluid pulsation. But almost guess that fluid has only one hamonic pulsation. Actually, like this case is rare quite. So, in this paper, we consider the vibration analysis of a pipe conveying fluid with several harmonic pulsations and compare the result which considers one hamonic pulsation with the result which considers several harmonic pulsations. And we verify the result in time domain again.

  • PDF