• 제목/요약/키워드: crest angle

검색결과 67건 처리시간 0.028초

Comparison of Femoral Anteversion Angle and Determination of Reliability Measured at Three Different Anatomical References of the Tibial Crest During the Trochanteric Prominence Angle Test

  • Lee, Ji-Hyun;Yoon, Tae-Lim;Choi, Sil-Ah;Cynn, Heon-Seock
    • 한국전문물리치료학회지
    • /
    • 제19권4호
    • /
    • pp.55-60
    • /
    • 2012
  • The trochanteric prominence angle test (TPAT) has been used to measure the femoral anteversion angle between the tibial crest and the vertical line. However, the exact anatomical reference of the tibial crest has not yet been identified in the literature. Thus, the purposes of this research were twofold: first, to compare the femoral anteversion angle measured at three different anatomical references of the tibial crest (the proximal tibial crest, the proximal third of tibial crest, and the proximal half of tibial crest) and, second, to determine inter-and intra-rater reliabilities of the femoral anteversion angle measured at these three different anatomical references of the tibial crest during the TPAT. We recruited 14 healthy subjects, and a total of 28 legs were examined. The TPAT was measured using a digital inclinometer. A 1-way repeated-measure analysis of variance was used to compare the femoral anteversion angle measured at three different anatomical references of the tibial crest, and intraclass correlation coefficients (ICCs) were calculated to determine reliability. The femoral anteversion angle measured at the proximal tibial crest was significantly higher than that at the proximal third of the tibial crest and the proximal half of the tibial crest. The inter-and intra-rater reliabilities of femoral anteversion angle were measured at three anatomic references of the tibial crest were all found to be high during the TPAT (ICC=.9 0~.98). In conclusion, clinicians should recognize that the different degrees of the femoral anteversion angle could be measured when different anatomical references of the tibial crest were used, and that reliabilities were high when an exact anatomical reference of the tibial crest was used during the TPAT.

습관적인 편측지지가 요통환자의 측만각과 장골능 높이에 미치는 영향 (Influence of Habitual Unilateral Support on Scoliosis Angle and Iliac Crest Height of Lumbago Patients)

  • 조운수;김용남;정진규
    • 대한임상전기생리학회지
    • /
    • 제5권2호
    • /
    • pp.73-84
    • /
    • 2007
  • This study aims to examine changes from differences in the lumbar scoliosis angle and iliac crest height due to abnormal and habitual posture shown in unilateral weight load at standing posture and suggest data for preventing and treating lumbago. The subjects of this study are 16 lumbago patients between twenties and forties with chronic lumbago over six months, but without neurological symptoms. As a result of photographing front and back with three conditions such as weight load on both sides and left or right unilateral weight load posture in order to examine changes of lumbar scoliosis and iliac crest according to changes of posture at unilateral weight load, while scoliosis angle and iliac crest height by habitual unilateral support were increased, those by opposite support were decreased. In conclusion, it was found that habitual unilateral weight load may cause continuous distortion of spinal angle and change of iliac crest height and these may be a factor of lumbago. Therefore, if habitual unilateral weight load state is kept continuously, distortion of lumbar angle and iliac crest height may be greater and common efforts to change habitual unilateral weight load are needed.

  • PDF

Factors Affecting Cage Obliquity and the Relationship between Cage Obliquity and Radiological Outcomes in Oblique Lateral Interbody Fusion at the L4-L5 Level

  • CheolWon Jang;SungHwan Hwang;Tae Kyung Jin;Hyung Jin Shin;Byung-Kyu Cho
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권6호
    • /
    • pp.703-715
    • /
    • 2023
  • Objective : This retrospective study investigated the factors that affect cage obliquity angle despite orthogonal maneuvers performed during oblique lateral interbody fusion (OLIF) and assessed the relationship between cage obliquity angle and radiological outcomes post-surgery. Methods : Twenty-nine males who underwent L4-L5 OLIF for lumbar degenerative disease between 2019 and 2021 with a followup duration greater than 12 months were analyzed. Radiological parameters were measured including psoas muscle volume, total psoas area index (total psoas muscle area [cm2]/height squared [m2]), distance from the iliac artery to the origin of the psoas muscle (DIAPM), angle between the origin of the psoas muscle and the center of the vertebral disc (APCVD), iliac crest height, disc height, lumbar flexibility (lumbar flexion angle minus extension angle), cage location ratio, cage-induced segmental lumbar lordosis (LL) (postoperative index level segmental LL minus used cage angle), foraminal height changes, fusion grade. Results : DIAPM, APCVD, iliac crest height, postoperative index level segmental LL, and cage-induced segmental LL were significantly correlated with OLIF cage obliquity angle. However, other radiological parameters did not correlate with cage obliquity. Based on multiple regression analysis, the predictive equation for the OLIF cage obliquity angle was 13.062-0.318×DIAPM+0.325×1APCVD+0.174×iliac crest height. The greater the cage obliquity, the smaller the segmental LL compared to the cage angle used. Conclusion : At the L4-L5 level, OLIF cage obliquity was affected by DIAPM, APCVD, and iliac crest height, and as the cage obliquity angle increases, LL agnle achievable by the used cage could not be obtained.

임플랜트와 경부골이 이루는 각도가 치경부 응력 발생에 미치는 영향 (AN EVALUATION OF ANGLES BETWEEN THE ALVEOLAR CREST BONE AND THE IMPLANT EFFECT ON THE IMPLANT CRESTAL AREA INDUCED STRESSES USING A FINITE ELEMENT METHOD)

  • 조성범;이규복;조광헌
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.274-282
    • /
    • 2007
  • Statement of problem: Main consideration was given to the stresses at the site of implant entry into the cortical bone at the alveolar crest. As a suspectible factor affecting the occurrence of stress concentrations, the contact angle between the implant and the alveolar crest bone was addressed. Purpose: The purpose of this study is to evaluate angles between the alveolar crest bone and the implant effect on the implant crestal area induced stresses using a finite element method. Material and methods: Cylindrically shaped, standard size ITI implants entering into alveolar crest with four different contact angles of 0, 15, 30, and 45 deg. with the long axis of the implant were axisymmetrically modelled. Alterations of stresses around the implants were computed and compared at the cervical cortical bone. Results and conclusion: The results demonstrated that regardless of the difference of the implant/alveolar crest bone contact angles, stress concentration occurred at the cervical bone and the angle differences led to insignificant variations in stress level.

지진하중을 받는 필댐 정부변위에 영향을 미치는 입력물성에 대한 민감도 분석 (Sensitivity Analysis of Rockfill Parameters Influencing Crest Displacements of CFRD Subjected to Earthquake Loading)

  • 하익수;신동훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.351-357
    • /
    • 2006
  • In this study, quantitative sensitivity analysis on rockfill material influencing the dam crest displacement of Concrete-Faced Rockfill Dam(CFRD) subjected to earthquake loading was carried out. The purpose of this study is to indicate the most important input parameter and to show the quantitative variation of displacement at the crest of CFR type dam during earthquake loading with this input parameter. From the sensitivity analysis, it was found that the crest displacement of CFR type dam subjected to dynamic loading was absolutely affected by the shear modulus of rockfill material and the effect of friction angle of it was negligible. This relative difference of sensitivity was more outstanding in case of crest settlement than in case of crest horizontal displacement. Also, it was found that the extent of effect of shear modulus on the displacement at the crest of CFRD due to dynamic loading decreased as maximum amplitude of input acceleration increased.

  • PDF

Uplift capacity of horizontal anchor plate embedded near to the cohesionless slope by limit analysis

  • Bhattacharya, Paramita;Sahoo, Sagarika
    • Geomechanics and Engineering
    • /
    • 제13권4호
    • /
    • pp.701-714
    • /
    • 2017
  • The effect of nearby cohesionless sloping ground on the uplift capacity of horizontal strip plate anchor embedded in sand deposit with horizontal ground surface has been studied numerically. The numerical analysis has been carried out by using the lower bound theorem of limit analysis with finite elements and linear optimization. The results have been presented in the form of non-dimensional uplift capacity factor of anchor plate by changing its distance from the slope crest for different slope angles, embedment ratios and angles of soil internal friction. It has been found that the decrease in horizontal distance between the edge of the anchor plate and the slope crest causes a continuous decrease in uplift capacity of anchor plate. The optimum distance is that distance between slope crest and anchor plate below which uplift capacity of an anchor plate has been found to decrease with a decrease in normalized crest distance from the anchor plate in presence of nearby sloping ground. The normalized optimum distance between the slope crest and the anchor plate has been found to increase with an increase in slope angle, embedment ratio and soil internal friction angle.

Assessment of lower incisor alveolar bone width using cone-beam computed tomography images in skeletal Class III adults of different vertical patterns

  • Lee, Sanghee;Hwang, Soonshin;Jang, Woowon;Choi, Yoon Jeong;Chung, Chooryung J;Kim, Kyung-Ho
    • 대한치과교정학회지
    • /
    • 제48권6호
    • /
    • pp.349-356
    • /
    • 2018
  • Objective: This study was performed to investigate the alveolar bone of lower incisors in skeletal Class III adults of different vertical facial patterns and to compare it with that of Class I adults using cone-beam computed tomography (CBCT) images. Methods: CBCT images of 90 skeletal Class III and 29 Class I patients were evaluated. Class III subjects were divided by mandibular plane angle: high (SN-MP > $38.0^{\circ}$), normal ($30.0^{\circ}$ < SN-MP < $37.0^{\circ}$), and low (SN-MP < $28.0^{\circ}$) groups. Buccolingual alveolar bone thickness was measured using CBCT images of mandibular incisors at alveolar crest and 3, 6, and 9 mm apical levels. Linear mixed model, Bonferroni post-hoc test, and Pearson correlation analysis were used for statistical significance. Results: Buccolingual alveolar bone in Class III high, normal and low angle subjects was not significantly different at alveolar crest and 3 mm apical level while lingual bone was thicker at 6 and 9 mm apical levels than on buccal side. Class III high angle group had thinner alveolar bone at all levels except at buccal alveolar crest and 9 mm apical level on lingual side compared to the Class I group. Class III high angle group showed thinner alveolar bone than the Class III normal or low angle groups in most regions. Mandibular plane angle showed negative correlations with mandibular anterior alveolar bone thickness. Conclusions: Skeletal Class III subjects with high mandibular plane angles showed thinner mandibular alveolar bone in most areas compared to normal or low angle subjects. Mandibular plane angle was negatively correlated with buccolingual alveolar bone thickness.

해안 비디오로부터 관측된 쇄파지역에서 입사각의 변화 (Variation of Incident Wave Angle in the Surf Zone Observed from Digital Videos)

  • 유제선;신동민;조용식
    • 한국해안·해양공학회논문집
    • /
    • 제21권2호
    • /
    • pp.154-163
    • /
    • 2009
  • 해안에서 입사파향은 일반적으로 실측 파랑자료로부터 생성한 파향 스펙트럼 분석을 통하여 구하지만, 파향의 실측기법은 현장 계기설치시 많은 인력과 비용이 소요되기 때문에 전 쇄파지역에 걸쳐 입사파향을 관측하기에는 어려움이 따른다. 이러한 이유로, 본 연구는 해안 디지털 비디오 자료에 나타나는 입사파의 파봉선을 이용하여 쇄파지역에서 입사파의 변화를 관측하는 기술을 제안한다. 파봉선은 이미지 상에서 선인식 기법을 이용하여 이미지 강도가 큰 픽셀들을 추적해 나감으로써 추출한다. 입사파향은 추출된 파봉선의 일차미분값, 즉, 실제 평면좌표 공간에서 파봉선의 기울기를 계산하여 구한다. 비디오 자료로부터 입사파향의 측정결과는 실측 파랑자료의 파향 스펙트럼으로부터 구한 파향 계산결과와 비교적 잘 일치한다.

Lead Screw 전조 정밀도 향상을 위한 성형인자의 특성평가 (Characteristics Evaluation of Process Parameters for Improvement the Precision of Thread ]tolling in Lead Screw)

  • 김광호;김동환;고대철;김병민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.312-315
    • /
    • 2002
  • This paper summarizes the results of a numerical study conducted to analyze the effect of selected process parameters on material flow and thread profile in thread rolling of large diameter blanks. Based on the previous work where a plane strain mode was found to provide a reasonable approximation of the thread rolling process, the effect of varying thread form, friction factor, flow stress, and blank diameter on effective strain and thread height was analyzed using the finite element code DEFORM. This study show that effective strain for flank angle, that blank diameter had important effect on the as-rolled thread while flow stress, friction factor, and crest round of dies had significant impact on effective strain at the thread root and crest and load of thread rolling. While the rate of strain harding was found to have an effect on the crest profile, the results indicate that it is the primary factor responsible for seam formation in rolled threads.

  • PDF

Numerical Study of Inflation of a Dipolar Magnetic Field by Injecting Plasma with Different Beta

  • Kajimura, Yoshihiro;Funaki, Ikkoh;Shinohara, Iku;Usui, Hideyuki;Nakashima, Hideki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.553-556
    • /
    • 2008
  • A Magneto Plasma Sail(MPS) produces propulsive force by the interaction between the solar wind and an artificial magnetic field inflated by injecting plasma. Using a 2D hybrid PIC code, we evaluate the inflation of magnetic field when Argon(Ar) plasma with different ${\beta}_{in}$ including the value less than one is injected into the dipolar magnetic field generated by a superconducting coil. It is found that the magnetic field can be inflated by injecting plasma within an angle of $30^{\circ}$ in the polar direction and the magnetic field decays in the polar direction according to $B{\propto}r^{-2.4}$ after the plasma(${\beta}_{in}$=0.1) is injected.

  • PDF