• Title/Summary/Keyword: critical means

Search Result 972, Processing Time 0.025 seconds

Application Management System with ZeroMQ and Alarms in Distribution Management System (배전운영 시스템에서의 ZeroMQ와 알람 정보를 이용한 운영기능 관리 시스템)

  • Kim, Pil-Seok;Kang, Ho-Young;Lim, Il-Hyung;Park, Jong-Ho;Shin, Yong-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1161-1167
    • /
    • 2015
  • Distribution Management System(DMS) ienhancing distribution automation system-based operation efficiency is an optimized system by various operational applications in a distribution network. DMS employs various applications like topology reconfiguration, volt/var control, and restoration at events such as overload, voltage violation, and a fault in a distribution system. An operation efficiency to employ multi-applications as restoration with short-term load forecasting is higher than a performance by a single application; and the applications are accomplished by an operator’s control. Applications’ combination is determined by various alarm information which means critical issues in order to operate a distribution system. Thus, this paper proposes an application management system which can configure application combination, control applications depending on alarm information and check their performance condition. The proposed application management system can be customized by operator easily and have high operation efficiency and reliability because it is worked by reviewed alarm information from operator.

A Study on Healing Environments and Evidence-Based Design - Focused on Healthcare Environments in the United States - (치유환경 연구문헌 고찰 및 근거중심디자인(Evidence-Based Design) 활성화에 관한 연구 - 미국 치유환경 연구사례를 중심으로 -)

  • Park, Jin Gyu Phillip
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.41-50
    • /
    • 2011
  • This paper assesses the evidence of the built environments' impact on patients' and staff's well-being. It also introduces evidence-based design (EBD) and discusses barriers and solutions for promoting EBD. EBD is an informed approach to design by improving design decisions based on best available knowledge. Designers should provide psychologically and physically supportive environments to promote occupants' well-being. There is increasing evidence that a poorly designed environment elicits negative feelings and stress. Better design will lead to better outcomes especially when it applied to a vulnerable population such as patients, children, and the elderly. Due to high demands of promoting patients' health, healthcare providers and professional designers have been searching for evidence to create healing environments. EBD has been well received in healthcare facilities design and is expanding to other types of environmental design such as educational and commercial design. Design firms should consider EBD as a value-added component of design to meet current and future challenges. It is important for designers to realize that engaging in EBD is not a rejection of creativity, but a means by which to scrutinize their design projects. With critical literature reviews on healing environments, there is sufficient evidence that well-designed environments can promote patients' and medical staff's health outcomes.

A Design of Differential Voltage Clamped VCO for Improved Characteristics of Operating Frequency (개선된 동작 주파수 특성을 갖는 차동 전압 클램프 VCO 설계)

  • Kim, D.G.;Oh, R.;Woo, Y.S.;Sung, Man-Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3181-3183
    • /
    • 2000
  • As the fact that the simple data of text and sound in early year have been changed to be high quality images and sounds. PLL(Phase-Locked Loop) system plays an important role in communication system. VCO(Voltage Controlled Oscillator) is the most important part in PLL system because it can have critical effects on operation of PLL. Recently, it has been raised the necessity of high speed and high accuracy circuit application. In this paper, a new differential voltage clamped VCO using negative-skewed path is suggested. Using a dual-delay scheme to implement the VCO, higher operation frequency and wider tuning are achieved simultaneously. The dual-delay scheme means that both the negative skewed delay paths and the normal delay paths exist in the same ring oscillator. The negative skewed delay paths decrease the unit delay time of the ring oscillator below the single inverter delay time. As a result, higher operation frequency can be obtained. The whole characteristics of VCO are simulated by using HSPICE. Simulation results show that the resulting operating frequencies are 50% higher than those obtainable from the conventional approaches.

  • PDF

Internal Model Control of UPS Inverter with Robustness of Calculation Time Delay and Parameter Variation (연산지연시간과 파라미터 변동에 강인한 UPS 인버터의 내부모델제어)

  • Park, Jee-Ho;Keh, Joong-Eup;Kim, Dong-Wan;An, Young-Joo;Park, Han-Seok;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.175-185
    • /
    • 2002
  • In this paper, a new fully digital current control method of UPS inverter, which is based on an internal model control, is proposed. In the proposed control system, overshoots and oscillations due to the computation time-delay are compensated by explicit incorporation of the time-delay in the current control loop transfer function. The internal model controller is adopted to a second order deadbeat reference-to-output response which means that its response reaches the reference in two sampling time including computational time-delays. That is, the average current of filter capacitor is been exactly equal to the reference current with a time lag of two sampling intervals. Therefore, this method has an essentially overshoot free reference-to-output response with a minimum possible rise time. The effectiveness of the proposed control system has been verified by the simulation and experimental respectively. From the simulation and experimental results, the proposed system is achieved the robust characteristics to the calculation time delay and parameter variation as well as very fast dynamic performance, thus it can be effectively applied to the power supply for the critical load.

Electrical and Mechanical Properties in High Tc Superconducting Wires for HTSC Cable (고온 초전도 케이블용 선재의 특성해석에 관한 연구)

  • Kim, Sang-Hyun;Jang, Hyun-Man;Jeong, Jong-Man;Kim, Young-Seok;Baek, Seung-Myong
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.702-705
    • /
    • 1998
  • To be applied to electrical equipment HTSC tapes have to endure external stress and so on. The critical current density has been shown depending on the mechanical properties, strain and bending stress. AC loss reduction is primary concern in the development of such high-efficiency equipment. AC losses in Bi-2223 silver-sheathed tapes, both single and multi-filamentary, were investigated by means of AC magnetization techniques. The results were compared with the hysteresis loss equation based on Bean model and the eddy current loss equation. The AC loss of the mono-filamentary tape was the hysteresis. On the contrary, the AC loss of the multi-filamentary tape was substantially dominated by the eddy current loss in the Ag matrix.

  • PDF

Effect of NaCl on the Mixed Micellar Properties of Sodium Dodecyl Sulfate(SDS) with Tetraethylene Glycol Monododecyl Ether(TGME) (Sodium Dodecyl Sulfate(SDS)와 Tetraethylene Glycol Monododecyl Ether(TGME)의 혼합미셀화에 미치는 NaCl의 효과)

  • Lee, Byung-Hwan
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.896-901
    • /
    • 1995
  • The critical micelle concentrations(CMC$^*$) of the mixed surfactant systems of Sodium dodecyl sulfate(SDS) with Tetraethylene glycol monododecyl ether(TGME) in the aqueous solutions of NaCl at $25^{\circ}C$ were determined as a function of the overall mole fraction of $SDS(\alpha1)$ by the use of surface tension method. Various thermodynamic parameters for the micellization of SDS/TGME mixed surfactant systems were calculated and analyzed by means of the equations derived from the nonideal mixed micelle model, based on the pseudo-phase separation model.

  • PDF

Direct assignment of the dynamics of a laboratorial model using an active bracing system

  • Moutinho, C.;Cunha, A.;Caetano, E.
    • Smart Structures and Systems
    • /
    • v.8 no.2
    • /
    • pp.205-217
    • /
    • 2011
  • This article describes the research work involving the implementation of an Active Bracing System aimed at the modification of the initial dynamics of a laboratorial building structure to a new desired dynamics. By means of an adequate control force it is possible to assign an entirely new dynamics to a system by moving its natural frequencies and damping ratios to different values with the purpose of achieving a better overall structural response to external loads. In Civil Engineering applications, the most common procedures for controlling vibrations in structures include changing natural frequencies in order to avoid resonance phenomena and increasing the damping ratios of the critical vibration modes. In this study, the actual implementation of an active system is demonstrated, which is able to perform such modifications in a wide frequency range; to this end, a plane frame physical model with 4 degrees-of-freedom is used. The Active Bracing System developed is actuated by a linear motor controlled by an algorithm based on pole assignment strategy. The efficiency of this control system is verified experimentally by analyzing the control effect obtained with the modification of the initial dynamic parameters of the plane frame and observing the subsequent structural response.

Medical Ethics Education: Its Objectives and Curriculum (의료윤리교육의 목적 및 과정에 대한 고찰)

  • Lee, Ilhak
    • Korean Medical Education Review
    • /
    • v.16 no.3
    • /
    • pp.147-155
    • /
    • 2014
  • Medical ethics has been integrated into the curriculum for medical education in Korea for over 30 years now. There have been many attempts to establish standards for the educational objectives and curriculum, including establishing learning outcomes and publishing medical ethics textbooks in Korean. However, this task is not easy for several reasons: the interdisciplinary nature of the subject, educators' lack of experience, and the lack of a consensus on the criteria that would be effective educational goals. In this article, the author explores (1) the need for reflection on the education itself, (2) two perspectives of medical ethics education, (3) critical perspectives on the effectiveness of the current medical ethics education, and (4) the variety of modalities of medical ethics education. Further, the author proposes a way to teach medical ethics in Korea. The contents and means are closely related to the question of philosophy of medical education: "Should professional ethics education be 'realistic' or 'idealistic'?" Ethics requires educators to be open to new learning experiences and to ethical development. Medical Ethics education should be relevant to everyday clinical experiences and, at the same time provide students and educators to critically review their ethical perspective through reflections.

Development of a Magnetic Seal and the Leak Test (마그네틱씰 개발 및 기밀 평가 시험)

  • Kim, Ock-Hyun;Lee, Min-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.79-83
    • /
    • 2011
  • Magnetic seal uses a magnetic fluid to seal a gap between a rotating shaft and housing. It is distinguished from other kinds of seals from the fact that solid contact does not occur in the seal. This implies that it is free from solid rubbing thus dustless and provides a clean circumstance. That is the reason why the magnetic seal is used exclusively for most of vacuum chambers in semiconductor process where dustless clean circumstance is critical. A magnetic seal has been developed of which design parameters are determined based on published data, and an air pressure test has been done to examine its sealing capability. Effects of some design parameters have been studied through FEM analysis. The results show some notable aspects of design parameters and provide suggestions for developing the seals. Regarding the sealing capacity of the magnetic seal the factor to match the theoretical value with the actual one was found to be 0.4~0.7, which means still there is some discrepancy between theory and actual.

A Novel Optical High-Availability Seamless Redundancy (OHSR) Design Based on Beam Splitting / Combining Techniques

  • Altaha, Ibraheem Raed;Kim, Sung Chul;Rhee, Jong Myung
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.678-685
    • /
    • 2016
  • The standard high-availability seamless redundancy (HSR) protocol utilizes duplicated frame copies of each sent frame for zero fail over time. This means that even in cases of a node or link failure, the destination node will receive at least one copy of the sent frame, resulting in no network downtime. However, the standard HSR is mostly based on the electrical signal connection inside the node, which leads to the production of considerable latency at each node due to frame processing. Therefore, in a large scale HSR ring network, the accumulated latencies become significant and can often restrict the mission-critical real-time application of HSR. In this paper, we present a novel design for optical HSR (OHSR) that uses beam splitting/combining techniques. The proposed OHSR passes the frames directly to adjacent nodes without frame processing at each node, thereby theoretically generating no latency in any node. Various simulations for network samples, made to validate the OHSR design and its performance, show that the OHSR outperforms the standard HSR.