• 제목/요약/키워드: criteria for measurement

검색결과 905건 처리시간 0.029초

Measurement result of ultra wideband corrugated horn for combined ALMA band 7 and band 8 frequencies

  • Lee, Bangwon;Lee, Jung-won;Kang, Hyunwoo;Je, Do-Heung
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.49.4-49.4
    • /
    • 2018
  • We present measurement results of the fabricated ultra wideband corrugated horn for the planned ASTE band7+8 receiver. Return loss and vector beam pattern measurements were carried out over 275-500 GHz frequency range. Hardware set-ups for these measurements are described as well as beam measurement data are compared with such design criteria as beam width, phase curvature and cross-polarization. We discuss the impact of these beam measurement results to the aperture efficiency of the proposed 2-mirror receiver optics for the ASTE telescope.

  • PDF

국내 한의임상연구에서의 어깨질환 환자의 통증 및 기능측정도구 사용에 대한 현황분석 (A Review of the Pain and Function Assessment Instruments for Shoulder Disease Patients in Korean Medicine Clinical Studies Published in South Korea)

  • 이건영;조희근;설재욱;김신애
    • 한방재활의학과학회지
    • /
    • 제28권1호
    • /
    • pp.33-51
    • /
    • 2018
  • Objectives The purpose of this study is to analyze the current status of measurement instruments used to evaluate pain and function for shoulder disease patients in Korean Medicine clinical studies published in South Korea. Methods 5 Korean online databases from January 2007 to July 2017 were used to source articles for the review. Data of pain and function assessment instruments, measurement methods, time point and frequency for shoulder assessment were extracted. And it was analyzed by investigating the frequency of use for each item. Results A total of 78 studies met the selection criteria. There were many studies with no description for pain assessment instruments or inconsistent measurement methods. In the function assessment, the frequency of use was low and there were a lot of use of instruments with low validity and reliability. Conclusions To develop the objectivity of clinical research, further clinical studies, active use of measurement instruments, and standardization of measurement methods are needed.

COTS Component Quality Evaluation Using AHP

  • Oh Kie Sung
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.712-716
    • /
    • 2004
  • Because of rapid development of software technology, a number of software professionals have been concerned with component-based development methodologies. Up to date, the evaluation of component quality has been focused on object-oriented metric based methodology. But this paper presents the selection process and evaluation criteria based on an MCDM(Multiple Criteria Decision Making) technique for the selection of optimal COTS component from consumers' viewpoints. We considered functionality, efficiency and usability based on ISO/IEC 9126 for quality measurement and conducted practical analysis into commercial EJB component in internet. This paper shows that the proposed selection technique is applicable for the selection of the optimal COTS component.

  • PDF

손 치수 측정을 위한 3차원 반자동 측정 방법 개발 (Development of a 3D Semi-Automatic Measurement Protocol for Hand Anthropometric Measurement)

  • 이원섭;윤성혜;유희천
    • 산업공학
    • /
    • 제24권2호
    • /
    • pp.105-111
    • /
    • 2011
  • Measurement protocols for hand anthropometry have been studied for ergonomic product design. The present study developed a 3D semi-automatic measurement protocol (3D-SAMP) which semi-automatically measures various hand dimensions using a 3D scanner. The 3D-SAMP was compared with the conventional direct measurement method (DMM) to examine its effectiveness. The 3D-SAMP consists of (1) fabricating a plaster cast of the hand, (2) placing landmarks on the plaster hand, (3) scanning the plaster hand with a 3D scanner, (4) identifying automatically the positions of the landmarks on the digital hand, and (5) extracting automatically hand anthropometric measurements (lengths, widths, thicknesses, and circumferences). An evaluation experiment conducted in the study found the 3D-SAMP preferred to the DMM in terms of reliability (the number of dimensions exceeding the variability criteria SD=2 mm and CV=5% : 3D-SAMP =2 and DMM=24) and ease of measurement (3D-SAMP=5.2 and DMM=4.3 out of 7). The 3D-SAMP can be applied to ergonomic design of a hand-held product.

선박 방사소음의 측정방법 및 정확도 해석 (Ship Radiated Noise Measurement Methods and Accuracy Analysis)

  • 이필호;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

A QUALITATIVE SURVEY ON SUCCESS FOR MAINTENANCE PROJECTS

  • Albert P C Chan;Daniel W M Chan;Edmond W M Lam
    • 국제학술발표논문집
    • /
    • The 2th International Conference on Construction Engineering and Project Management
    • /
    • pp.186-195
    • /
    • 2007
  • Key Performance Indicators (KPIs) are the criteria of measuring project performance in order to attain construction excellence. Previous researchers have examined the abstract concept of success for general new construction and identified its relationship with the factors of success. In fact, most buildings exist to satisfy the needs of people. With the passing of time and change in technology, buildings have to be maintained and renovated in order to continue functioning properly for the benefits of users. Therefore, criteria and factors of success have increasingly attracted the attention of both researchers and practitioners, especially in cities where buildings become ageing. However, the topic of project success for maintenance projects is less discussed in previous research, and project participants, including maintenance surveyors should be able to identify the success measurement and its associated factors for performance improvement. This study fills the research gap by investigating the criteria and factors of success for maintenance projects. It first provides a summary of the literature review on the criteria and factors of success for construction projects. An empirical study has also been carried out with ten practitioners in Hong Kong to further identify the criteria and factors critical for the success of maintenance projects in practice. While most criteria and factors of success for new construction projects are also applicable to maintenance projects, participants in maintenance projects believe that effective communication is in particular important to provide quality service to the end-users.

  • PDF

Bayesian smoothing under structural measurement error model with multiple covariates

  • Hwang, Jinseub;Kim, Dal Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권3호
    • /
    • pp.709-720
    • /
    • 2017
  • In healthcare and medical research, many important variables have a measurement error such as body mass index and laboratory data. It is also not easy to collect samples of large size because of high cost and long time required to collect the target patient satisfied with inclusion and exclusion criteria. Beside, the demand for solving a complex scientific problem has highly increased so that a semiparametric regression approach could be of substantial value solving this problem. To address the issues of measurement error, small domain and a scientific complexity, we conduct a multivariable Bayesian smoothing under structural measurement error covariate in this article. Specifically we enhance our previous model by incorporating other useful auxiliary covariates free of measurement error. For the regression spline, we use a radial basis functions with fixed knots for the measurement error covariate. We organize a fully Bayesian approach to fit the model and estimate parameters using Markov chain Monte Carlo. Simulation results represent that the method performs well. We illustrate the results using a national survey data for application.

대형공사의 최적입찰자 선정을 위한 계층분석과정(AHP) 모형의 개발 (Development of an Analytic Hierarchy Process Model for the Bidder Selection of a Large Construction Project)

  • 정병호;조권익
    • 경영과학
    • /
    • 제16권1호
    • /
    • pp.75-85
    • /
    • 1999
  • In recent, an unfaithful construction bring about many social problems. The bidding process considering bidding price firstly is one of the reasons raising an unfaithfull construction work. Thus, we should consider many other criteria including bidding price in the bidder selection process. This paper suggests an analytic hierarchy process(AHP) model for selecting the best bidder of a large construction project. A questionnaire was used to obtain domain experts' opinion about criteria to be considered in the bidding process. A hierarchical structure of the AHP model is formed using criteria obtained in the survey. The model consists of bidding price, construction capability, financial status, faith, and their 17 sub-attributes. The relative importance of bidders are judged by pairwise comparison or absolute measurement. An illustrative example is given to show the process selecting the best bidder using the suggested AHP model.

  • PDF

진도율 산정을 위한 측정 단위 도출 방안에 관한 연구 (A General ion Method of Measurement Units for Performance Tracking)

  • 윤수원;진상윤;김예상;정영수;박성수;박순찬
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.521-524
    • /
    • 2003
  • 최근 현장에서는 공사관리의 효율화를 위한 여러 가지 공사관리 시스템을 적용하고 있으며, 이를 통하여 현장의 실적자료를 수집하고 있다. 하지만 이러한 노력에도 불구하고 실적자료의 바탕이 되는 현장 데이터는 객관적 수집 또는 기준에 의해서 이루어지는 것이 아니라 주관적 판단 또는 측정자별로 상이한 기준에 의해 이루어져 각 현장별로 큰 차이가 발생하고 있다. 이러한 문제를 해결하고자 최근 모바일 기술의 발전을 활용한 현장의 데이터 수집을 위한 여러 가지 방안이 연구되고 있으며, 데이터의 체계화에 대한 필요성이 제기되고 있다. 따라서 본 연구는 공종별 특성에 따른 진도 측정 단위 도출 방안을 제안하고, MS Access를 활용한 Prototype의 진도 측정단위 생성 시스템을 개발하였다. 마지막으로, 제안된 도출 방안과 시스템 및 체계는 측정된 데이터의 객관성 및 정확성을 높임으로서, 현장별로 표준화된 진도측정을 가능하게 할 것이다.

  • PDF

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • 대한인간공학회지
    • /
    • 제34권1호
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.