• Title/Summary/Keyword: critical current ratio

Search Result 174, Processing Time 0.039 seconds

Design of HTS Current Lead for SMES Magnet (SMES 마그네트용 고온초전도 전류도입선 설계)

  • Jang, Hyeon-Man;O, Sang-Su;Jo, Jeon-Uk;Jo, Yeong-Sik;Ha, Hong-Su;Ha, Dong-U;Seong, Gi-Cheol;Gwon, Yeong-Gil;Ryu, Gang-Sik;Kim, Sang-Hyeon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.6-10
    • /
    • 2000
  • 1.5 kA class HTS current leads for a SMES magnet, which are connected to a conventional vapor cooled copper leads, were designed. The HTS leads are composed of Bi-2223/Ag-Au tapes and a stainless stell tube. The estimated critical current of the lead is about 1.6 kA at 77.3 K and in a self magnetic field, and the heat input to the liquid helium from the cold end of the 35 cm lead is 0.4 W/lead. It has been made clear that the heat input decreases with increase of the lead length and decrease of the warm end temperature and Ag-Au/SC ratio.

  • PDF

Mitigation of wind-induced responses of cylinder solar tower by a tiny eddy current tuned mass damper based on elastic wind tunnel tests

  • Liu, Min;Li, Shouying;Chen, Zhengqing
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.619-629
    • /
    • 2020
  • Solar towers, which often has a large aspect ratio and low fundamental natural frequency, were extremely prone to large amplitude of wind-induced vibrations, especially Vortex-Induced Vibration (VIV). A tiny Tuned Mass Damper (TMD) with conveniently adjustable eddy current damping was specially designed and manufactured for elastic wind tunnel tests of a solar tower. A series of numerical simulations by using the COMSOL software were conducted to determine three key parameters, including the thickness of the back iron plate and the conductive plate (Tb and Tc), the distance between the magnet and the conductive plate (Td). Based on the results of numerical simulations, a tiny TMD was manufactured and its structural parameters were experimentally identified. The optimized values of the tiny TMD can be conveniently realized. The tiny TMD was installed at the top of the elastic test model of a 243-meter-high solar tower, and a series of wind tunnel tests were carried out to examine the effectiveness of the TMD in suppressing wind-induced responses of the test model. The results showed that the wind-induced responses could be obviously reduced by the TMD, especially in the cross-wind direction. The cross-wind RMS and peak responses at the critical wind velocity can be reduced by about 86% and 75%, respectively. However, the maximum reduction of the responses at the design wind velocity is about 45%, obviously less than that at the critical wind velocity.

Current Status of Pediatric Critical Care in Korea: Results of 2015 National Survey

  • Yoon, Jong-seo;Jhang, Won Kyoung;Choi, Yu Hyeon;Lee, Bongjin;Kim, Yoon Hee;Cho, Hwa Jin;Eun, Byung Wook;Kim, Jintae;Kim, Kyung Won;Cho, Joongbum;Shin, Hong Ju;Ryu, Jeong Min;Chung, Jae Hee;Yoo, Young;Huh, June;Park, Seong Jong;Park, June Dong;Korean Society of Pediatric Critical Care Medicine
    • Journal of Korean Medical Science
    • /
    • v.33 no.49
    • /
    • pp.308.1-308.10
    • /
    • 2018
  • Background: The aim of this study was to describe the structure, organization, management, and staffing of pediatric critical care (PCC) in Korea. Methods: We directed a questionnaire survey for all Upper Grade General Hospitals (n = 43) in Korea in 2015. The first questionnaire was mainly about structure, organization, and staffing and responses were obtained from 32 hospitals. The second questionnaire was mainly about patients and management. Responses to second questionnaire were obtained from 18 hospitals. Results: Twelve from 32 Upper Grade General Hospitals had pediatric intensive care units (PICUs) and 11 of them had the PICU which was exclusive for children. Total number of PICU beds in Korea was 113. The ratio of the number of PICU beds to the number of children was 1:77,460 in Korea and this ratio is lower than that of other developed countries. The mean number of beds in the PICUs was $9.4{\pm}9.3$ (range, 2-30). There were 16 medical doctors who were assigned for PCC and only 5 of them were full time pediatric intensivists. In the 18 Upper Grade General Hospitals that responded to the second questionnaire survey, there were 97 patients in the PICUs with an average number of $5.7{\pm}7.2$ (range, 0-22) on the survey day. The mean age of the patients was $3.4{\pm}5.6$ years. The mean length of hospital stay was $82{\pm}271days$. The mean Pediatric Risk of Mortality score III was $9.4{\pm}7.8$ at the time of admission to the PICUs. Conclusion: There is a considerable shortage of PICU beds compared to those in developed countries. In addition, the proportion of PICUs with PCC specialists is much lower than those in the US and European countries.

Contributors of the Severity of Airflow Limitation in COPD Patients

  • Hong, Yoon-Ki;Chae, Eun-Jin;Seo, Joon-Beom;Lee, Ji-Hyun;Kim, Eun-Kyung;Lee, Young-Kyung;Kim, Tae-Hyung;Kim, Woo-Jin;Lee, Jin-Hwa;Lee, Sang-Min;Lee, Sang-Yeub;Lim, Seong-Yong;Shin, Tae-Rim;Yoon, Ho-Il;Sheen, Seung-Soo;Ra, Seung-Won;Lee, Jae-Seung;Huh, Jin-Won;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Background: Although airway obstruction in chronic obstructive pulmonary disease (COPD) is due to pathologic processes in both the airways and the lung parenchyma, the contribution of these processes, as well as other factors, have not yet been evaluated quantitatively. We therefore quantitatively evaluated the factors contributing to airflow limitation in patients with COPD. Methods: The 213 COPD patients were aged >45 years, had smoked >10 pack-years of cigarettes, and had a post-bronchodilator forced expiratory volume in one second ($FEV_1$)/forced vital capacity (FVC) <0.7. All patients were evaluated by medical interviews, physical examination, spirometry, bronchodilator reversibility tests, lung volume, and 6-minute walk tests. In addition, volumetric computed tomography (CT) was performed to evaluate airway wall thickness, emphysema severity, and mean lung density ratio at full expiration and inspiration. Multiple linear regression analysis was performed to identify the variables independently associated with $FEV_1$ - the index of the severity of airflow limitation. Results: Multiple linear regression analysis showed that CT measurements of mean lung density ratio (standardized coefficient ${\beta}$=-0.46; p<0.001), emphysema severity (volume fraction of the lung less than -950 HU at full inspiration; ${\beta}$=-0.24; p<0.001), and airway wall thickness (mean wall area %; ${\beta}$=-0.19, p=0.001), as well as current smoking status (${\beta}$=-0.14; p=0.009) were independent contributors to $FEV_1$. Conclusion: Mean lung density ratio, emphysema severity, and airway wall thickness evaluated by volumetric CT and smoking status could independently contribute to the severity of airflow limitation in patients with COPD.

Effects of the length of linkers in metal-azobenzene-metal junction on transmission and ON/OFF ratio

  • Yeo, Hyeonwoo;Kim, Han Seul;Kim, Yong-Hoon
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.499-505
    • /
    • 2017
  • Photoisomerizing molecules which can transform their structure by the light irradiation have great deal for the application of photo-switching devices. And azobenzene is the representive type of the photoisomerizing molecules. It can transform their trans- structures into cis- structure as the light for certain wave lengths they receive. This property shows the potential of ON/OFF switching functionalization which can be used into the nano scale photo switch. Furthermore, many studies are interested in the organic linkers that connect the azobenzene and metal electrodes. We used S, $CH_2S$, $(CH_2)_4S$ as the linker to watch the influence of linkers for electronic properties. So We suggest a photoswitching device based on the vertical junction using the first-principles calculations with density functional theory and non-equilibrium Greens function (NEGF). By analyzing the electronic structure and tunneling current caused by the structural difference of the system between cis- and trans- azobenzene, the difference in switching mechanism, ON/OFF ratio and transmission will be watched as the linker changes. And finally We will suggest which linker would be the better for the optimal device architecture which can achieve high control of the ON/OFF photocurrent ratio. This result will show the potential of azobenzene-based photoswitch and provide the critical insight in constructing the optimal device architecture.

  • PDF

A new four-unknown equivalent single layer refined plate model for buckling analysis of functionally graded rectangular plates

  • Ibrahim Klouche Djedid;Sihame Ait Yahia;Kada Draiche;Emrah Madenci;Kouider Halim Benrahou;Abdelouahed Tounsi
    • Structural Engineering and Mechanics
    • /
    • v.90 no.5
    • /
    • pp.517-530
    • /
    • 2024
  • This paper presents a new four-unknown equivalent single layer (ESL) refined plate theory for the buckling analysis of functionally graded (FG) rectangular plates with all simply supported edges and subjected to in-plane mechanical loading conditions. The present model accounts for a parabolic variation of transverse shear stress over the thickness, and accommodates correctly the zero shear stress conditions on the top and bottom surfaces of the plate. The material properties are supposed to vary smoothly in the thickness direction through the rules of mixture named power-law gradation. The governing equilibrium equations are formulated based on the total potential energy principle and solved for simply supported boundary conditions by implementing the Navier's method. A numerical result on elastic buckling using the current theory was computed and compared with those published in the literature to examine the accuracy of the proposed analytical solution. The effects of changing power-law exponent, aspect ratio, thickness ratio and modulus ratio on the critical buckling load of FG plates under different in-plane loading conditions are investigated in detail. Moreover, it was found that the geometric parameters and power-law exponent play significant influences on the buckling behavior of the FG plates.

Design and Simulation Technologies of Flat Transformer with High Power Current (대전류 출력형 Flat Transformer 설계 및 해석 기술)

  • Han, Se-Won;Cho, Han-Goo;Woo, Bung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

Numerical Simulation of Cone Penetration Tests in Sand Ground Using Critical State Mohr Coulomb Plasticity Model (한계상태 Mohr Coulomb 소성 모델을 활용한 콘관입시험의 수치적 모사)

  • Woo, Sang Inn;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.2
    • /
    • pp.37-51
    • /
    • 2019
  • This study focuses on the numerical simulations of the cone penetration tests in a sand ground. The mechanical responses of sand were described using the modified Mohr Coulomb plasticity model based on the critical state soil mechanics. In the plasticity model, the dilatancy angle was not a constant, but a function of the distance to the critical state line from the current state of void ratio and mean effective stress. To simulate cone penetration tests numerically, this study relied on Lagrangian finite element method under the axisymmetric condition. To enable penetration of the cone penetrometer without tearing elements along the symmetric axis, the penetration guide concept was adopted in this study. The results of numerical simulations on the calibration chamber cone penetration tests had good agreement with the experimental results.

Design of Crooked Wire Antennas for UHF Band RFID Reader (UHF 대역 RFID 리더용 Crooked Wire 안테나 설계)

  • Choo Jae-Yul;Choo Ho-Sung;Park Ik-Mo;Oh Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.5 s.96
    • /
    • pp.472-481
    • /
    • 2005
  • This paper reports the design of RFID reader antennas working in UHF band. The reader antennas were designed using a Pareto Genetic Algorithm(Pareto GA). Antennas were optimized to have circular polarization(CP) with less than 3 dB axial ratio, impedance matching with less than VSWR=2 within the frequency range of UHF, an adequate readable range, a restricted size(kr<2.22) considering the practical condition. After Pareto GA optimization, we selected and built the most suitable antenna design and compared the measured results to the simulations. Operating principle of the antenna was explained by investigating the amplitude and the phase of the induced current on the antenna body. We also researched the stability of the antenna with respect to the manufacturing error and studied the critical design parameters by applying the random error method on the antenna bent points.

Transport Properties of $MgB_2$ Films Grown by Hybrid Physical Chemical Vapor Deposition Method (HPCVD 방법으로 성장된 $MgB_2$ 박막의 수송 특성)

  • Kim, Hye-Young;Hwang, Tae-Jong;Kim, D.H.;Seong, Won-Kyung;Kang, W.N.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • We prepared four different $MgB_2$ films on $Al_2O_3$ by hybrid physical chemical vapor deposition method with thicknesses ranging from $0.65\;{\mu}m$ to $1.2\;{\mu}m$. X-ray diffraction patterns confirm that all the $MgB_2$ films are c-axis oriented perpendicular to $Al_2O_3$ substrates. The superconducting onset temperature of $MgB_2$ films were between 39.39K and 40.72K. The residual resistivity ratio of the $MgB_2$ films was in the range between 3.13 and 37.3. We measured the angle dependence of critical current density ($J_c$) and resistivity, and determined the upper critical field ($H_{c2}$) from the temperature dependence of the resistivity curves. The anisotropy ratios defined as the ratio of the $H_{c2}$ parallel to the ab-plane to that perpendicular to the ab-plane were in the range of 2.13 to 4.5 and were increased as the temperature was decreased. Some samples showed increase of $J_c$ and decrease of resistivity when a magnetic field in applied parallel to the c-axis. We interpret this angle dependence in terms of enhanced flux pinning due to columnar growth of $MgB_2$ along the c-axis.

  • PDF