• Title/Summary/Keyword: criteria for analyzing

Search Result 831, Processing Time 0.025 seconds

Verifying the Suitability or Unsuitability of the Opening Force Criteria Applied to Air Pressurized Access Door to a Smoke Control Zone (급기 가압 제연구역 출입문에 적용되는 개방력 기준의 적합성 여부에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5820-5825
    • /
    • 2014
  • The aim of this study was to verify the suitability or unsuitability of Korean body types by measuring the opening force criteria of an air pressurized access door to a smoke control zone. The opening force criteria were verified by comparing the NFSC 501A, NFPA 92A and BS-EN 12101-6 based on the body standards information from the Korean Agency for Technology and Standards. When measuring the opening forces, the posture of the body should be standing upright and pushing an access door with the right hand, which is a criterion for designing doors. As a result of analyzing the actual measurement results, the pushing force of men and women in their 30's was the maximum value and the forces in those in their 60's was the minimum value. In addition, the deviations in the pushing forces varied considerably. As a result of comparing the NFSC 501A, the men showed lower values than the criteria in every gender and age variable except for the 20's, 30's and 50's variable. A comparison of the criteria of NFPA 92A showed that the mean of the measured values from every gender and age was also lower than the criteria. In addition, when comparing the criteria of BS-EN 12101-6, it was found that the men in every age variable were higher than the criteria. On the other hand, the women in every age variable were lower than the criteria. Therefore, considering the Korean body type against the Western body type, it was decided that the opening force of an access door to a smoke control area to make a downward adjustment should be 110 N in the local criteria. Furthermore, the criteria should consider the characteristics of buildings and users because an optional application of the international standard is not necessarily suitable for local situations.

Quantitative Evaluation Index Derivation of the Software Based on ISO/IEC 9126-2 Metrics (ISO/IEC 9126-2 메트릭을 활용한 소프트웨어 정량적 평가 지표 도출)

  • Cho, Sungho;Jang, Joongsoon
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.134-146
    • /
    • 2016
  • Purpose: Many domestic companies have to make out quantitative evaluation table in their proposal when they conduct the software R&D project. However, most of companies have a difficulty to select the evaluation items and criteria, also to derive a quantitative results. Therefore, we propose a method to derive the quantitative evaluation index by utilizing the ISO/IEC 9126-2. Methods: Analyzing ISO/IEC 9126-2, and we classify the quality metrics as high-classification and sub-classification for Web/App software, Embedded software and Installation software. Next, Conduct the metrics selection survey depending on importance and necessity. Then, carry out the case study. Verify the correspondence between evaluation items and criteria from original suggestion of company and from outcome by utilizing the ISO/IEC 9126-2 quality metrics. Results: It is possible to classify into two metrics, one for common software or one another for only special software. Furthermore, there is quality metrics that is more important and more necessary depending upon characteristics of the software. Conclusion: ISO/IEC 9126-2 quality metrics can be used to make an evaluation items and criteria for quantitative evaluation table of software product.

An Application of the NPR Process for the Treatability Improvement of an Existing Sewage Treatment Plant (기존 하수처리장 성능개선을 위한 NPR공정의 적용)

  • Moon, Tae Hoon;Ko, Kwang Baik;Song, Eui Yeol
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.756-760
    • /
    • 2007
  • Most of the sewage treatment plants in Korea are being operated by using the conventional activated sludge process. Recently, as the water criteria have been strict with regard to such main culprits of eutrophication, the existing sewage treatment plants are obliged to upgrade their treatment technology to meet the criteria. Under such circumstances, this study was aimed at analyzing the conditions of an existing sewage treatment plants in Korea, and thereupon, test its treatment performance for the actual sewage water by operating a pilot plant. When the pilot plant was operated with the NPR process at the capacity of $30m^3/day$, the average contents of BOD, $COD_{Mn}$, SS, T-N and T-P in the effluents were 7.0 mg/L, 9.7 mg/L, 5.1 mg/L, 8.0 mg/L and 0.23 mg/L, respectively, which were very stable in general. Accordingly, if the NPR process used for this pilot plant to upgrade the treatment technology for the sewage treatment plat could be adopted, the effluent water quality criteria effective beginning from 2008 would be met.

Development of a Technical Road Map for Future Research in Wind Power Generation using Grading Criteria as a Rubric for Research Focus (풍력 발전에서 미래 연구를 위한 연구 집중으로서 등급 기준을 이용한 기술 로드맵 개발)

  • Park, Jong-Kyu;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.3
    • /
    • pp.417-423
    • /
    • 2011
  • Generally, in order to avoid overlap with previous research and to initiate the innovative research, researchers must analyze patent information before research can begin. In this paper, the development of grading criteria using current trends in the wind power generation will be performed by analyzing the following criteria: technology position of major countries, impact factor each countries, patent family size, patent portfolios analysis, patent applied analysis, and analysis of nationality for a patent. This patent information for the wind power generation is expected to be useful in deciding the direction of future research.

BIM Model Quality Improvement by Case Study Analysis (품질검증 사례 분석을 통한 BIM모델 품질개선 방안)

  • Kwon, O-Cheol;Cho, Joo-Won;Jo, Chan-Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.164-174
    • /
    • 2012
  • The recent introduction of BIM technology has raised the interest on the BIM quality assurance and management more than ever. This study aims to consider the ways of BIM quality improvement by analyzing the most frequent issues rising from multiple BIM projects. For this purpose, the 12 test models from BIM education program hosted by buildingSMART Korea are investigated based on the requirements in the public BIM guidelines. All the BIM issues generated are categorized by the criteria applied and analyzed for each kind of building element. The results showed that more than half of the issued at least could be cleared out by improving modeling habits and technical guides.

Heuristic Composite Web Service Execution Planning Algorithm Based on Quality of Service Criteria (웹 서비스 품질 지표 기반 컴포지트 웹 서비스 실행 계획 알고리즘)

  • Ko, Jong-Myung;Kim, Chang-Ouk
    • IE interfaces
    • /
    • v.19 no.3
    • /
    • pp.190-201
    • /
    • 2006
  • With the rapid growth in the demand and supply of web service, the search for superior services has become a prominent issue. Furthermore, much emphasis and attention are being placed on composite web services, where individual services are combined together to form a single workflow to satisfy the demand of the customers. In today's era of excessive expansion of web services, this study intends to propose the execution plan architecture for composite web services to accomplish the following three goals. The first goal is to derive a feasible plan which maximize user satisfaction for composite web services by implementing an execution plan architecture that reflects the Quality of Service criteria. Secondly, this study also aims at analyzing and selecting the indexes that adequately reflects its quality and its nonfunctional property. Finally, this study intends to apply the concept of constraint satisfaction problem and heuristics to reduce the execution duration of the process.

Effective Data Management Method for Operational Data on Accredited Engineering Programs (공학교육인증 프로그램의 효과적인 운영 데이터 관리 방법)

  • Han, Kyoung-Soo
    • Journal of Engineering Education Research
    • /
    • v.17 no.5
    • /
    • pp.51-58
    • /
    • 2014
  • This study proposes an effective data management method for easing the burden on self-study report by analyzing operational data on accredited engineering programs. Four analysis criteria are developed: variability, difficulty level of collecting, urgency of analysis, timeliness. After the operational data are analyzed in terms of the analysis criteria, the data which should be managed in time are extracted according to the analysis results. This study proposes a data management method in which tasks of managing the timely-managed data are performed based on the regular academic schedule, so that the result of this study may be used as a working-level reference material.

Analysis of MBLOCA and LBLOCA success criteria in VVER-1000/V320 reactors: New proposals for PSA Level 1

  • Elena Redondo-Valero;Cesar Queral;Kevin Fernandez-Cosials;Victor Hugo Sanchez-Espinoza
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.623-639
    • /
    • 2023
  • The specific configuration of the safety systems in VVER-1000/V320 reactors allows a comprehensive study of the Loss of Coolant Accident (LOCA). In the present paper, a verification of the success criteria of the event trees headers for the medium and large break LOCA sequences is conducted. A detailed TRACEV5P5 thermal-hydraulic model of the reactor has been developed, including all safety systems. When analyzing the results of all sequences, some conservatism is observed in certain specific configurations as the success criterion of some headers is not consistent with the classic PSA level 1. Therefore, new proposals for the LOCA event trees are performed based on a reconfiguration of LOCA break ranges and the use of the expanded event trees approach.

An Amendment of the VLF tanδ Criteria to Improve the Diagnostic Accuracy of the XLPE-insulated Power Cables (XLPE 절연케이블의 열화진단 정확도 향상을 위한 VLF tanδ 판정기준 개선)

  • Lee, Jae-Bong;Jung, Yeon-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1644-1651
    • /
    • 2010
  • VLF $tan{\delta}$ diagnosis technology is introduced in IEEE Std 400 and proposed as evaluation criterion in an effective way of detecting water tree which mainly causes the failure of XLPE insulated cables. In order to inspect the accuracy of the VLF $tan{\delta}$ method for XLPE insulated power cables in Korean distribution system, diagnosis for 41 cables which were being serviced in the fields has been carried out and they were removed for AC breakdown voltage test after. Regarding the 41 cables, it was hard to confirm any relation between the VLF $tan{\delta}$ values and AC breakdown voltages and also water tree in the insulation was not detected. However, the other cables were failed several days after the diagnosis of the 41 cables. Water trees were found and their VLF $tan{\delta}$ values were also much higher than the criterion of IEEE standard. It has been ascertained that we need to change the IEEE criteria in order to improve the accuracy of detecting water trees by additional analyzing of field examples of failure and case studies from overseas countries and therefore amended VLF $tan{\delta}$ test voltage and evaluation criteria have been proposed.

The Environmental Analyzing Method of Mixed Coal Ash in Ash Pond to Recycle as a Construction Material (건설재료로 재활용하는 회사장 혼합석탄재의 환경적 검토 방법)

  • Koh, Yong-Il
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.12
    • /
    • pp.75-79
    • /
    • 2012
  • In the recycling of industrial waste unlike household waste, the legislation and the governmental systematic support, etc. were not also established due to an anxiety of hazard or harmfulness, etc. and a preconception. So the legislation and the system should be urgently established for the recycling of industrial waste. In this study, the environmental analyzing method of industrial waste-mixed coal ash in ash pond to recycle as a construction material is suggested by considering and analyzing test process and results about environmental impact factors of mixed coal ash. It is certified that there are not environmental problems in the recycling of mixed coal ash in ash pond as a construction material, according as its classification is general waste and each corresponding item of the leaching test result are satisfied with the 'environmental safety criteria' suggested in this study. And to build database, it is necessary to survey the environmental impact on surrounding areas with time after its recycling as a construction material.