• Title/Summary/Keyword: crack-crack combination

Search Result 154, Processing Time 0.035 seconds

Effect of Process Parameters on Laser Overlay Behavior of Fe-based Alloy Powder on Aluminum Substrate (공정 변수에 따른 Al 모재와 Fe계 합금 분말의 레이저 오버레이층 거동)

  • Yoo, Yeon-Gon;Kang, Nam-Hyun;Kim, Cheol-Hee;Kim, Jeong-Han;Kim, Mok-Soon
    • Journal of Welding and Joining
    • /
    • v.25 no.1
    • /
    • pp.30-36
    • /
    • 2007
  • A joining of dissimilar metal combination faces significant problems such as poor strength and cracking associated with brittle intermetallic compounds(IMC) formed. An application of laser allows low heat input; leading to less dilution and smaller heat affected zone. The $CO_2$ laser overlay was conducted on an AC2B alloy with feeding Fe-based powders. The overlay area was significantly influenced from the travel velocity rather than the powder feeding rate. The interface between the overlay and substrate consisted of the hard and brittle IMC($FeAl_3,\;Fe_3Al,\;Fe_2Al_5$), which initiating and propagating the crack. The reciprocating test for the slide wear was conducted on a multi-pass overlay experiment. Comparing with the multi-pass overlay with no overlap, the overlay with 50% overlap showed better wear resistance.

Modeling of nonlinear response of R/C shear deficient t-beam subjected to cyclic loading

  • Hawileh, R.A.;Abdalla, J.A.;Tanarslan, M.H.
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.419-434
    • /
    • 2012
  • This paper presents a finite element (FE) model for predicting the nonlinear response and behavior of a reinforced concrete T-beam deficient in shear under cyclic loading. Cracking loads, failure loads, response hysteresis envelopes and crack patterns were used as bench mark for comparison between experimental and FE results. A parametric study was carried out to predict the optimum combination of the open and close crack shear transfer coefficients (${\beta}_t$ and ${\beta}_c$) of the constitutive material model for concrete. It is concluded that when both shear transfer coefficients are equal to 0.2 the FE results gave the best correlation with the experimental results. The results were also verified on a rectangular shear deficient beam (R-beam) tested under cyclic loading and it is concluded that the variation of section geometry has no effect on the optimum choice of the values of shear transfer coefficients of 0.2. In addition, a parametric study based on the variation of concrete compressive strength, was carried out on the T-beam and it is observed that the variation of concrete compressive strength has little effect on the deflection. Further conclusions and observations were also drawn.

An Experimental Study on Durability of Mortar and Concrete using Shrinkage reducing typed Superplasticizer (수축저감형 혼화제를 이용한 모르타르 및 콘크리트의 물리적 특성에 관한 기초적 연구)

  • Woo, Hyung-Min;Park, Hee-Gon;Lee, Young-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.561-569
    • /
    • 2016
  • Concrete is cheap, easy to deal with, and the quality is satisfactory. Also, it is one of the easiest materials to get because chemical composition of cement is similar to chemical composition of surface. On the other hand, it is so vulnerable to transform because of weak binding capacity and low binding energy that it produces cracks. Cracks decline durability, usability, safety of structures and damage exterior. In order to decline drying shrinkage crack, this study used shrinkage reducing typed Superplasticizer, which is combination of and water-reducing agent for convenience, different with existing study using AE agent, water-reducing agent, shrinkage reducing agent,. Considering SRS field application possibility, this study planned to mix concrete and mortar generally used in ready-mixed concrete company and did basic experiment depending on a change of SRS content ratio and admixture. Based on the experiment result. It is judged that SRS admixture 2% is proper ratio when Given the intensity and length change. Also mass combination will conduct follow-up studies.

Effect of Structural Geometry and Crack Location on Crack Driving Forces for Cracks in Welds (용접부 균열의 균열진전력에 대한 구조물 형상과 균열 위치의 영향)

  • Oh Chang-Kyun;Kim Jong-Sung;Jin Tae-Eun;Kim Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.8 s.251
    • /
    • pp.931-940
    • /
    • 2006
  • Defect assessment of a weld zone is important in fitness-for-service evaluation of plant components. Typically a J and $C^*$ estimation method for a defective homogeneous component is extended to a mismatched component, by incorporating the effect due to the strength mismatch between the weld metal and the base material. The key element is a mismatch limit load. For instance, the R6/R5 procedure employs an equivalent material concept, defined by a mismatch limit load. A premise is that if a proper mismatch limit load solution is available, the same concept can be used for any defect location (either a weld centre defect or a heat affected zone (HAZ) defect) and for any material combination (either two-material or multi-material combinations; either similar or dissimilar joints). However, validation is still limited, and thus a more systematic investigation is needed to generalise the suggestion to any geometry, any defect location and any material combination. This paper describes the effect of structural geometry on the $C^*$ integral for defective similar welds, based on systematic elastic-creep 2-D and 3-D finite element (FE) analyses, to attempt to elucidate the questions given above. It is found that the existing 'equivalent material' concept is valid only for limited cases, although it provides conservative estimates of $C^*$ for most of cases. A modification to the existing equivalent material concept is suggested to improve accuracy.

The Effect of Fiber Volume Fraction on the Tension Softening Behavior of Steel Fiber-Reinforced Ultra High Strength Concrete (섬유혼입률이 강섬유보강 초고강도 콘크리트의 인장연화거동에 미치는 영향)

  • Kang, Su-Tae;Hong, Ki-Nam;Han, Sang-Hoon;Kim, Sung-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.1
    • /
    • pp.13-20
    • /
    • 2009
  • The influence of steel fiber volume on the tension softening behavior in steel fiber-reinforced ultra high strength concrete was investigated. Three-point bending test (TPBT) with notched beams was performed and inverse analysis method by Uchida et al. was adopted to obtain the tension softening behaviors from the results of TPBT. It could be found that the intial stiffness was constant regardless of steel fiber volume, the increase of steel fiber volume fraction made the tensile strength higher, but all of the curves converged on an asymptote with a crack width. It was proposed the equation of softening curve expressed by combination of plastic behavior part and exponential descending behavior part considering the steel fiber volume fraction and $\omega_0$, which is corresponding to the maximum crack width of plastic area. Thereafter, the crack propagation analysis using finite element method with smeared crack model was also carried out and it was confirmed that the proposed equation had a good agreement with the experimental results.

Pixel-level Crack Detection in X-ray Computed Tomography Image of Granite using Deep Learning (딥러닝을 이용한 화강암 X-ray CT 영상에서의 균열 검출에 관한 연구)

  • Hyun, Seokhwan;Lee, Jun Sung;Jeon, Seonghwan;Kim, Yejin;Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.184-196
    • /
    • 2019
  • This study aims to extract a 3D image of micro-cracks generated by hydraulic fracturing tests, using the deep learning method and X-ray computed tomography images. The pixel-level cracks are difficult to be detected via conventional image processing methods, such as global thresholding, canny edge detection, and the region growing method. Thus, the convolutional neural network-based encoder-decoder network is adapted to extract and analyze the micro-crack quantitatively. The number of training data can be acquired by dividing, rotating, and flipping images and the optimum combination for the image augmentation method is verified. Application of the optimal image augmentation method shows enhanced performance for not only the validation dataset but also the test dataset. In addition, the influence of the original number of training data to the performance of the deep learning-based neural network is confirmed, and it leads to succeed the pixel-level crack detection.

The Explosion-proof Performance of HPFRCC According to Fiber Combination and Mixing Ratio (섬유조합 및 혼입율 변화에 따른 HPFRCC의 방폭성능)

  • Lee, Jea-Hyeon;Lee, Jong-Tae;Jung, Woung-Seon;Jo, Sung-Jun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.88-89
    • /
    • 2017
  • Due to the increase in the usage of explosive materials and terrorism, the interest towards the superior explosion protective HPFRCC has risen. In existing research, the optimum ratio for solving the problematic problems such as the optimum fiber incorporation rate and the self-shrinkage crack of HPFRCC had been derived. However, there had been few or even no research upon how effective HPFRCC would perform protective explosion-proof in actual explosion. Therefore, this research compared the explosion-proof performance of HPFRCC according to fiber commination and mixing ratio. As a result, the combination of steel fiber and organic fiber showed excellent flow and strength, and it also improved the explosion resistance.

  • PDF

Properties of Fire Endurance of High Performance RC Column with Laterral Confinement Method (횡구속 방법에 따른 고성능 RC 기둥 콘크리트의 내화특성)

  • Hwang Yin Seong;Kim Ki-Hoon;Bae Yeoun Ki;Lee Bo Hyeong;Lee Jae Sam;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.553-556
    • /
    • 2004
  • This paper is to investigate the spalling and fire endurance of high performance RC column member with PP fiber and lateral confinement of metal lath and non fire resistance removal type form. According to test results, combination of PP fiber and metal lath as well as use fire resistance non removal type form had favorable fire resistance by discharging internal vapour pressure and lateral confining. After fire endurance test, compressive strength decreased markedly caused by internal expansion pressure and crack. Residual strength of plain concrete was decreased to $22\%$. The use of PP fiber and lateral confinement of metal lath and non removal type form enhanced the residual strength above $40\%$. Especially, the combination of $0.1\%$ of PP fiber and lateral confinement with the level of 2.3T exhibited more than $51\%$ of residual strength. Therefore, to improve fire endurance and spalling resistance, the combination of $0.1\%$ of PP fiber and metal lath with 2.3T can be the proper measure.

  • PDF

Performance of Repaired Structural Walls with Different Shear Span Ratios (전단스팬비가 다른 보수된 벽체의 성능평가)

  • Han, Sang-Whan;Oh, Chang-Hak;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • The purpose of this study is to evaluate the capacities of repaired structural walls with different shear span ratios(1, 2, 3). Experimental tests were carried out. In this study three isolated large-scale wall specimens were made. The original wall specimens were tested until the drift reaches more than 3%. The region of the damaged specimen with the crack larger than 0.2 mm is replaced by new concrete. Also, severly distorted reinforcements were also replaced by new reinforcements. The crack smaller than 0.2 mm was cured by epoxy resin. Because of the space limitation of the laboratory the dimensions of all walls are the same. The shear-span ratio was controlled by the combination of axial and lateral force using the special test setting. All specimens were tested using the incremental quasi static cyclic load until failure occurs. Test results show that strength of repaired walls was almost equivalent to that of original walls. However, deformation capacities of repaired wall specimens are inferior to the original wall specimens.

Performance comparison of shear walls with openings designed using elastic stress and genetic evolutionary structural optimization methods

  • Zhang, Hu Z.;Liu, Xia;Yi, Wei J.;Deng, Yao H.
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.303-314
    • /
    • 2018
  • Shear walls are a typical member under a complex stress state and have complicated mechanical properties and failure modes. The separated-elements model Genetic Evolutionary Structural Optimization (GESO), which is a combination of an elastic-plastic stress method and an optimization method, has been introduced in the literature for designing such members. Although the separated-elements model GESO method is well recognized due to its stability, feasibility, and economy, its adequacy has not been experimentally verified. This paper seeks to validate the adequacy of the separated-elements model GESO method against experimental data and demonstrate its feasibility and advantages over the traditional elastic stress method. Two types of reinforced concrete shear wall specimens, which had the location of an opening in the middle bottom and the center region, respectively, were utilized for this study. For each type, two specimens were designed using the separated-elements model GESO method and elastic stress method, respectively. All specimens were subjected to a constant vertical load and an incremental lateral load until failure. Test results indicated that the ultimate bearing capacity, failure modes, and main crack types of the shear walls designed using the two methods were similar, but the ductility indexes including the stiffness degradation, deformability, reinforcement yielding, and crack development of the specimens designed using the separated-elements model GESO method were superior to those using the elastic stress method. Additionally, the shear walls designed using the separated-elements model GESO method, had a reinforcement layout which could closely resist the actual critical stress, and thus a reduced amount of steel bars were required for such shear walls.