• Title/Summary/Keyword: crest width

Search Result 86, Processing Time 0.024 seconds

Experimental Study on Wave Transmission Coefficients of Submerged Structure : II. Rubble-Mound Type Structure armored by Tetrapods (수중구조물의 파고전달계수 산정 실험 : II. 테트라포드 피복 경사형 수중구조물)

  • Lee, Jong-In;Kim, Young Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.497-507
    • /
    • 2020
  • Two-dimensional laboratory experiments were conducted in a wave flume to investigate the wave transmission phenomena of rubble-mound type submerged structures armored with Tetrapods. Different experimental conditions were included by considering relative crest depth, relative freeboard, relative crest width, wave steepness, and so on. An empirical formula was proposed to predict the wave transmission coefficients over various specifications and structural designs of the partial perforated (rubble-mound) type submerged structure from the experimental results. The proposed formula successfully predicted the wave transmission coefficients. In this study, the proposed empirical formula of the wave transmission over the rubble-mound type submerged structure was improved from the existing formula.

Study on the frequency of self-excited pulse jet

  • Wang, Jian;Li, Jiangyun;Guan, Kai;Ma, Tianyou
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.4
    • /
    • pp.206-212
    • /
    • 2013
  • Self-excited pulse jet is a specific nozzle with a closed chamber which can change a continuous jet into a pulse one. Energy of the pulse jet can be output not only unevenly but also with multifrequency. With the peak pressure of pulse jet, the hitting power would be 2~2.5 times higher than that of continuous jet. In order to reveal the correlation between the self-excited pulse frequency and nozzle diameter ratio, nozzle spacing and operating pressure, the model of 3D unsteady cavitation model has been used. We found that with the same nozzle structure parameters and the different operating pressure, the self-excited frequency and the width of peak crest are different, but the wave profiles are similar. With FFT, we also found that the less bandwidth of amplitude in low frequency range will lead to the wider wave crest of outlet velocity in its time domain, and the larger force of the strike will be gained. By studying the St of self-excite nozzle, not only the frequency of a certain nozzle can be predicted, but also a nozzle structure with a certain frequency can be designed.

Experimental Study on Wave Transmission Coefficients of Submerged Structures: III. Impermeable-Type Structure (수중구조물의 파고전달계수 산정 실험 : III. 불투과형 수중구조물)

  • Lee, Jong-In;Cho, Ji Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.593-601
    • /
    • 2020
  • Two-dimensional laboratory experiments were conducted in a wave flume to investigate the wave transmission phenomena of impermeable-type submerged structures armored by concrete blocks. Different experimental conditions were included by considering relative crest depth, relative freeboard, relative crest width, wave steepness, and so on. An empirical formula was proposed to predict the wave transmission coefficients over various specifications and structural designs of the impermeable submerged structure from the experimental results. The proposed formula successfully predicted the wave transmission coefficients. Therefore, in this study, the proposed empirical formula of the wave transmission over an impermeable submerged structure was improved from the existing formula.

Clinical evaluation of a collagen matrix to enhance the width of keratinized gingiva around dental implants

  • Lee, Kang-Ho;Kim, Byung-Ock;Jang, Hyun-Seon
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.96-101
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of collagen matrix with apically positioned flap (APF) on the width of keratinized gingiva, comparing to the results of APF only and APF combined with free gingival graft (FGG) at the second implant surgery. Methods: Nine patients were selected from those who had received treatments at the Department of Periodontics, Chosun University Dental Hospital, Gwangju, Korea. We performed APF, APF combined with FGG, and APF combined with collagen matrix coverage respectively. Clinical evaluation of keratinized gingival was performed by measuring the distance from the gingival crest to the mucogingival junction at the mid-buccal point, using a periodontal probe before and after the surgery. Results: The ratio of an increase was 0.3, 0.6, and 0.6 for the three subjects in the APF cases, 3, 5, and 7 for the three in the APF combined with FGG case, and 1.5, 0.5, and 3 for the three in the APF combined with collagen matrix coverage case. Conclusions: This study suggests that the collagen matrix when used as a soft tissue substitute with the aim of increasing the width of keratinized tissue or mucosa, was as effective and predictable as the FGG.

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

The effect of different radiographic parameters on the height, width and visibility of cross-sectional image of mandible in spiral tomography (나선형 단층방사선사진촬영에서 촬영조건이 악골 단면상의 높이, 폭 및 인지도에 미치는 영향)

  • Lee Tae-Wan;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-49
    • /
    • 2003
  • Purpose : To evaluate the differences in bone height, bone width, and visibility of posterior spiral tomographic images according to various exposure directions, image layer thickness, and inclination of the mandibular inferior border. Materials and Methods: Six partially and completely edentulous dry mandibles were radiographed using Scanora spiral tomography. Spiral tomography was performed at different exposure directions (dentotangential and maxillotangential projection), image layer thicknesses (2 mm, 4 mm and 8 mm), and at various inclinations to the mandibular border (+ 100, 00 and -10°). The bone height and width was measured using selected tomographic images. The visibility of mandibular canal, crestal bone, and buccal and lingual surfaces were graded as 0, 1, or 2. Results : The bone width at the maxillo-tangential projection was wider than at the dento-tangential projection (p < 0.05). The visibility of buccal and lingual surface at the maxillo-tangential projection was higher than at the dento-tangential projection (p<0.05). Thinner image layer thicknesses resulted in greater visibility of buccal and lingual surfaces (p < 0.05). Bone height was greatest in the -10° group, and at the same time the bone width of the same group was the narrowest (p < 0.05). The visibility of alveolar crest and buccal surface of the + 10° group was the highest, while the visibility of the mandibular canal was greatest in the 00 group. Conclusion: When spiral tomography is performed at the mandibular posterior portion for visualization prior to implant surgery, it is important that the inferior border of mandible be positioned as parallel as possible to the floor. A greater improvement of visibility can be achieved by maintaining a thin image layer thickness when performing spiral tomography.

  • PDF

A HISTOLOGIC STUDY OF INITIAL CHANCE AND REPAIR OF TOOTH AND PERIODONTAL TISSUE IN EXTRUSION OF YOUNG ADULT DOGS (유성견 소구치 정출시 치아 및 치주 조직의 초기 조직학적 변화 및 재생에 관한 연구)

  • Yoon, Byung-sun;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.419-429
    • /
    • 1998
  • This study was carried out in order to study early histologic changes and repair reaction appling to extrusive force for 3rd premolar of adult dogs. After 1 week of extrusive force with elastic chain, one of dogs was sacrified and after 3 weeks retention period, another dog was sacrified. The paraffin sections of samples were stained with Hematoxylin - Eosin and Masson's Trichrome and were examed by light microscopy . The obtained results as follows 1. In Hematoxylin - Eosin and Masson Trichrome stain of control group , the periodontal ligament width was constant from apical third to cervical third of the root and periodontal fiber arrangement was horizontal or oblique in cervical third. oblique in middle third, oblique in apical third of root. in alveolar bone, smooth appearance was shown 2. In Group 1, all periodontal fiber arrangement was oblique toward tooth, and the periodontal ligament width increased Partially PDL was ruptured in apex. In MT stain, immature bone formation was seen at alveolar crest area. Active bone formation was observed along the one side of alveolus, and apical portion of pulp was involved with blood vessel rupture , vacuolization of pulp tissue and hyperemia 3. In Group 2, most periodontal ligament arrangement and PDL width was repaired and fiber density increased. In MT stain, mineralization of immature bone on the alveolar crest was progressed. In pulp, vacuole and hyperemia was diminished and fibrotic change was diminished 4. After 3 week periodontal ligament has more repair ability than pulp tissue. pulp was involved with vacuolization and fibrosis, so it takes more time for repair.

  • PDF

A Study on Reduction of Torque Pulsating for BLDCM Using CDTP Control Method (CDTP 기법을 이용한 BLDC 전동기의 토크맥동 저감에 관한 연구)

  • Kang, Byoung-Hee;Shin, Woo-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.113-119
    • /
    • 2006
  • This paper studies the torque characteristics of CDTP controlled BLDCM with various back-EMF waveforms. We propose a CDTP method to suppress torque pulsation due to commutation time and point. It is adopted to control the BLDCM with real back-EMF waveforms through the Hague's method for minimizing torque ripple. Real back-EMF waveforms are produced with a magnetic fringing factor and crest width of back-EMF. The performance and characteristics of the proposed control method are analyzed by simulation and verified through experimental results.

RIGID FIXATION AND SPACE MAINTENANCE BY TITANIUM MESH FOR RECONSTRUCTION OF THE PREMAXILLA (상악골 전방 결손부 재건 시 견고 고정과 공간 유지로 사용된 타이타니움 메쉬의 임상 예)

  • Lee, Eun-Young;Kim, Kyoung-Won;Choi, Hee-Won;Koh, Myoung-Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.1
    • /
    • pp.85-92
    • /
    • 2005
  • Reconstruction of defect in the anterior part of the maxilla to enable implant placement or prothesis is a complicated treatment due to the anatomical position and lack of soft tissues. Two cases are presented in which autogenous iliac PMCB(particulate marrow and cancellous bone) with titanium mesh were used for premaxilla reconstruction and alveolar bone repair of the anterior maxillas prior to denture and implants fixation respectively. Cancellous bone from the anterior iliac crest was compressed and placed against a titanium mesh fixed to the bone of palate in a patient with severe defect of the anterior maxilla. There were no problem in the healing, and the anterior maxillas of two patients had increased height and width during the initial healing and remodeling. The clinical reports describe the use of titanium mesh for reconstruction of premaxilla. Autogenous bone grafts were harvested from the iliac crest and were loaded on a titanium mesh that were left in the patient's maxilla for 6 months before they were removed respectively. The radiographic analysis demonstrated that a 10mm vertical ridge augmentation had been achieved. In guided bone regeneration, the quantity of bone regenerated under the barrier has been demonstrated to be directly related to the amount of the space under the membrane. This space can diminish as a result of membrane collapse. To avoid this problem which involved the use of a titanium mesh barrier to protect the regenerating tissues and to achieve a rigid fixation of the bone segments, were used in association with autologous bone in 2 cases. The aim of this study was to evaluate the capability of a configured titanium mesh to serve as a mechanical and biologic device for restoring a vertically defected premaxilla.

Evaluation of Correlation between Earthquake Induced Settlement of Fill Dams and Ground Motion Parameters (지진 시 필댐의 침하량과 지반진동 변수 간의 상관관계 분석)

  • Baeg, Jongmin;Park, Duhee;Yoon, Jinam;Choi, Byoung-Han
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.65-72
    • /
    • 2018
  • Seismically induced settlement exceeding dam freeboard may lead to a dam failure. The prediction of settlement is important also because it is also reported to be strongly related to longitudinal crack width and depth, which are critical indices used for safe evaluation of dams. The empirical correlation derived from numerical simulations is most often used. In this study, two-dimensional dynamic nonlinear analyses are performed using representative CFRD and ECRD fill dams. A total of 20 recorded motions are used to account for the influence on ground motion intensity and magnitude. The calculated crest settlements are correlated to four ground motion parameters, which are peak ground acceleration (PGA), peak ground velocity (PGV), Aria Intensity ($I_A$), and magnitude. It is demonstrated that using ground motion parameters in addition to PGA can significantly increase the prediction accuracy.