• 제목/요약/키워드: covering surface temperature

검색결과 72건 처리시간 0.026초

섬유복합모르터의 뿜칠마감에 의한 고강도콘크리트 기둥부재의 폭렬방지 (Spatting Resistance of High Strength RC Column Covering Spray-on Materials of Fiber Composite Spray Mortar(FCSM))

  • 송용원;한동엽;이건철;고경택;김진수;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.5-8
    • /
    • 2006
  • High strength concrete has been increasingly used in high rue building and it is very obvious re consider fire resistance performance of that. Unlike the normal strength concrete, high strength concrete in sudden elevating temperature at fire is susceptible to spalling with severe explosion and surface split, due to high density of concrete. In order to endure the spalling, inner space temperature of concrete should be control less than certain point. Therefore this study investigated the influence of covering materials on high strength concrete finishing spray-on materials of fiber composite spray mortar(FCSM). Both polypropylene(PP) and polyvinyl alcohol(PVA) fiber were used in this test. Test showed that concrete, covering 18mm mortar containing PVA fiber and confining metal lath 2.3mm thickness, decreased 50% of main bar ambient temperature. compared with control concrete. In addition, concrete covering 18mm mortar without fiber caused falling of covering materials and then it was exposed in elevating temperature. As a result, spatting of the concrete occurred same as control concrete. However, concrete covering spray-on mortar containing PVA or PP fiber resisted spatting occurrence.

  • PDF

콘크리트 도로 포장의 초기 온도 분포 분석 (Temperature Patterns in Concrete Pavements at Very Early Ages)

  • 김성민;남정희
    • 한국도로학회논문집
    • /
    • 제7권3호
    • /
    • pp.79-91
    • /
    • 2005
  • 포틀랜드 시멘트 콘크리트 도로 포장의 온도 패턴을 콘크리트 타설시부터 최근에 개발된 저렴하며 획기적인 센서를 이용하여 측정하였으며 그 결과를 분석하였다. 콘크리트 포장의 온도 측정은 여러 다른 지역에서 여러 다른 두께를 가진 콘크리트 포장에서 수행하였다. 콘크리트 포장의 온도 패턴은 깊이방향과 콘크리트 타설시간에 따른 종방향의 변화를 고려하여 분석하였으며, 포장 표면의 반사율, 그늘, 덮음막 등이 콘크리트 포장의 온도 패턴에 미치는 영향을 분석하였다. 본 연구 결과에서 콘크리트를 타설한 날의 콘크리트 포장의 최고 온도는 종방향을 따라 타설 시간이 다름으로 인해 생기는 차이가 두드러지는 것을 알 수 있었다. 콘크리트의 영점응력온도(zero-stress temperature)는 타설한 날의 최고 온도와 직접적인 연관이 있으므로 타설 시간에 따른 최고 온도의 차이는 콘크리트 포장의 거동 및 성능에 크게 영향을 미칠 수 있다. 또한 콘크리트 포장의 표면 상태 (표면 색상, 그늘 유무, 덮음막 유무 등)도 콘크리트 포장의 온도 패턴에 큰 영향을 미치는 인자인 것으로 분석되었다.

  • PDF

MONITORING OF LAND SURFACE TEMPERATURE CHANGE OF THE NORTHEAST REGION IN CHINA BY MODIS DATA

  • SHAO, Ming;Park, Jong-Geol;YASUDA, Yoshizumi
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.927-929
    • /
    • 2003
  • Using received northeast region in China of Terra/MODIS data at Tokyo University of information Sciences. Make monthly division Land Surface Temperature maximum composite image. Using monthly division Land Surface Temperature maximum composite image, considered characteristic of monthly variation of Land surface temperature and relation with land covering and NDVI at the northeast region in China.

  • PDF

공동주택 단지 내 지반 특성 및 지반 구성에 따른 열적 특성에 관한 연구 (The Effect of the Ground Composition on Thermal Environment in Multi -residential Building Block)

  • 황효근;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.88-97
    • /
    • 2009
  • In these days, it attracts our attention to create a green outdoor environment around the building block in urban area. Green space and permeable ground covering are increased by laws and regulations. According to these trends, variety researches for improving outdoor environment are accomplished at this moment. However, the problems for outdoor environment such as heat island effect and air contaminant in urban area are still reported. The purpose of this study is to examine the variables to affect the formation of outdoor thermal environment by quantitative analysis. As a initial study, in this paper, the effect of ground composition on changes of surface temperature and heat flux in multi-residential building were analyzed by field measurement and numerical simulation. Through field measurement, the surface temperature and heat flux of artificial ground in multi-residential building in Suwon city were measured. The result showed that the surface temperature was decreased by about $20^{\circ}C$ with afforestation of artificial ground compared with those of concrete covering. Moreover, the inner temperature of artificial ground was changed as same behaviors of outdoor temperature changes to depths of 20cm. In simulation, the effect of soil types and depth of artificial ground on the changes of the surface temperature and heat flux were analyzed. As results, the natural soil ground was more effective against lowering the surface temperature than any other cases in the analyzed cases.

도시 내 공원과 하천의 기온변화율과 기온완화효과에 관한 연구 (A Study on the Temperature Variation Rate and Temperature Controlling Effect of Parks and Rivers in a City)

  • 이강국;김태우;서원덕;홍원화
    • KIEAE Journal
    • /
    • 제11권3호
    • /
    • pp.3-9
    • /
    • 2011
  • For urban development, natural covering area such as urban green or river is more rapidly reducing than artificial surface covering area like concrete or asphalt, so thermal environment in a city is being drastically deteriorated. Recently, since people recognize the importance of parks or rivers in a city which play roles as an environmental buffer in it, many studies and policies consider how to improve the life quality of citizens and urban environment. This study aims to examine the status of thermal environment variation in the parks and rivers of the city which is the subject of this research and provide foundational data for urban environment plans through research on temperature variation rate and temperature controlling effect.

경의선장단역증기기관차의 부식방지를 위한 왁스계 피복제 내후성 시험 연구 (A Study on the Testing of Weather Resistance of Anti-corrosion Wax Covering Agents in the Locomotive at Jangdan Station of Gyeongui Line)

  • 송원준;김미현;안병찬;정희돈
    • 보존과학회지
    • /
    • 제25권4호
    • /
    • pp.373-381
    • /
    • 2009
  • 야외 전시되는 철제문화재 보존을 위해서 유물 표면을 피복처리 하는 것은 부식방지의 대표적인 방법이다. 근대문화유산 제78호 경의선장단역증기기관차는 보존조치 후 노천에서 전시될 예정이라서 기관차의 재부식 예방에 효과적인 표면 피복재를 내후성 실험을 통해 선별하였다. 실험재료는 기관차 표면 피복에 주로 사용되는 미정질 왁스 2종과 봉밀왁스를 기반으로 제조한 혼합왁스를 선별하였다. 실험방법은 3종의 왁스를 기관차 시편에 각각 피복하고 ISO 4892-1981 기준에 따라 제논아크촉진내후성시험기 속에서 1000시간 내후성 시험을 한 후 그 변화상을 비교 조사하였다. 실험결과 봉밀 왁스는 400시간 이후부터 표면에 백화현상이 발생하면서 노화하였고 미정질 왁스 2종은 800시간 이후부터 변화를 보였다. 시험전과 후 수분접촉각의 변화 역시 봉밀 왁스 보다 미정질 왁스가 적게 나타났다. 따라서 미정질 왁스 중 특히 고온형이 내후성과 수분 차단력이 가장 뛰어난 것으로 확인되어서 이것으로 증기기관차의 표면을 피복하게 되었다.

  • PDF

일중 피복온실의 관류열전달계수 산정 (Estimation of Overall Heat Transfer Coefficient for Single Layer Covering in Greenhouse)

  • 황영윤;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제22권2호
    • /
    • pp.108-115
    • /
    • 2013
  • 본 연구의 목적은 일중피복온실의 피복재에 대하여 우리나라 환경에 적합한 관류열전달계수를 산정하는 방법을 찾아내고 검증하여 다양한 온실조건 및 환경조건에서 관류열전달계수를 산정할 수 있는 모델을 제시하는 것이다. 온실내부 및 외부온도와 피복재 표면온도와의 상관관계를 분석한 결과 주간 및 야간 온도를 모두 고려하였을 때보다 야간온도만을 고려하였을 경우가 상관성이 훨씬 더 높은 것으로 나타났다. 피복재의 표면온도가 온실의 외부온도보다는 내부온도와 상관성이 더 높은 것으로 나타났다. 관류열전달계수를 산정하는데 사용된 5가지 종류의 대류 및 복사열전달계수 산정식을 비교한 결과 Kittas가 제안한 대류 및 복사열전달계수 산정식이 가장 적합한 것으로 나타났다. 피복재 표면온도의 측정값과 계산 값의 상관성을 분석한 결과 직선의 기울기는 1.009이고 절편은 0.001이며 결정계수가 0.98로 나타나 본 연구에서 제시된 관류열전달계수 산정모델이 신뢰성이 있음을 확인할 수 있었다. 온실내부로부터 피복재 내부표면으로 전달되는 열흐름량의 경우 모든 풍속구간에 대해 대류열전달량이 복사열전달량보다 더 컸으며 풍속이 증가할수록 그 차이가 증가하였다. 외부표면에서 손실되는 열흐름량의 경우 풍속이 낮을 때에는 대류열전달량에 비해 복사열전달량이 더 컸으나 풍속이 증가함에 따라 그 차이는 점점 줄어들어 풍속이 높을 때에는 대류열전달량이 더 커지는 것으로 나타났다. 피복재 외부 표면의 대류열전달량은 내부표면의 대류열전달량에 직선적으로 비례하여 증가하는 것으로 나타났다. 풍속이 증가함에 따라 관류열전달계수는 증가하고 피복재의 표면 온도는 감소하는 것을 확인할 수 있었고, 변화추세를 보면 관류열전달계수는 거듭제곱함수와 그리고 표면온도는 로그함수와 잘 일치하였다.

플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가 (Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses)

  • 이현우;김영식;심상연;이종원;소레이멘디옵
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.270-278
    • /
    • 2013
  • 본 연구는 우리나라 상업용 온실의 보온성능 및 광투과 성능을 개선할 수 있는 피복방식을 결정하는데 필요한 자료를 제공하기 위하여 토마토 재배용 실험온실의 세 가지 피복방식에 대한 보온효과 및 광투과 특성을 평가하였으며 결과를 요약하면 다음과 같다. 공기주입 이중피복온실과 관행 이중피복온실의 관류열손실량이 거의 비슷한 것으로 나타났으나 외부기온이 비슷할 때 피복재와 보온커튼 사이의 온도가 공기주입 이중피복온실이 더 낮게 나타난 것은 공기주입 이중피복온실의 경우 나비식 천창의 틈새로 인한 환기전열손실이 크기 때문인 것으로 판단된다. 따라서 공기주입 이중피복온실에서 나비식 천창을 사용할 경우 틈새 환기전열손실을 줄일 수 있는 대책이 수립되어야 할 것으로 판단된다. 일중피복 온실과 관행이중피복온실의 관류열전달계수에 대한 온실 실험결과와 모형실험결과를 비교한 결과 모두 비슷한 값을 나타내었다. 이러한 결과는 측정된 관류열전달계수가 타당성 있는 값임을 보여주는 것이며 향후 온실의 난방설계시 직접 활용할 수 있을 것으로 기대된다. 공기주입 이중피복온실이 비록 일중피복온실보다는 광투과율이 낮으나 동일한 이중피복온실인 관행이중피복온실보다 광투과율이 높기 때문에 보온을 위해서 이중피복을 설치할 경우에 광투과율을 확보하기 위해서는 공기주입 이중피복방식을 채택하는 것이 바람직할 것으로 판단된다. 공기주입 이중피복온실에 비해 일중피복온실의 피복재 내부표면에서 발생하는 결로량이 큰 이유는 일중피복온실의 피복재 내부표면온도가 훨씬 낮기 때문에 피복재에서의 포화습도가 작아져 내부공기의 절대습도와의 차이가 증가하기 때문인 것으로 판단된다.

버블시트 피복양생법에 의한 소성 및 건조수축 균열저감 (Plastic and Drying Shrinkage Cracking Reduction by the Bubble Sheet Curing)

  • 이정교;한천구
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.211-217
    • /
    • 2016
  • 본 연구에서는 2015년 가을철 실제 시공중인 고층 아파트를 대상으로 1중 백색 버블시트로 타설된 콘크리트의 표면을 덮어주는 버블시트 피복양생 공법과 표면을 노출한 채로 양생없이 유지하는 표면노출 방법간을 비교하여 소성 및 건조수축균열의 저감정도를 분석하였다. 실험 결과, 버블시트를 시공하였을 경우, 수화열 및 적산온도는 표면노출보다 약간 높았고, 바닥 균열의 갯수, 길이, 최대 균열폭, 균열 면적 모두 현저하게 적은 값이 측정되었다. 따라서 가을철 버블시트를 타설된 콘크리트 표면에 적용 할 경우에는 소성 및 건조수축균열을 획기적으로 방지할 수 있는 효과적인 표면피복 양생공법인 것으로 판단되었다.

뿜칠피복재를 사용한 고강도 콘크리트 부재의 내화피복두께에 관한 실험적 연구 (An Experimental Study on the Fireproof Covering Thickness of High Strength Concrete Members with Spray Coating)

  • 이태규
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.41-46
    • /
    • 2010
  • 고강도 콘크리트는 대형 사회기반 구조물로서 많이 활용되고 있다. 고강도 콘크리트는 우수한 재료적 성능과 내구성을 확보하고 있지만 반면에 화재에 대한 급작스러운 폭렬현상으로 인하여 구조적인 문제를 야기시키기도 한다. 따라서 본 연구에서는 콘크리트 피복두께에 추가하여 내화피복재를 사용함으로써 내화피복두께에 따른 콘크리트의 내화성능을 평가하고 최적의 내화피복두께를 산정하는 실험적 연구를 수행하였다. 내화피복재를 10mm 간격으로 증가시키면서 실험을 수행한 결과 콘크리트의 내화성능이 크게 향상됨을 볼 수 있었으며, 최적의 내화피복두께는 약 1~3mm로 산정되었다. 또한 폭렬에 의하여 급작스러운 콘크리트 내부의 온도상승 이후 기화열에 의한 열손실로 완만하게 온도가 상승되는 현상이 실험적으로 관측되었다. PP 섬유는 약 $200^{\circ}C$ 부근에서 용해되어 고온에서는 빈 채널만 남게 되므로 내부 증기압을 저감시켜주는 역할도 관측되었다.