• 제목/요약/키워드: critical current ratio

검색결과 174건 처리시간 0.022초

SMES 마그네트용 고온초전도 전류도입선 설계 (Design of HTS Current Lead for SMES Magnet)

  • 장현만;오상수;조전욱;조영식;하홍수;하동우;성기철;권영길;류강식;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.6-10
    • /
    • 2000
  • 1.5 kA class HTS current leads for a SMES magnet, which are connected to a conventional vapor cooled copper leads, were designed. The HTS leads are composed of Bi-2223/Ag-Au tapes and a stainless stell tube. The estimated critical current of the lead is about 1.6 kA at 77.3 K and in a self magnetic field, and the heat input to the liquid helium from the cold end of the 35 cm lead is 0.4 W/lead. It has been made clear that the heat input decreases with increase of the lead length and decrease of the warm end temperature and Ag-Au/SC ratio.

  • PDF

Mitigation of wind-induced responses of cylinder solar tower by a tiny eddy current tuned mass damper based on elastic wind tunnel tests

  • Liu, Min;Li, Shouying;Chen, Zhengqing
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.619-629
    • /
    • 2020
  • Solar towers, which often has a large aspect ratio and low fundamental natural frequency, were extremely prone to large amplitude of wind-induced vibrations, especially Vortex-Induced Vibration (VIV). A tiny Tuned Mass Damper (TMD) with conveniently adjustable eddy current damping was specially designed and manufactured for elastic wind tunnel tests of a solar tower. A series of numerical simulations by using the COMSOL software were conducted to determine three key parameters, including the thickness of the back iron plate and the conductive plate (Tb and Tc), the distance between the magnet and the conductive plate (Td). Based on the results of numerical simulations, a tiny TMD was manufactured and its structural parameters were experimentally identified. The optimized values of the tiny TMD can be conveniently realized. The tiny TMD was installed at the top of the elastic test model of a 243-meter-high solar tower, and a series of wind tunnel tests were carried out to examine the effectiveness of the TMD in suppressing wind-induced responses of the test model. The results showed that the wind-induced responses could be obviously reduced by the TMD, especially in the cross-wind direction. The cross-wind RMS and peak responses at the critical wind velocity can be reduced by about 86% and 75%, respectively. However, the maximum reduction of the responses at the design wind velocity is about 45%, obviously less than that at the critical wind velocity.

Current Status of Pediatric Critical Care in Korea: Results of 2015 National Survey

  • Yoon, Jong-seo;Jhang, Won Kyoung;Choi, Yu Hyeon;Lee, Bongjin;Kim, Yoon Hee;Cho, Hwa Jin;Eun, Byung Wook;Kim, Jintae;Kim, Kyung Won;Cho, Joongbum;Shin, Hong Ju;Ryu, Jeong Min;Chung, Jae Hee;Yoo, Young;Huh, June;Park, Seong Jong;Park, June Dong;Korean Society of Pediatric Critical Care Medicine
    • Journal of Korean Medical Science
    • /
    • 제33권49호
    • /
    • pp.308.1-308.10
    • /
    • 2018
  • Background: The aim of this study was to describe the structure, organization, management, and staffing of pediatric critical care (PCC) in Korea. Methods: We directed a questionnaire survey for all Upper Grade General Hospitals (n = 43) in Korea in 2015. The first questionnaire was mainly about structure, organization, and staffing and responses were obtained from 32 hospitals. The second questionnaire was mainly about patients and management. Responses to second questionnaire were obtained from 18 hospitals. Results: Twelve from 32 Upper Grade General Hospitals had pediatric intensive care units (PICUs) and 11 of them had the PICU which was exclusive for children. Total number of PICU beds in Korea was 113. The ratio of the number of PICU beds to the number of children was 1:77,460 in Korea and this ratio is lower than that of other developed countries. The mean number of beds in the PICUs was $9.4{\pm}9.3$ (range, 2-30). There were 16 medical doctors who were assigned for PCC and only 5 of them were full time pediatric intensivists. In the 18 Upper Grade General Hospitals that responded to the second questionnaire survey, there were 97 patients in the PICUs with an average number of $5.7{\pm}7.2$ (range, 0-22) on the survey day. The mean age of the patients was $3.4{\pm}5.6$ years. The mean length of hospital stay was $82{\pm}271days$. The mean Pediatric Risk of Mortality score III was $9.4{\pm}7.8$ at the time of admission to the PICUs. Conclusion: There is a considerable shortage of PICU beds compared to those in developed countries. In addition, the proportion of PICUs with PCC specialists is much lower than those in the US and European countries.

Contributors of the Severity of Airflow Limitation in COPD Patients

  • Hong, Yoon-Ki;Chae, Eun-Jin;Seo, Joon-Beom;Lee, Ji-Hyun;Kim, Eun-Kyung;Lee, Young-Kyung;Kim, Tae-Hyung;Kim, Woo-Jin;Lee, Jin-Hwa;Lee, Sang-Min;Lee, Sang-Yeub;Lim, Seong-Yong;Shin, Tae-Rim;Yoon, Ho-Il;Sheen, Seung-Soo;Ra, Seung-Won;Lee, Jae-Seung;Huh, Jin-Won;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권1호
    • /
    • pp.8-14
    • /
    • 2012
  • Background: Although airway obstruction in chronic obstructive pulmonary disease (COPD) is due to pathologic processes in both the airways and the lung parenchyma, the contribution of these processes, as well as other factors, have not yet been evaluated quantitatively. We therefore quantitatively evaluated the factors contributing to airflow limitation in patients with COPD. Methods: The 213 COPD patients were aged >45 years, had smoked >10 pack-years of cigarettes, and had a post-bronchodilator forced expiratory volume in one second ($FEV_1$)/forced vital capacity (FVC) <0.7. All patients were evaluated by medical interviews, physical examination, spirometry, bronchodilator reversibility tests, lung volume, and 6-minute walk tests. In addition, volumetric computed tomography (CT) was performed to evaluate airway wall thickness, emphysema severity, and mean lung density ratio at full expiration and inspiration. Multiple linear regression analysis was performed to identify the variables independently associated with $FEV_1$ - the index of the severity of airflow limitation. Results: Multiple linear regression analysis showed that CT measurements of mean lung density ratio (standardized coefficient ${\beta}$=-0.46; p<0.001), emphysema severity (volume fraction of the lung less than -950 HU at full inspiration; ${\beta}$=-0.24; p<0.001), and airway wall thickness (mean wall area %; ${\beta}$=-0.19, p=0.001), as well as current smoking status (${\beta}$=-0.14; p=0.009) were independent contributors to $FEV_1$. Conclusion: Mean lung density ratio, emphysema severity, and airway wall thickness evaluated by volumetric CT and smoking status could independently contribute to the severity of airflow limitation in patients with COPD.

Effects of the length of linkers in metal-azobenzene-metal junction on transmission and ON/OFF ratio

  • Yeo, Hyeonwoo;Kim, Han Seul;Kim, Yong-Hoon
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제6회(2017년)
    • /
    • pp.499-505
    • /
    • 2017
  • Photoisomerizing molecules which can transform their structure by the light irradiation have great deal for the application of photo-switching devices. And azobenzene is the representive type of the photoisomerizing molecules. It can transform their trans- structures into cis- structure as the light for certain wave lengths they receive. This property shows the potential of ON/OFF switching functionalization which can be used into the nano scale photo switch. Furthermore, many studies are interested in the organic linkers that connect the azobenzene and metal electrodes. We used S, $CH_2S$, $(CH_2)_4S$ as the linker to watch the influence of linkers for electronic properties. So We suggest a photoswitching device based on the vertical junction using the first-principles calculations with density functional theory and non-equilibrium Greens function (NEGF). By analyzing the electronic structure and tunneling current caused by the structural difference of the system between cis- and trans- azobenzene, the difference in switching mechanism, ON/OFF ratio and transmission will be watched as the linker changes. And finally We will suggest which linker would be the better for the optimal device architecture which can achieve high control of the ON/OFF photocurrent ratio. This result will show the potential of azobenzene-based photoswitch and provide the critical insight in constructing the optimal device architecture.

  • PDF

A new four-unknown equivalent single layer refined plate model for buckling analysis of functionally graded rectangular plates

  • Ibrahim Klouche Djedid;Sihame Ait Yahia;Kada Draiche;Emrah Madenci;Kouider Halim Benrahou;Abdelouahed Tounsi
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.517-530
    • /
    • 2024
  • This paper presents a new four-unknown equivalent single layer (ESL) refined plate theory for the buckling analysis of functionally graded (FG) rectangular plates with all simply supported edges and subjected to in-plane mechanical loading conditions. The present model accounts for a parabolic variation of transverse shear stress over the thickness, and accommodates correctly the zero shear stress conditions on the top and bottom surfaces of the plate. The material properties are supposed to vary smoothly in the thickness direction through the rules of mixture named power-law gradation. The governing equilibrium equations are formulated based on the total potential energy principle and solved for simply supported boundary conditions by implementing the Navier's method. A numerical result on elastic buckling using the current theory was computed and compared with those published in the literature to examine the accuracy of the proposed analytical solution. The effects of changing power-law exponent, aspect ratio, thickness ratio and modulus ratio on the critical buckling load of FG plates under different in-plane loading conditions are investigated in detail. Moreover, it was found that the geometric parameters and power-law exponent play significant influences on the buckling behavior of the FG plates.

대전류 출력형 Flat Transformer 설계 및 해석 기술 (Design and Simulation Technologies of Flat Transformer with High Power Current)

  • 한세원;조한구;우병철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

한계상태 Mohr Coulomb 소성 모델을 활용한 콘관입시험의 수치적 모사 (Numerical Simulation of Cone Penetration Tests in Sand Ground Using Critical State Mohr Coulomb Plasticity Model)

  • 우상인;정충기
    • 한국지반공학회논문집
    • /
    • 제35권2호
    • /
    • pp.37-51
    • /
    • 2019
  • 본 연구는 사질토 지반에서 수행되는 콘관입시험의 수치적 모사에 초점을 맞추고 있다. 지반은 한계상태 토질역학을 바탕으로 수정된 한계상태 Mohr Coulomb 소성 모델로 모사하였다. 한계상태 Mohr Coulomb 모델에서 팽창각은 상수가 아닌 현재상태와 한계상태 사이의 위상차의 함수로 표현된다. 수치적으로 콘관입시험은 대변위 해석을 요구하며, 이를 Lagrangian 유한요소법으로 해석하기 위해 관입 유도체 개념을 적용한 축대칭 조건 유한요소법을 이용하였다. 캘리브레이션 챔버에서 수행된 콘관입시험을 한계상태 Mohr Coulomb 모델을 이용하여 본 논문에서 제안된 유한 해석 기법을 적용한 결과, 실험 결과와 유사한 결과를 얻을 수 있었다.

UHF 대역 RFID 리더용 Crooked Wire 안테나 설계 (Design of Crooked Wire Antennas for UHF Band RFID Reader)

  • 주재율;추호성;박익모;오이석
    • 한국전자파학회논문지
    • /
    • 제16권5호
    • /
    • pp.472-481
    • /
    • 2005
  • 본 논문에서는 Pareto 유전자 알고리즘을 이용한 최적화기법을 적용하여 UHF 대역 내에서 동작하는 crooked wire 형태의 RFID 리더 안테나를 설계하였다. 최적화 과정은 안테나의 제한된 크기, 반사 손실 대역폭(VSWR<2), 원형 편파 대역폭(Axial Ratio<3 dB), 인식 영역이 실제 조건과 인식 영역에 부합하도록 수행하였다 최적화된 안테나들 중 표본 안테나를 제작하였으며, 리더 안테나 특성을 측정하여 시뮬레이션 결과와 비교 및 검증하였다. 안테나 동작원리를 안테나 선로에 유기된 전류를 분석하여 설명하였으며, 안테나의 구조적 민감도와 주요 설계 변수(critical design parameters)를 찾기 위해 랜덤 에러(random error) 방식을 안테나 본체의 선로가 꺾이는 부분에 적용한 후, 안테나 구조와 원형 편파 대역폭 및 안테나 반사 손실 대역폭 사이의 관계를 정량화 하였다.

HPCVD 방법으로 성장된 $MgB_2$ 박막의 수송 특성 (Transport Properties of $MgB_2$ Films Grown by Hybrid Physical Chemical Vapor Deposition Method)

  • 김혜영;황태종;김동호;성원경;강원남
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.5-10
    • /
    • 2007
  • We prepared four different $MgB_2$ films on $Al_2O_3$ by hybrid physical chemical vapor deposition method with thicknesses ranging from $0.65\;{\mu}m$ to $1.2\;{\mu}m$. X-ray diffraction patterns confirm that all the $MgB_2$ films are c-axis oriented perpendicular to $Al_2O_3$ substrates. The superconducting onset temperature of $MgB_2$ films were between 39.39K and 40.72K. The residual resistivity ratio of the $MgB_2$ films was in the range between 3.13 and 37.3. We measured the angle dependence of critical current density ($J_c$) and resistivity, and determined the upper critical field ($H_{c2}$) from the temperature dependence of the resistivity curves. The anisotropy ratios defined as the ratio of the $H_{c2}$ parallel to the ab-plane to that perpendicular to the ab-plane were in the range of 2.13 to 4.5 and were increased as the temperature was decreased. Some samples showed increase of $J_c$ and decrease of resistivity when a magnetic field in applied parallel to the c-axis. We interpret this angle dependence in terms of enhanced flux pinning due to columnar growth of $MgB_2$ along the c-axis.

  • PDF