• Title/Summary/Keyword: cracking damage

Search Result 388, Processing Time 0.021 seconds

Self-healing Coatings for an Anti-corrosion Barrier in Damaged Parts

  • Cho, Soo Hyoun
    • Corrosion Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.223-226
    • /
    • 2009
  • Polymer coatings are commonly applied to metal substrates to prevent corrosion in aggressive environments such as high humidity and under salt water. Once the polymer coating has been breached, for example due to cracking or scratches, it loses its effectiveness, and corrosion can rapidly propagate across the substrate. The self-healing system we will describe prevents corrosion by healing the damage through a healing reaction triggered by the actual damage event. This self-healing coating solution can be easily applied to most substrate materials, and our dual-capsule healing system provides a general approach to be compatible with most common polymer matrices. Specifically, we expect an excellent anti-corrosion property of the self-healing coatings in damaged parts coated on galvanized metal substrates.

Real-time Failure Detection of Composite Structures Using Optical Fiber Sensors (광섬유 센서를 이용한 복합재 구조물의 실시간 파손감지)

  • 방형준;강현규;류치영;김대현;강동훈;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.128-133
    • /
    • 2000
  • The objective of this research is to develop real-time failure detection techniques for damage assessment of composite materials using optical fiber sensors. Signals from matrix cracking or fiber fracture in composite laminates are treated by signal processing unit in real-time. This paper describes the implementation of time-frequency analysis such as the Short Time Fourier Transform(STFT) to determine the time of occurrence of failure. In order to verify the performance of the optical fiber sensor for stress wave detection, we performed pencil break test with EFPI sensor and compared it with that of PZT. The EFPI sensor was embedded in composite beam to sense the failure signals and a tensile test was performed. The signals of the fiber optic sensor when damage occurred were characterized using STFT and wavelet transform. Failure detection system detected the moment of failure accurately and showed good sensitivity with the infinitesimal failure signal.

  • PDF

Ultimate behavior of reinforced concrete cooling tower: Evaluation and comparison of design guidelines

  • Noh, Hyuk-Chun;Choi, Chang-Koon
    • Structural Engineering and Mechanics
    • /
    • v.22 no.2
    • /
    • pp.223-240
    • /
    • 2006
  • Taking into account the geometrical and material nonlinearities, an ultimate behavior of reinforced concrete cooling tower shell in hyperbolic configuration is presented. The design wind pressures suggested in the guidelines of the US (ACI) and Germany (VGB), with or without the effect of internal suction, are employed in the analysis to examine the qualitative and quantitative characteristics of each design wind pressure. The geometrical nonlinearity is incorporated by the Green-Lagrange strain tensor. The nonlinear features of concrete, such as the nonlinear stress-strain relation in compression, the tensile cracking with the smeared crack model, an effect of tension stiffening, are taken into account. The biaxial stress state in concrete is represented by an improved work-hardening plasticity model. From the perspective of quality of wind pressures, the two guidelines are determined as highly correlated each other. Through the extensive analysis on the Niederaussem cooling tower in Germany, not only the ultimate load is determined but also the mechanism of failure, distribution of cracks, damage processes, stress redistributions, and mean crack width are examined.

Assessing Compressive Failure Characteristics of Hybrid Fiber Reinforced Cementitious Composites by Acoustic Emission (AE기법에 의한 하이브리드 섬유보강 시멘트복합체의 압축파괴특성 평가)

  • Kim, Sun-Woo;Ji, Sang-Kyu;Jeon, Su-Man;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.229-232
    • /
    • 2006
  • The HPFRCCs show that the multiple crack propagation, high tensile strength and ductility due to the interfacial bonding of the fibers to the cement matrix. Moreover, performance of cement composites varies according to type and weight contents of reinforcing fiber. and HPFRCCs with hybrid fiber have better performance than HPFRCCs with single fiber in damage tolerance. Total four cylindrical specimens were tested, and the main variables were the type and weight contents of fiber, which was polyvinylalchol (PVA), polyethylene (PE). In order to clarify effect of hybrid types on the characteristics of fracture and damage process in cement composites, AE method was performed to detect micro-cracking in HPFRCCs under cyclic compression. Loading conditions of the uniaxial compression test were monotonic and cyclic loading. And from AE parameter value, it is found that the second and third compressive load cycles resulted in successive decrease of the amplitude as compared with the first compressive load cvcle.

  • PDF

Definition of Digital Twin Models for Prediction of Future Performance of Bridges (교량의 장기성능 예측을 위한 디지털 트윈모델 정의)

  • Shim, Chang-Su;Jeon, Chi Ho;Kang, Hwi Rang;Dang, Ngoc Son;Lon, Sokanya
    • Journal of KIBIM
    • /
    • v.8 no.4
    • /
    • pp.13-22
    • /
    • 2018
  • Future performance prediction of bridges is challenging task for structural engineers. Well-organized information from design, construction and operation stages is essential for the assessment of structures. Digital twin model is a new concept to realize more reliable data platform for management of infrastructures. Damage history including degradation of material, cracking, corrosion, etc. needs to be accumulated in the digital model. The digital model is linked to the analysis model for the assessment of structural performance considering changed mechanical properties of structural components. In this paper, initial definition digital twin model of a PSC-I girder bridge is proposed.

Study on Investigation and Analysis about Damage of Tunnels (국내외 터널구조물의 변상에 관한 조사 및 분석)

  • Bae, Gyu-Jin;Lee, Sung-Won;Cho, Mahn-Sup;Lee, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.3
    • /
    • pp.31-43
    • /
    • 2001
  • In this study, we carried out investigation and analysis on damages in tunnels on order to provide the basic information for the safety assessment of tunnels and to minimize the potential damage of the same kind as investigated. The frequencies of occurrence in terms of 4 items, i.e., service life interval, type of the damage, cause of the damage, and geological condition, were examined and summarized based on 44 foreign and domestic cases of tunnel damages. Also, we carried out a survey research of which the content included 28 questions on the tunnel safety assessment. The answers collected from domestic experts in tunneling suggested that the most probable cause of the tunnel damages was cracking in tunnels at 42~58%. They also suggested that the poor constrution work strongly caused the damages. Therefore, to ensure tunnel safety, high quality of constrution should be maintained as examined. The types of damage and their extent of influence on the overall tunnel safety are of practical importance to be used in the artficial intelligent system for tunnel safety assessment.

  • PDF

Conservation Status Diagnosis of Mural Painting in Geungnakjeon Hall of Daewonsa Temple, Boseong: Avalokitesvara Bodhisattva Mural and Buddhist Monk Bodhidharma Mural

  • Lee, Hwa Soo;Eom, Tae Ho;Jee, Bong Goo;Yi, Sun Jo;Yu, Yeong Gyeong;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.314-326
    • /
    • 2022
  • Investigation of conservation status, optical survey, infrared thermography, and ultrasonic examination were performed on Avalokitesvara Bodhisattva mural and Buddhist Monk Bodhidharma mural to determine the conservation status and physical properties. As a result of investigation of conservation status, the types of damage are largely divided into the wall and finishing layer damage, painting layer degradation, damage due to restoration materials, stains and contamination, and biological damage. As a result of the optical survey, drawing, stains, and repainted site were confirmed. Result of the infrared thermography, the delamination of the finishing layer was confirmed, and some locations and shapes of the wooden lath inside the wall were identified. The result of the 3D scanning, the deviation, and the separation of the wall was confirmed. As a result of ultrasonic examination, it was confirmed that the physical properties of the mural were identified and the ultrasonic speed was relatively low due to physical damage such as delamination and exfoliation of the finishing layer and cracking. Ultrasonic speed values were also high in some wall cracks or delamination, and it was confirmed by the infrared thermography results that the wooden lath inside the wall was located in those parts. It was possible to understand that the wooden lath inside the walls affects the ultrasonic speed during the ultrasonic examination. Therefore, management through periodic inspection of the relevant elements is necessary, and a countermeasure for damage that may occur in the future should be prepared along with intensive monitoring of the major damage identified in this diagnosis result.

Analysis for Properties of Particle or Short Fiber Reinforced Composites based on Micromechanics under Pure Shear (전단응력하의 분산형 복합재료에 미시역학적인 특성평가)

  • 조영태;임광희
    • Composites Research
    • /
    • v.15 no.3
    • /
    • pp.11-17
    • /
    • 2002
  • Cracking of the reinforcements is a significant damage mode in particle or short-fiber reinforced composites because the broken reinforcements lose load carrying capacity. This paper deals with elastic stress distributions and load carrying capacity of intact and cracked ellipsoidal inhomogeneities. Three dimensional finite element analysis has been carried out on intact and broken ellipsoidal inhomogeneities in all infinite body under pure shear. For the intact inhomogeneity, the stress distribution is uniform in the inhomogeneity and non-uniform in the surrounding matrix. On the other hand, for the broken inhomogeneity, the stress in the region near crack surface is considerably released and the stress distribution becomes more complex. The average stress in the inhomogeneity represents its load carrying capacity, and the difference of average stresses between the intact and broken inhomogeneities indicates the loss of load carrying capacity due to cracking damage. The broken inhomogeneity with higher aspect ratio maintains higher load carrying capacity.

The Effect of the CFRP/GFRP Composite Thickness on AE Characteristics and Mixed Mode Crack Behavior (CFRP/GFRP 적층복합재의 두께가 혼합모드 균열거동과 AE에 미치는 영향)

  • Yun, Yu-Seong;Kim, Da-Jin-Sol;Kwon, Oh-Heon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.9-14
    • /
    • 2014
  • Recently many efforts and researches have been done to cope with industrial facilities that require a low energy machines due to the gradual depletion of the natural resources. The fiber-reinforced composite materials in general have good properties and have the proper mechanical properties according to the change of the ply sequences and fiber distribution types. However, in the fiber-reinforced composite material, there are several problems, including fiber breaking, peeling, layer lamination, fiber cracking that can not be seen from the metallic material. Particularly, the fracture and delamination are likely to be affected by the thickness of the stacking laminates when the bi-material laminated structure is subjected to a load of the mixed mode. In this study, we investigated the effect of the thickness ratio of the difference in the CFRP/GFRP bi-material laminate composites by measuring the cracking behavior and the AE characteristics in a mixed mode loading, which may be generated in the actual structure. The results show that the thickness of the CFRP becomes more thick, the mode I energy release rate becomes a larger, and also the influence of mode I is greater than that of mode II. In addition, AE amplitude which shows the level of the damage in the structure was obtained the more damage in the CFRP with the thin thickness.

Thermal Stress Evaluation by Elastic-Creep Analysis during Start-up of Boiler Header (보일러 헤더 기동시의 탄성 크리프 해석에 의한 열응력 평가)

  • Shin, Kyu-In;Yoon, Kee-Bong
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.17-22
    • /
    • 2009
  • Thermal stress and elastic creeping stress analysis was conducted by finite element method to simulate start-up process of a boiler header of 500MW standard fossil power plant. Start-up temperature and operating pressure history were simplified from the real field data and they were used for the thermal stress analysis. Two kinds of thermal stress analysis were considered. In the first case only temperature increase was considered and in the second case both of temperature and operating pressure histories were considered. In the first analysis peak stress was occurred during the temperature increase from the room temperature. Hence cracking or fracture may occur at the temperature far below the operating maximum temperature. In the results of the second analysis von Mises stress appeared to be higher after the second temperature increase. This is due to internal pressure increase not due to the thermal stress. When the stress components of radial(r), hoop($\theta$) and longitudinal(z) stress were investigated, compression hoop stress was occurred at inner surface of the stub tube when the temperature increased from room temperature to elevated temperature. Then it was changed to tension hoop stress and increased because of the operating pressure. It was expected that frequent start-up and shut-down operations could cause thermal fatigue damage and cracking at the stub tube hole in the header. Elastic-creeping analysis was also carried out to investigate the stress relaxation due to creep and stabilized stress after considerable elapsed time. The results could be used for assessing the creep damage and the residual life of the boiler header during the long-tenn service.