Improvement Method for the Post-Management End System of a Landfill by Applying Total Pollutant Load Concept (오염총량 개념을 적용한 매립장 사후관리종료제도 개선 방안)

  • Chun, Seung-Kyu;Sim, Nak-Jong;Jeon, Eun-Jeong;Ryu, Don-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.22 no.2
    • /
    • pp.15-23
    • /
    • 2021
  • A method of improving the post-management end system of a landfill that reflected total pollutant load was applied to the SUDOKWON 1st Landfill Site. Modeling results showed that the ratio of remaining methane, when compared to the total maximum potential of 2,521 × 106 Nm3, was estimated to be 8.8% in 2020, 7.0% in 2030, and 6.5% in 2040. If the average oxidation rate of 89.1% in 2005-2019 was applied, the ratio decreased by 1.01% in 2020, 0.76% in 2030, and 0.70% in 2040. This suggests that if the amount of methane generated is all emitted from the surface of the landfill after 2025, the real amount emitted to the atmosphere is less than that in 2019; therefore, the post-management end is possible. According to the results of trend analysis of the quality of leachate water, effluent criteria for Biochemical Oxygen Demand (BOD) can be satisfied in 2024, while those for Chemical Oxygen Demand (COD) and Total Nitrogen (T-N) can be satisfied in 2047 and 2117, respectively. If the post-management end system changed based on total pollutant load, the post-management can be terminated BOD today and COD within a few years; however, the fact that T-N could be terminated only after 2041 shows the need to fundamentally change management methods.

A Study on the Planning Criteria for Thalassotherapy Facility (해양치유시설 계획기준에 관한 연구)

  • Lee, Han-Seok;Kang, Young-Hun;Seong, Hai-Min
    • Journal of Navigation and Port Research
    • /
    • v.44 no.1
    • /
    • pp.20-31
    • /
    • 2020
  • The purpose of this study was to provide planning criteria for the thalassotherapy facility. Among the various contents of the planning criteria, the crucial parts of the thalassotherapy facility planning are the location, facility environment, and room space. To do this, we first examined the characteristics of the thalassotherapy facility and inquired about the thalassotherapy resources and treatments that are the basis of the thalassotherapy facility planning. And then, the overseas qualification criteria related to thalassotherapy facility were analyzed. Based on the above research results, the criteria for the thalassotherapy facility planning on location, facility environment, and spaces of rooms are presented. The location is within 1km of the coastline, where there is no pollutant emission facility, and the climate conditions are maintained more than 80% throughout the year below 'caution' level of the thermal sensation index and sensory temperature. The water quality of the facility environment meets the stricter criteria among the domestic standards or ISO 17680 standards, and the air quality is 60% of the atmospheric environment standard of the 「Framework Act on Environmental Policy」 and SO2, NO2, O3 and PM10 concentration shall ensure that the annual number of exceeding standards meets the EU standard, and noise is less than 50dB per daytime, 40dB per night. Therapy spaces have to meet the standards of the 「Building Act」, the working standards of architectural planning and international standards according to their function and use.

Evaluation of Analytical Techniques for Some Gaseous Criteria Pollutants through a Field Measurement Campaign in Seoul, Korea (현장측정에 기초한 대기오염물질의 측정방식에 대한 비교연구-주요 기준성 오염물질을 중심으로)

  • 김세웅;김기현;김진석;이강웅;김경렬;문동민;김필수;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.403-415
    • /
    • 1999
  • To properly assess air pollution levels, application of quality assurance and quality control(QA/QC) is believed to be an essential step. In order to cope with such scientific principle, a field study was designed with an aim of comparing: 1) the methods of calibration for airborne pollutants and 2) the protocols developed for their measurements. Measurements were made at Han Yang University, Seoul during 29 May through 1 June 1998 under the management of the Division of Measurements and Analysis(DMA) of Korean Society for Atmospheric Environment(KOSAE). In this work, we report our results of intercomparative measurements on several gaseous criteria pollutants that were investigated mainly by the two institutes-Seoul National University(SNU) and the Korean Research Institute for Standards and Science(KRISS). Although measurements of major gaseous pollutants had been made routinely by many scientific institutes and organizations in Korea, most scientists involved in those studieswere obliged to do their experiments on the basis of their own procedural steps spaning from the preparation of gaseous standards to the methodological selections for the calibration. Hence, this campaign offered a unique opportunity to examine many important aspects on the measurements of these important gaseous pollutants. In the course of our study, we investigated the compatibility of data sets obtained by the two institutes in concert with reference data sets collected concurrently from a government-managed monitoring station. On the basis of our study, we conclude that different data sets made by different participants during this campaign agree well within the reasonable range of uncertainties.low, which indicated that during this period the potential acidity of precipitation was high but the neutralizing capacity was low. For Spring, pAi was very low but pH was slightly high. This was likely due to the large amount of $CaCO_3$ in the soil particles transported over a long range from the Chinese continent that were incorporated into the precipitation, and then neutralized the acidifying species with its high concentraton.

  • PDF

A Study on Construction of Eco-Industrial Complex by Industrial Symbiosis (연구노트 산업공생(Industrial Symbiosis)을 통한 생태산업공단 조성 방안)

  • 김좌관
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.177-183
    • /
    • 2000
  • This study is focused on the incustrial symbiosis based on industrial ecosystem theory. At first, the concept of industrial ecosystem was introduced. Industrial symbiosis is a good tool in order to make a harmony between industry and natural ecosystem. The good example of industrial symbiosis is the case of Kalundborg in Denmark, where 11 networks are working in four enterprises and one community nearby. It was proved that savings of natural resources and economic benefit are achieved by use of industrial symbiosis. Moreover, the control of pollutant emission was also done by use of advanced technology and investments. Based on this case. It was shown that industrial symbiosis through eco-industrial complex in Korea was confronted with many difficulties. First of all., loose emmision criteria, recycling system on wastes, and the absence of will for industrial symbiosis should be solved in Korea.

  • PDF

A Study on Characteristics of Water Quality in Wastewater according to the Washing of Municipal Solid Waste Incinerator (MSWI) Ash

  • Byun, Mi-Young;Kim, Hyung-Seok;Ahn, Ji-Whan;Kim, Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.296-300
    • /
    • 2001
  • In order to recycle the incineration ash (bottom ash and fly ash) generated from the incineration of municipal waste for a cement material, salts as well as heavy metal should be removed by the stabilization treatment. Most of these heavy metal and over 80% of salts are removed by a washing as a pre-treatment. However, wastewater which is another pollutant is generated by a washing, then proper treatment should be developed. First the characteristics of incineration ashes collected from two domestic full-sized incinerators were investigated and removal rate of salts and heavy metals from them also studied. The wastewater quality was compared to the criteria of the regulation by analyzing the characteristics of generated wastewater during the washing of incineration ash as a condition of liquid/solid ratio. Also, we tried to used this experimental results for the basic data to develop proper processing technique of municipal waste.

  • PDF

Long-term assessment of criteria pollutant concentrations determined by DOAS and conventional measurement techniques (DOAS system과 기존측정망 시스템의 장기관측결과 해석 : 반포지역을 중심으로 한 기준성가스 오염물질의 농도비교)

  • 김기현;김민영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.47-50
    • /
    • 2000
  • 대기 중에 존재하는 오염물질들을 광학적 원리에 기초하여 open path 방식으로 관측할 수 있는 Differential Optical Absorption Spectroscopy (이하 DOAS) 시스템은 대기오염관측의 기본적인 관념을 타파할 수 있는 하나의 대안으로 떠오르고 있다 (Lindqvist et al., 1990). 비록 아직까지 이러한 시스템으로 분석가능한 모든 관측대상물질들에 대한 검정방식의 객관성이 확보되지는 않고 있지만, $SO_2$, $O_3$, $NO_2$를 포함하는 일부 기준성 항목들의 경우 미국의 EPA나 독일의 TUV와 같은 기관들에 의해 공인받았을 정도로 측정방식의 객관성을 인정받는 추세에 있다. (중략)

  • PDF

A Study on Ozone Passive Sampler (II) -Interference and Field Application (오존간이 측정기에 대한 연구(II)-간섭현상 및 현장 적용성)

  • Jeong, Sang-Jin;Yang, Hee-Jun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.904-911
    • /
    • 2006
  • Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant ($SO_2,\;NO_2,\;CO$) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of $SO_2$ gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to $27.5^{\circ}C$ and relative humidity range from 48 to 84%.

Prediction of Water Quality of Youngwol Multipurpose Dam Using FEMWASP (FEMWASP 모형을 이용한 영월 다목적댐의 장래 수질 예측)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.443-452
    • /
    • 1998
  • The future water quality of Youngwol Dam was predicted using FEMWASP. In the this study, point and non-point source in the basin was investigated in detail, and future pollutant loading was computed by various prediction technique. The water quality of 29 sites was analyzed over four seasons. FEMWASP was used to predict future water quality of Youngwol lake and downstream of proposed dam. Future water quality of Youngwol lake was predicted to configure eutrophication status, management criteria was suggested to minimize the pollution problems coming from future eutrophication. Discharge rate of dam was decided as 30CMS to conserve the water quality, and overall design of dam was changed.

  • PDF

Effect of Climate Change and Urbanization on Flow and BOD Concentration Duration Curves (기후변화 및 도시화에 따른 유황곡선 및 BOD 농도지속곡선 변화)

  • Park, Kyung-Shin;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.12
    • /
    • pp.1091-1102
    • /
    • 2009
  • This study developed an integrated approach to climate change and urbanization impact assessment by linking models of SDSM (statistical downscaling model), HSPF (hydrological simulation program?Fortran) and ICM (impervious cover model). A case study of the Anyangcheon watershed illustrated how the proposed framework can be used to analyze the impacts of climate change and urbanization in terms of flood control, water security and water quality. The evaluation criteria were the variations of flow and pollutant concentration duration curves. In this study, nine scenarios including three climate (present condition, A1B and A2) and three urbanization scenarios were analyzed using HSPF model. As a result, climate change is a large influence on the flowrate and the urbanization affects the pollutant concentration. Therefore, the impacts of both climate change and urbanization must be included into the watershed management and water resources planning for sustainable development.

A Comparative Study on the Ambient Air Quality Standard Strength among Korea, the U.S.A. and the EU (우리나라, 미국 및 유럽의 대기환경기준 강도에 관한 비교 연구)

  • Park, Min-Bin;Lee, Tae-Jung;Lee, Eun-Sun;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.559-574
    • /
    • 2016
  • Based on air quality monitoring data ('10~'14) of Suwon City provided by the Korean Department of Environment, a fundamental statistic for 5 criteria pollutants such as $SO_2$, CO, $NO_2$, $O_3$, and $PM_{10}$ was initially investigated. The purpose of this paper was to review the ambient air quality standards(AAQS) of Korea, the U.S.A. and the EU and further to assess the degree of standard strength by the achievability of the AAQS comparing each national standard. Since the level and the way of standards for each air pollutant are various among countries, it is difficult to determine the degree of relative attainment using the same set of data above. Further when all the areas having bad air quality for a specific pollutant are classified as non-attainment case, it is more difficult to assess the degree of standard strength. Thus we introduced a new concept called the average concentration distance (ACD) to quantitatively estimate the strength. As results, the Korean 1-hr $NO_2$ AAQS is slightly stronger than the US standard and weaker than the EU standard. The Korean $O_3$ standard is strongest; however, the Korean $PM_{10}$ standard is weakest. Furthermore the equivalent levels of 8-hr $O_3$ standards in the U.S.A. and the EU were respectively estimated as 97.5 and 95.7 percentiles of the Korean standard with maintaining the existing standard of 60 ppb.