• Title/Summary/Keyword: critical response

Search Result 1,639, Processing Time 0.037 seconds

A Study on Comparison of Combination Rules for the Seismic Analysis on Curved Bridges with the Different Radiuses of Curvature (곡선교의 내진 해석 시 곡률에 따른 하중 조합 방법의 비교에 관한 연구)

  • Ryu, Dong-Hyeon;Shin, Myoung-Gyu;Park, Jin-Wan;Kim, Moon-Kyum
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.567-572
    • /
    • 2008
  • This paper's purpose is to improve determining of the critical response of curved bridge to multi-component seismic motion. There are several methods to combine responses by multi-component excitation response, 30%, 40% rules and square-root-of-sum (SRSS). These combination rules determine same value of critical response in straight bridges. However, each method has critical response value of different magnitude in curved bridges. Thus a study about critical response of curved bridges is required. This paper presents comparison critical responses value as each combination rule, 30%, 40% rules and SRSS on curved bridges with the different radiuses of curvature. This study was carried out by response spectrum analysis of OO IC steel box girder bridge using SAP2000. It is concluded as follows: 1) In curved bridges, 30% and 40% rules tend to underestimate the critical response relatively to SRSS. 2) When bridges have smaller radiuses than 100m, difference between SRSS and 30% or 40% rules let run errors up as radiuses of curvature decreased.

  • PDF

Use of near-fault pulse-energy for estimating critical structural responses

  • Chang, Zhiwang;Liu, Zhanhui;Chen, Zhenhua;Zhai, Changhai
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.415-423
    • /
    • 2019
  • Near-fault ground motions can impose particularly high seismic demands on structures due to the pulses that are typically observed in the velocity time-histories. In this study it is empirically found that the critical response can be estimated from the directions corresponding to the maximum (max) or minimum (min) pulse-energy. Determination of the pulse-energy requires removing of the high-frequency content. For achieving this, the wavelet analysis and the least-square-fitting (LSF) algorithm are adopted. Results obtained by the two strategies are compared and differences between them are analyzed. Finally, the relationship between the critical response and the response derived from directions having the max or min pulse-energy confirms that using the pulse-energy for deriving the critical response of the building structures is reasonable.

Generation of critical and compatible seismic ground acceleration time histories for high-tech facilities

  • Hong, X.J.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.6
    • /
    • pp.687-707
    • /
    • 2007
  • High-tech facilities engaged in the production of semiconductors and optical microscopes are extremely expensive, which may require time-domain analysis for seismic resistant design in consideration of the most critical directions of seismic ground motions. This paper presents a framework for generating three-dimensional critical seismic ground acceleration time histories compatible with the response spectra specified in seismic design codes. The most critical directions of seismic ground motions associated with the maximum response of a high-tech facility are first identified. A new numerical method is then proposed to derive the power spectrum density functions of ground accelerations which are compatible with the response spectra specified in seismic design codes in critical directions. The ground acceleration time histories for the high-tech facility along the structural axes are generated by applying the spectral representation method to the power spectrum density function matrix and then multiplied by envelope functions to consider nonstationarity of ground motions. The proposed framework is finally applied to a typical three-story high-tech facility, and the numerical results demonstrate the feasibility of the proposed approach.

Combination rules and critical seismic response of steel buildings modeled as complex MDOF systems

  • Reyes-Salazar, Alfredo;Valenzuela-Beltran, Federico;de Leon-Escobedo, David;Bojorquez-Mora, Eden;Barraza, Arturo Lopez
    • Earthquakes and Structures
    • /
    • v.10 no.1
    • /
    • pp.211-238
    • /
    • 2016
  • The Maximum seismic responses of steel buildings with perimeter moment resisting frames (MRF), modeled as complex MDOF systems, are estimated for several incidence angles of the horizontal components and the critical one is identified. The accuracy of the existing rules to combine the effects of the individual components is also studied. Two and three components are considered. The critical response does not occur for principal components and the corresponding incidence angle varies from one earthquake to another. The critical response can be estimated as 1.40 and 1.10 times that of the principal components, for axial load and interstory shears, respectively. The rules underestimate the axial load but reasonably overestimate the shears. The rules are not always inaccurate in the estimation of the combined response for correlated components. On the other hand, totally uncorrelated (principal) components are not always related to an accurate estimation. The correlation of the individual effects (${\rho}$) may be significant, even for principal components. The rules are not always associated to an inaccurate estimation for large values of ${\rho}$, and small values of ${\rho}$ are not always related to an accurate estimation. Only for perfectly uncorrelated harmonic excitations and elastic analysis of SDOF systems, the individual effects of the components are uncorrelated and the rules accurately estimate the combined response. The degree of correlation of the components, the type of structural system, the response parameter under consideration, the location of the structural member and the level of structural deformation must be considered while estimating the level of underestimation or overestimation.

Unit Response Optimizer mode Design of Ultra Super Critical Coal-Fired Power Plant based on Fuzzy logic & Model Predictive Controller (퍼지 로직 및 모델 예측 제어기 적용을 통한 초초임계압 화력발전소 부하 응답 최적화 운전 방법 설계)

  • Oh, Ki-Yong;Kim, Ho-Yol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2285-2290
    • /
    • 2008
  • Even though efficiency of coal-fired power plant is proportional to operating temperature, increasement of operating temperature is limited by a technological level of each power plant component. It is an alternative plan to increase operating pressure up to ultra super critical point for efficiency enhancement. It is difficult to control process of power plant in ultra super critical point because that point has highly nonlinear characteristics. In this paper, new control logic, Unit Response Optimizer Controller(URO Controller) which is based on Fuzzy logic and Model Predictive Controller, is introduced for better performance. Then its performance is tested and analyzed with design guideline.

Factors Associated with Indacaterol Response in Tuberculosis-Destroyed Lung with Airflow Limitation

  • Kim, Tae Hoon;Rhee, Chin Kook;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.82 no.1
    • /
    • pp.35-41
    • /
    • 2019
  • Background: Pulmonary tuberculosis can result in anatomical sequelae, and cause airflow limitation. However, there are no treatment guidelines for patients with a tuberculosis-destroyed lung. Recently, indacaterol effectiveness in chronic obstructive pulmonary disease (COPD) patients with Tuberculosis history (INFINITY) study revealed indacaterol provided bronchodilation and symptom improvement in COPD patients with a tuberculosis-destroyed lung. Methods: We conducted a post-hoc subgroup analysis of the randomized controlled trial, the INFINITY study, to determine factors associated with indacaterol response in a tuberculosis-destroyed lung with airflow limitation. Data from 68 patients treated with inhaled indacaterol, were extracted and analyzed. Factors associated with the response of forced expiratory volume in one second ($FEV_1$) to indacaterol treatment, were determined using linear regression analysis. Results: Of 62 patients included, 68% were male, and 52% had history of cigarette smoking. Patients revealed mean $FEV_1$ of 50.5% of predicted value with mean improvement of 81.3 mL in $FEV_1$ after indacaterol treatment for 8 weeks. Linear regression analysis revealed factors associated with response of $FEV_1$ to indacaterol included a short duration of smoking history, and high short-acting bronchodilator response. When patients with history of smoking were excluded, factors associated with response of $FEV_1$ to indacaterol included high short-acting bronchodilator response, and poor health-related quality of life score as measured by St. George's Respiratory Questionnaire for COPD. Conclusion: In a tuberculosis-destroyed lung with airflow limitation, short-acting bronchodilator response and smoking history can play a critical role in predicting outcomes of indacaterol treatment.

The effect of nanoparticle in reduction of critical fluid velocity in pipes conveying fluid

  • Ghaitani, M.M.;Majidian, A.;Shokri, V.
    • Advances in concrete construction
    • /
    • v.9 no.1
    • /
    • pp.103-113
    • /
    • 2020
  • This paper deal with the critical fluid velocity response of nanocomposite pipe conveying fluid based on numerical method. The pressure of fluid is obtained based on perturbation method. The motion equations are derived based on classical shell theory, energy method and Hamilton's principle. The shell is reinforced by nanoparticles and the distribution of them are functionally graded (FG). The mixture rule is applied for obtaining the equivalent material properties of the structure. Differential quadrature method (DQM) is utilized for solution of the motion equations in order to obtain the critical fluid velocity. The effects of different parameters such asCNT nanoparticles volume percent, boundary conditions, thickness to radius ratios, length to radius ratios and internal fluid are presented on the critical fluid velocity response structure. The results show that with increasing the CNT nanoparticles, the critical fluid velocity is increased. In addition, FGX distribution of nanoparticles is the best choice for reinforcement.

Generation of synthetic accelerograms using a probabilistic critical excitation method based on energy constraint

  • Bazrafshan, Arsalan;Khaji, Naser
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.45-56
    • /
    • 2020
  • The application of critical excitation method with displacement-based objective function for multi degree of freedom (MDOF) systems is investigated. To this end, a new critical excitation method is developed to find the critical input motion of a MDOF system as a synthetic accelerogram. The upper bound of earthquake input energy per unit mass is considered as a new constraint for the problem, and its advantages are discussed. Considering this constraint, the critical excitation method is then used to generate synthetic accelerograms for MDOF models corresponding to three shear buildings of 10, 16, and 22 stories. In order to demonstrate the reliability of generated accelerograms to estimate dynamic response of the structures, three target ground motions with considerable level of energy contents are selected to represent "real critical excitation" of each model, and the method is used to re-generate these ground motions. Afterwards, linear dynamic analyses are conducted using these accelerograms along with the generated critical excitations, to investigate the key parameters of response including maximum displacement, maximum interstory drift, and maximum absolute acceleration of stories. The results show that the generated critical excitations can make an acceptable estimate of the structural behavior compared to the target ground motions. Therefore, the method can be reliably implemented to generate critical excitation of the structure when real one is not available.

An Analysis on Power Demand Reduction Effects of Demand Response Systems in the Smart Grid Environment in Korea

  • Won, Jong-Ryul;Song, Kyung-Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1296-1304
    • /
    • 2013
  • This study performed an analysis on power demand reduction effects exhibited by demand response programs, which are advanced from traditional demand-side management programs, in the smart grid environment. The target demand response systems for the analysis included incentive-based load control systems (2 month-ahead demand control system, 1~5 days ahead demand control system, and demand bidding system), which are currently implemented in Korea, and price-based demand response systems (mainly critical peak pricing system or real-time pricing system, currently not implemented, but representative demand response systems). Firstly, the status of the above systems at home and abroad was briefly examined. Next, energy saving effects and peak demand reduction effects of implementing the critical peak or real-time pricing systems, which are price-based demand response systems, and the existing incentive-based load control systems were estimated.

Rotordynamic Characteristics Analysis for API 610 BB5 Pump Development (API 610 BB5 펌프 개발을 위한 로터다이나믹 특성분석)

  • Kim, Byung-Ok;Lee, An-Sung;Kim, Sung-Ki
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.38-44
    • /
    • 2011
  • This paper deals with the detail rotordynamic analysis for BB5 eight stages pump as development of API 610 BB5 type pump. Dry-run analytical model, not considering operating fluid, and wet-run analytical model, considering operating fluid are established. In addition, plain circular and pressure dam bearings are chosen and it was discussed that each bearing has an effect on dynamic characteristics of pump rotor system. A rotordynamic analysis includes the critical speed map, Campbell diagram, stability, and unbalance response. As results, it was predicted that rated speed of the pump rotor passes through 1st critical speed in dry-run condition regardless of bearings, however, it was verified that, in wet-run condition, the rotor system doesn't have critical speeds even if more than twice rated speed. Hence the resonance problem caused by the critical speeds does not happen since actual operating is in wet-run condition including operating fluid. As a result of unbalance response analysis, the pump rotor has stable vibration response at rated speed, regardless of operating fluid and the proposed bearing types.