• Title/Summary/Keyword: covered stent

Search Result 30, Processing Time 0.028 seconds

Covered Stents for the Endovascular Treatment of a Direct Carotid Cavernous Fistula : Single Center Experiences with 10 Cases

  • Li, Ke;Cho, Young Dae;Kim, Kang Min;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.12-18
    • /
    • 2015
  • Objective : Covered stent has been recently reported as an effective alternative treatment for direct carotid cavernous fistulas (DCCFs). The purpose of this study is to describe our experiences with the treatment of DCCF with covered stents and to evaluate whether a covered stent has a potential to be used as the first choice in selected cases. Methods : From February 2009 through July 2013, 10 patients underwent covered stent placement for a DCCF occlusion. Clinical and angiographic data were retrospectively reviewed. Results : Covered stent placement was performed for five patients primarily as the first choice and in the other five as an alternative option. Access and deployment of a covered stent was successful in all patients (100%) and total occlusion of the fistula was achieved in nine (90%). Complete occlusion immediately after the procedure was obtained in five patients (50%). Endoleak persisted in five patients and the fistulae were found to be completely occluded by one month control angiography in four. The other patient underwent additional coil embolization by a transvenous approach. Balloon inflation-related arterial dissection during the procedure was noted in two cases; healing was noted at follow-up angiography. One patient suffered an asymptomatic internal carotid artery occlusion noted seven months post-treatment. Conclusion : Although endoleak is currently a common roadblock, our experience demonstrates that a covered stent has the potential to be used as the first choice in DCCF; this potential is likely to increase as experience with this device accumulates and the materials continue to improve.

Bilateral Vertebral Artery Dissecting Aneurysms Presenting with Subarachnoid Hemorrhage Treated by Staged Coil Trapping and Covered Stents Graft

  • Yoon, Seok-Mann;Shim, Jai-Joon;Kim, Sung-Ho;Chang, Jae-Chil
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.155-159
    • /
    • 2012
  • The treatment of bilateral vertebral artery dissecting aneurysms (VADAs) presenting with subarachnoid hemorrhage (SAH) is still challenging. The authors report a rare case of bilateral VADA treated with coil trapping of ruptured VADA and covered stents implantation after multiple unsuccessful stent assisted coiling of the contralateral unruptured VADA. A 44-year-old woman was admitted to our hospital because of severe headache and sudden stuporous consciousness. Brain CT showed thick SAH and intraventricular hemorrhage. Cerebral angiography demonstrated bilateral VADA. Based on the SAH pattern and aneurysm configurations, the right VADA was considered ruptured. This was trapped with endovascular coils without difficulty. One month later, the contralateral unruptured VADA was protected using a stent-within-a-stent technique, but marked enlargement of the left VADA was detected by 8-months follow-up angiography. Subsequently two times coil packing for pseudosacs resulted in near complete occlusion of left VADA. However, it continued to grow. Covered stents graft below the posterior inferior cerebellar artery (PICA) origin and a coronary stent implantation across the origin of the PICA resulted in near complete obliteration of the VADA. Covered stent graft can be used as a last therapeutic option for the management of VADA, which requires absolute preservation of VA flow.

Novel Endoscopic Stent for Anastomotic Leaks after Total Gastrectomy Using an Anchoring Thread and Fully Covering Thick Membrane: Prevention of Embedding and Migration

  • Jung, Gum Mo;Lee, Seung Hyun;Myung, Dae Seong;Lee, Wan Sik;Joo, Young Eun;Jung, Mi Ran;Ryu, Seong Yeob;Park, Young Kyu;Cho, Sung Bum
    • Journal of Gastric Cancer
    • /
    • v.18 no.1
    • /
    • pp.37-47
    • /
    • 2018
  • Purpose: The endoscopic management of a fully covered self-expandable metal stent (SEMS) has been suggested for the primary treatment of patients with anastomotic leaks after total gastrectomy. Embedded stents due to tissue ingrowth and migration are the main obstacles in endoscopic stent management. Materials and Methods: The effectiveness and safety of endoscopic management were evaluated for anastomotic leaks when using a benign fully covered SEMS with an anchoring thread and thick silicone covering the membrane to prevent stent embedding and migration. We retrospectively reviewed the data of 14 consecutive patients with gastric cancer and anastomotic leaks after total gastrectomy treated from January 2009 to December 2016. Results: The technical success rate of endoscopic stent replacement was 100%, and the rate of complete leaks closure was 85.7% (n=12). The mean size of leaks was 13.1 mm (range, 3-30 mm). The time interval from operation to stent replacement was 10.7 days (range, 3-35 days) and the interval from stent replacement to extraction was 32.3 days (range, 18-49 days). The complication rate was 14.1%, and included a single jejunal ulcer and delayed stricture at the site of leakage. No embedded stent or migration occurred. Two patients died due to progression of pneumonia and septic shock 2 weeks after stent replacement. Conclusions: A benign fully covered SEMS with an anchoring thread and thick membrane is an effective and safe stent in patients with anastomotic leaks after total gastrectomy. The novelty of this stent is that it provides complete prevention of stent migration and embedding, compared with conventional fully covered SEMS.

Percutaneous Transhepatic Treatment of Benign Bile Duct Strictures Using Retrievable Covered Stents: Long-Term Outcomes in 148 Patients

  • Byung Soo Im;Dong Il Gwon;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.889-900
    • /
    • 2022
  • Objective: To investigate the long-term outcomes of percutaneous treatment of benign biliary strictures using temporary placement of a retrievable expanded polytetrafluoroethylene (PTFE) covered stent. Materials and Methods: We retrospectively analyzed the outcomes of 148 patients (84 male and 64 female; age range, 11-92 years) who underwent percutaneous transhepatic placement and removal of a retrievable PTFE-covered stent for the treatment of benign biliary strictures between March 2007 and August 2019 through long-term follow-up. Ninety-two patients had treatment-naïve strictures and 56 had recurrent/refractory strictures. Results: Stent placement was technically successful in all 148 patients. The mean indwelling period of the stent was 2.4 months (median period, 2.3 months; range, 0.2-7.7 months). Stent migration, either early or late, occurred in 28 (18.9%) patients. Clinical success, defined as resolution of stricture after completing stent placement and removal, was achieved in 94.2% (131 of 139 patients). The overall complication rate was 15.5% (23 of 148 patients). During the mean follow-up of 60.2 months (median period, 52.7 months; range, 1.6-146.1 months), 37 patients had a recurrence of clinically significant strictures at 0.5-124.5 months after removal of biliary stent and catheter (median, 16.1 months). The primary patency rates at 1, 3, 5, 7, and 10 years after removal of biliary stent and catheter were 88.2%, 70.0%, 66.2%, 60.5%, and 54.5%, respectively. In the multivariable Cox proportional hazard regression analysis, sex, age, underlying disease, relation to surgery, stricture type, biliary stones, history of previous treatment, and stricture site were not significantly associated with the primary patency. Conclusion: Long-term outcomes suggest that percutaneous treatment of benign biliary strictures using temporary placement of retrievable PTFE-covered stents may be a clinically effective method.

First line Treatment of Traumatic Carotid Cavernous Fistulas Using Covered Stents at Level 1 Regional Trauma Center

  • Jeong, Sang Hoon;Lee, Jung Hwan;Choi, Hyuk Jin;Kim, Byung Chul;Yu, Seung Han;Lee, Jae Il
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.818-826
    • /
    • 2021
  • Objective : The widely accepted treatment option of a traumatic carotid cavernous fistula (TCCF) has been detachable balloon or coils based fistula occlusion. Recently, covered stent implantation has been proving an excellent results. The purpose of this study is to investigate our experiences with first line choice of covered stent implantation for TCCF at level 1 regional trauma center. Methods : From November 2004 to February 2020, 19 covered stents were used for treatment of 19 TCCF patients. Among them, 15 cases were first line treatment using covered stents. Clinical and angiographic data were retrospectively reviewed. Results : Procedures were technically successful in all 15 cases (100%). Immediate angiographic results after procedure were total occlusion in 12 patients (80%). All patients except two expired patients had image follow-up (mean 15 months). Recurred symptomatic three patients underwent additional treatments and achieved complete occlusion. Mean clinical follow-up duration was 32 months and results were modified Rankin Scale 1-2 in five, 3-4 in five, and 5 in three patients. Conclusion : The covered stent could be considered as fist line treatment option for treating TCCF patients especially in unstable vital sign. Larger samples and expanded follow-up are required to further develop their specifications and indications.

Endovascular Treatment for Common Iliac Artery Injury Complicating Lumbar Disc Surgery : Limited Usefulness of Temporary Balloon Occlusion

  • Nam, Taek-Kyun;Park, Seung-Won;Shim, Hyung-Jin;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.261-264
    • /
    • 2009
  • Vascular injury during lumbar disc surgery is a rare but potentially life-threatening complication. It has been managed by open vascular surgical repair. With recent technologic advance, endovascular treatment became one of effective treatment modalities. We present a case of a 32-year-old woman who suffered with common iliac artery injury during lumbar disc surgery that was treated successfully by endovascular repair with temporary balloon occlusion and subsequent insertion of a covered stent. Temporary balloon occlusion for 1.5 hours could stop bleeding, but growing pseudoaneurysm was identified at the injury site during the following 13 days. It seems that the temporary balloon occlusion can stall bleeding from arterial injury for considerable time duration, but cannot be a single treatment modality and requires subsequent insertion of a covered stent.

Development of Polymeric Coating Material for Effective Drug-eluting Stent (효율적인 약물 방출 스텐트 제조를 위한 고분자 코팅물질 개발)

  • Park, Tae-Hyun;Jo, Eun-Ae;Na, Kun
    • Polymer(Korea)
    • /
    • v.35 no.5
    • /
    • pp.483-487
    • /
    • 2011
  • For the preparation of effective non-vascular drug eluting stent (DES), pullulan acetate (PA) was investigated as a coating material for polytetrafluorethylene (PTFE)-covered stent. PA was coated on PTFE-covered stent (PTFE-stent) by dip coating technique, and then its surface morphology, drug release behavior and cellular toxicity were tested. Field emission-scanning electron microscopy (FE-SEM) result indicated that its surface was smoother after PA coating without any cracking. The sustained release behavior of paclitaxel from PA-coated PTFE membrane was observed for 80 days. Also, the biological stability of paclitaxel in the membrane was confirmed by annexin V binding assays. Furthermore, the antitumor activity was demonstrated by an in vivo test against CT-26 murine colorectal tumors. From the results, we concluded that PA was expected as a useful coating material to design an effective non-vascular DES.

Flexible covered stent ; development and clinic application (Flexible covered stent의 개발과 임상응용)

  • Suh, S.W.;Kim, I.Y.;Hong, T.M.;Kim, W.K.;Choo, S.W.;Do, Y.S.;Choo, I.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.335-336
    • /
    • 1996
  • Flexible, self-expanding metallic stent were developed using igzag wire bend and segmented polyurethane. Mechanical properties of these stents were tested using INSTRON. These stents were used for palliative treatment of mallignant esophagogastric strictures(3 case) and bawl preparation of collorectal obstruction(10 case). All stents were inserted with fluoroscopic guidance without techinal failures. According to the results, these stents are easy to insert, safe, and very effective for dilation of strictures in curved GI tract.

  • PDF

Postinfarct Ventricular Septal Defect after Coronary Covered Stent Implantation

  • Chon, Soon-Ho;Kim, Young-Hak;Kim, Hyuck;Chung, Won-Sang;Kang, Jeong-Ho;Shin, Kyung-Wook
    • Journal of Chest Surgery
    • /
    • v.45 no.1
    • /
    • pp.45-48
    • /
    • 2012
  • We report a case of a postinfarction ventricular septal defect caused by an acute recurrent occlusion after the implantation of a covered stent, which was performed as a rescue procedure for the ruptured left anterior descending artery during a percutaneous coronary intervention. Although the emergent implantation of a covered stent for the ruptured coronary arteries such as the left main coronary artery or the origins of the left anterior descending artery can be performed during a percutaneous coronary intervention, and a coronary bypass surgery should be considered in order to decrease the risk of complete occlusion, thus providing a superior long term patency.

Covered Self-expandable Metallic Stent Insertion as a Rescue Procedure for Postoperative Leakage after Primary Repair of Perforated Duodenal Ulcer (십이지장 궤양 천공 단순 봉합수술 후 완전 피막형 자가확장 금속 스텐트 삽입술로 치료된 봉합 부위 누출)

  • Yoo, Young Jin;Lee, Yong Kang;Lee, Joong Ho;Lee, Hyung Soon
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.262-266
    • /
    • 2018
  • Surgery has been the standard treatment for perforated duodenal ulcers, with mostly good results. However, the resolution of postoperative leakage after primary repair of perforated duodenal ulcer remains challenging. There are several choices for re-operation required in persistent leakage from perforated duodenal ulcers. However, many of these choices are complicated surgical procedures requiring prolonged general anesthesia that may increase the chances of morbidity and mortality. Several recent reports have demonstrated postoperative leakage after primary repair of a perforated duodenal ulcer treated with endoscopic insertion using a covered self-expandable metallic stent, with good clinical results. We report a case with postoperative leakage after primary repair of a perforated duodenal ulcer treated using a covered self-expandable metallic stent.