• Title/Summary/Keyword: cover-all

Search Result 1,128, Processing Time 0.031 seconds

Estimation of Rice and Soybean Growth Stage Using a Microwave Scatterometer (마이크로파 산란계를 이용한 벼, 콩 생육단계 추정)

  • Kim, Yi-Hyun;Hong, Suk-Young;Lee, Hoon-Yol;Lee, Jae-Eun;Lee, Kyung-Do
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.4
    • /
    • pp.503-510
    • /
    • 2012
  • Microwave radar can penetrate cloud cover regardless of weather conditions and can be used day and night. Especially a A ground-based polarimetric scatterometer operating at multiple frequencies can continuously monitor the crop conditions. We analyzed scattering characteristics of rice and soybean using pauli decomposition method. Surface scattering (${\alpha}$) is the dominant component over the entire stages for all bands and pauli decomposition value was the highest for L-band. Double bounce scattering (${\beta}$) and volume scattering (${\gamma}$) were approximately equal for C-band and volume scattering was higher than double bounce scattering for X-band in rice field. In soybean, double bounce scattering becomes higher than volume scattering during the R2 stage (DOY 224) and there was a significant difference between the two components after the R4 stage (DOY 242) for L-band. The maximum growth stage of soybean can also be detected using L-band double bounce scattering. The peak of double bounce effect coincides with the peak of growth biophysical variables on DOY 271. We found that pauli decomposition can provide insight on the relative magnitude of different scattering mechanisms during the rice and soybean growth cycle.

Establishment Efficiency of 'Zenith' Zoysiagrass by Plugging (한국잔디(Zoysia japonica 'Zenith')의 플러그 묘를 이용한 조성 효율)

  • Cho, Yun-Sik;Ahn, Sang-Hyun;Yang, Geun-Mo;Choi, Joon-Soo
    • Asian Journal of Turfgrass Science
    • /
    • v.21 no.1
    • /
    • pp.9-21
    • /
    • 2007
  • Research was initiated to examine establishment efficiency of zoysiagrass by plugging. Zoysiagrass is known to be a slowly establishing turfgrass species. Properly-treated zoysiagrass seed can speed up the establishment rate, while initial irrigation practice is intensively required after seeding. A planting method with small plugs($2.5{\times}2.5cm$) from seeding can overcome initial watering requirement. Establishment speed, however, can vary with planting dates, planting spaces, and plastic film cover in early stage. Establishment characteristics were investigated for two years by planting dates that were April 5, May 18, July 13, August 24 and October 29 in 2004 and April 6 in 2005. They were also compared with three different spaces($20{\times}20,\;25{\times}25,\;and\;30{\times}30cm$) and three different fertilizer levels(15, 30, and $45g\;N{\cdot}m^{-2}$). Ground coverage reached to 90% in plugs of 'Zenith' zoysiagrass planted on April 5. It increased suddenly in period of July to August, resulting in about 50% of full establishment rate. Establishment rates were significantly faster over 9% in plugs spaced at $20{\times}25cm$ than in those at $30{\times}30cm$. No significant differences were observed on the stolen number and stolen length in the study. Survival rate in zoysiagrass plug was over 90% at all plantings. These results demonstrated that zoysiagrass establishment using small plug from seeding is considered to be a safe and efficient method.

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

A Study of the Radiotherapy Techniques for the Breast Including Internal Mammary Lymph Nodes (유방 보존술 후 내유림프절을 포함하는 방사선치료 기법에 관한 연구)

  • Jeong, Kyoung-Keun;Shim, Su-Jung;You, Sei-Hwan;Kim, Yong-Bae;Keum, Ki-Chang;Kim, Jong-Dae;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.35-41
    • /
    • 2009
  • Purpose: This study was designed to determine the optimum radiotherapy technique for internal mammary node (IMN) irradiation after breast-conserving surgery. Materials and Methods: We selected ten cases of early stage partial mastectomy for plan comparison. Five of the patients were treated to the right-side breast and the rest of the patients were treated to the left-side breast. For each case, four different treatment plans were made to irradiate the entire breast, IMNs and supraclavicular lymph nodes (SCLs). The four planning techniques include a standard tangential field (STF), wide tangential field (WTF), partially wide tangential field (PWT) and a photon-electron mixed field (PEM). We prescribed a dose of 50.4 Gy to the SCL field at a 3 cm depth and isocenter of the breast field. Results: The dose distribution showed clear characteristics depending on the technique used. All of the techniques covered the breast tissue well. IMN coverage was also good, except for the STF, which was not intended to cover IMNs. For the cases of the left-side breasts, the volume of the heart that received more than 30 Gy was larger (in order) for the WTF, PWT, PEM and STF. For radiation pneumonitis normal tissue complication probability (NTCP), the PWT showed the best results followed by the STF. Conclusion: Despite the variety of patient body shapes, the PWT technique showed the best results for coverage of IMNs and for reducing the lung and heart dose.

Analysis of the Cold Air Flow in Suwon for the Application of Urban Wind Corridor (도시 바람길 활용을 위한 수원시 찬공기 유동 분석)

  • CHA, Jae-Gyu;CHOI, Tae-Young;KANG, Da-In;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.24-38
    • /
    • 2019
  • Due to the dramatic spatial changes caused by industrialization, environmental problems such as air pollution and urban heat island phenomenon, etc. are occurring in cities. In this case, the wind corridor, which is a passage through which fresh and cool air generated in forests outside cities move to the downtown, can be used as a spatial planning method for improving urban environmental problems. Cold air is determined by the characteristics of the flow depending on the topography and land use of cities, and based on this, the medium- and long-term plan should be established. Therefore, this study analyzed the flow of cold air at night through the KLAM_21 model in Suwon-si, Gyeonggi-do, to prepare the basic data required to apply the wind corridors. As a result, it turned out that cold air of Suwon-si was mainly generated from Gwanggyo Mountain that is a large mountain area in the north, and flowed into the urbanization promotion area, and about three hours after sunset, cold air flowed into the downtown. By district, the depth, wind speed, and direction of the cold air layer were formed differently according to the characteristics of the topography and land use. In the areas where large forests were adjacent, the flow of cold air was active. There are three main wind corridors where cold air flows to the downtown of Suwon-si, all of which are formed around rivers. Especially, if the connection between rivers and the surrounding green areas is high, the effect of wind corridors is found to be significant. In order to utilize the wind corridors of Suwon-si, based on the results of this study, it is necessary to make climate maps through actual survey and complex analysis of cold air flow and establish mid-to-long-term plans for the conservation and expansion of major wind corridors.

A Study on the Characteristics of Jobs in Academic Libraries According to Different Generations (대학도서관 업무의 시대별 변천에 따른 특성 연구)

  • Cho, Chul-Hyun
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.26 no.1
    • /
    • pp.135-170
    • /
    • 2015
  • This study aimed to investigate the transition of academic libraries' jobs by developing a model based on a shift of library generations including Library 1.0, Library 2.0, and Library 3.0 corresponding to the shift of web generations and to explore generational characteristics of library duties as well. The research used three phases of procedure: literature review about different library generations; job analyses for academic libraries in South Korea and the U.S.A.; the Delphi technique in tree sequential order. The research findings were as follows. First of all, there were 170 duties that continued from Library 1.0 to Library 3.0. There were 58 duties which continued from Library 2.0 to Library 3.0 whereas three duties that continued from Library 1.0 to Library 2.0. In addition, three distinctive duties existed only in Library 1.0 whereas one unique duty was only in Library 2.0. Library 3.0 generated 25 new duties. Secondly, considering general characteristics which cover specific parts of individual duties, there was a significant increase in importance, difficulty, and frequency of library administration throughout the three generations. In terms of importance, difficulty, and frequency of collection development and management, there was a significant increase only from Library 2.0 to Library 3.0. Considering information organization, there was a significant decrease in importance from Library 1.0 to Library 2.0. In addition, there was a significant decrease in frequency and there was no significant difference in difficulty throughout the three generations. In the case of information service, while there was a significant increase in importance among three generations, there was a significant increase in difficulty only from Library 1.0 to Library 2.0. However, there was no generational difference in frequency. With the respect of information system development and management, there was a significant increase in importance and frequency throughout the three generations, but there was no significant difference in difficulty among three generations.

Air Temperature Modification of an Urban Neighborhood Park in Summer - Hyowon Park, Suwon-si, Gyeonggi-do- (여름철 도시근린공원의 기온저감 효과 - 경기도 수원시 효원공원 -)

  • Park, Sookuk;Jo, Sangman;Hyun, Cheolji;Kong, Hak-Yang;Kim, Seunghyun;Shin, Youngkyu
    • Journal of Environmental Science International
    • /
    • v.26 no.9
    • /
    • pp.1057-1072
    • /
    • 2017
  • In order to investigate the effect of air temperature reduction on an urban neighborhood park, air temperature data from five inside locations (forest, pine tree, lawn, brick and pergola) depending on surface types and three outside locations (Suwon, Maetan and Kwonsun) depending on urban forms were collected during the summer 2016 and compared. The forest location had the lowest mean air temperature amongst all locations sampled, though the mean difference between this and the other four locations in the park was relatively small ($0.2-0.5^{\circ}C$). In the daytime, the greatest mean difference between the forest location and the two locations exposed to direct beam solar radiation (brick and lawn) was $0.5-0.8^{\circ}C$ (Max. $1.6-2.1^{\circ}C$). In the nighttime, the mean difference between the forest location and the other four locations in the park was small, though differences between the forest location and locations with grass cover (pine tree and lawn) reached a maximum of $0.9-1.7^{\circ}C$. Comparing air temperature between sunny and shaded locations, the shaded locations showed a maximum of $1.5^{\circ}C$ lower temperature in the daytime and $0.7^{\circ}C$ higher in the nighttime. Comparing the air temperature of the forest location with those of the residential (Kwonsun) and apartment (Maetan) locations, the mean air temperature difference was $0.8-1.0^{\circ}C$, higher than those measured between the forest location and the other park locations. The temperatures measured in the forest location were mean $0.9-1.3^{\circ}C$ (Max. $2.0-3.9^{\circ}C$) lower in the daytime than for the residential and apartment locations and mean $0.4-1.0^{\circ}C$ (Max. $1.3-3.1^{\circ}C$) lower in the nighttime. During the hottest period of each month, the difference was greater than the mean monthly differences, with temperatures in the residential and apartment locations mean $1.0-1.6^{\circ}C$ higher than those measured in the forest location. The effect of air temperature reduction on sampling locations within the park and a relatively high thermal environment on the urban sampling locations was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with a high sky view factor and surface types with high evapotranspiration potential (e.g. grass) showed the maximum air temperature reduction. In the urban areas outside the park, the low-rise building area, with a high sky view factor, showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, while in the nighttime the area with high-rise buildings, and hence a low sky view factor, showed high air temperature due to the effect of terrestrial (longwave) radiation emitted by surrounding high-rise building surfaces. The effect of air temperature reduction on the park with a high thermal environment in the city was clearly evident in the daytime, and the shading effect of trees in the forest location must be most effective. In the nighttime, areas with high sky view factor and surface types (e.g., grass) with evapotranspiration effect showed maximum air temperature reduction. In the urban areas outside the park, the high sky view factor area (low-rise building area) showed high air temperature due to the effect of solar (shortwave) radiation during the daytime, but in the nighttime the low sky view factor area (high-rise building area) showed high air temperature due to the effect of terrestrial (longwave) radiation emitted surrounding high-rise building surfaces.

Value of Information Technology Outsourcing: An Empirical Analysis of Korean Industries (IT 아웃소싱의 가치에 관한 연구: 한국 산업에 대한 실증분석)

  • Han, Kun-Soo;Lee, Kang-Bae
    • Asia pacific journal of information systems
    • /
    • v.20 no.3
    • /
    • pp.115-137
    • /
    • 2010
  • Information technology (IT) outsourcing, the use of a third-party vendor to provide IT services, started in the late 1980s and early 1990s in Korea, and has increased rapidly since 2000. Recently, firms have increased their efforts to capture greater value from IT outsourcing. To date, there have been a large number of studies on IT outsourcing. Most prior studies on IT outsourcing have focused on outsourcing practices and decisions, and little attention has been paid to objectively measuring the value of IT outsourcing. In addition, studies that examined the performance of IT outsourcing have mainly relied on anecdotal evidence or practitioners' perceptions. Our study examines the contribution of IT outsourcing to economic growth in Korean industries over the 1990 to 2007 period, using a production function framework and a panel data set for 54 industries constructed from input-output tables, fixed-capital formation tables, and employment tables. Based on the framework and estimation procedures that Han, Kauffman and Nault (2010) used to examine the economic impact of IT outsourcing in U.S. industries, we evaluate the impact of IT outsourcing on output and productivity in Korean industries. Because IT outsourcing started to grow at a significantly more rapid pace in 2000, we compare the impact of IT outsourcing in pre- and post-2000 periods. Our industry-level panel data cover a large proportion of Korean economy-54 out of 58 Korean industries. This allows us greater opportunity to assess the impacts of IT outsourcing on objective performance measures, such as output and productivity. Using IT outsourcing and IT capital as our primary independent variables, we employ an extended Cobb-Douglas production function in which both variables are treated as factor inputs. We also derive and estimate a labor productivity equation to assess the impact of our IT variables on labor productivity. We use data from seven years (1990, 1993, 2000, 2003, 2005, 2006, and 2007) for which both input-output tables and fixed-capital formation tables are available. Combining the input-output tables and fixed-capital formation tables resulted in 54 industries. IT outsourcing is measured as the value of computer-related services purchased by each industry in a given year. All the variables have been converted to 2000 Korean Won using GDP deflators. To calculate labor hours, we use the average work hours for each sector provided by the OECD. To effectively control for heteroskedasticity and autocorrelation present in our dataset, we use the feasible generalized least squares (FGLS) procedures. Because the AR1 process may be industry-specific (i.e., panel-specific), we consider both common AR1 and panel-specific AR1 (PSAR1) processes in our estimations. We also include year dummies to control for year-specific effects common across industries, and sector dummies (as defined in the GDP deflator) to control for time-invariant sector-specific effects. Based on the full sample of 378 observations, we find that a 1% increase in IT outsourcing is associated with a 0.012~0.014% increase in gross output and a 1% increase in IT capital is associated with a 0.024~0.027% increase in gross output. To compare the contribution of IT outsourcing relative to that of IT capital, we examined gross marginal product (GMP). The average GMP of IT outsourcing was 6.423, which is substantially greater than that of IT capital at 2.093. This indicates that on average if an industry invests KRW 1 millon, it can increase its output by KRW 6.4 million. In terms of the contribution to labor productivity, we find that a 1% increase in IT outsourcing is associated with a 0.009~0.01% increase in labor productivity while a 1% increase in IT capital is associated with a 0.024~0.025% increase in labor productivity. Overall, our results indicate that IT outsourcing has made positive and economically meaningful contributions to output and productivity in Korean industries over the 1990 to 2007 period. The average GMP of IT outsourcing we report about Korean industries is 1.44 times greater than that in U.S. industries reported in Han et al. (2010). Further, we find that the contribution of IT outsourcing has been significantly greater in the 2000~2007 period during which the growth of IT outsourcing accelerated. Our study provides implication for policymakers and managers. First, our results suggest that Korean industries can capture further benefits by increasing investments in IT outsourcing. Second, our analyses and results provide a basis for managers to assess the impact of investments in IT outsourcing and IT capital in an objective and quantitative manner. Building on our study, future research should examine the impact of IT outsourcing at a more detailed industry level and the firm level.

A Localized Secular Variation Model of the Geomagnetic Field Over Northeast Asia Region between 1997 to 2011 (지역화된 동북아시아지역의 지구자기장 영년변화 모델: 1997-2011)

  • Kim, Hyung Rae
    • Economic and Environmental Geology
    • /
    • v.48 no.1
    • /
    • pp.51-63
    • /
    • 2015
  • I produced a secular variation model of geomagnetic field by using the magnetic component data from four geomagnetic observatories located in Northeast Asia during the years between 1997 and 2011. The Earth's magnetic field varies with time and location due to the dynamics of fluid outer core and the magnetic observatories on the surface measure in time series. To adequately represent the magnetic field or secular variations of the Earth, a spatio-temporal model is required. In making a global model, satellite observations as well as limited observatory data are necessary to cover the regions and time intervals. However, you need a considerable work and time to process a huge amount of the dataset with complicated signal separation procedures. When you update the model, the same amount of chores is demanded. Besides, the global model might be affected by the measurement errors of each observatory that are biased and the processing errors in satellite data so that the accuracy of the model would be degraded. In this study, as considered these problems, I introduced a localized method in modeling secular variation of the Earth's magnetic field over Northeast Asia region. Secular variation data from three Japanese observatories and one Chinese observatory that are all in the INTERMAGNET are implemented in the model valid between 1997 to 2011 with the interval of 6 months. With the resulting model, I compared with the global model called CHAOS-4, which includes the main, secular variation and secular acceleration models between 1997 to 2013 by using the three satellites' databases and INTERMAGNET observatory data. Also, the geomagnetic 'jerk' which is known as a sudden change in the time derivatives of the main field of the Earth, was discussed from the localized secular acceleration coefficients derived from spline models.

Does Home Oxygen Therapy Slow Down the Progression of Chronic Obstructive Pulmonary Diseases?

  • Han, Kyu-Tae;Kim, Sun Jung;Park, Eun-Cheol;Yoo, Ki-Bong;Kwon, Jeoung A;Kim, Tae Hyun
    • Journal of Hospice and Palliative Care
    • /
    • v.18 no.2
    • /
    • pp.128-135
    • /
    • 2015
  • Purpose: As the National Health Insurance Service (NHIS) began to cover home oxygen therapy (HOT) services from 2006, it is expected that the new services have contributed to overall positive outcome of patients with chronic obstructive pulmonary disease (COPD). We examined whether the usage of HOT has helped slow down the progression of COPD. Methods: We examined hospital claim data (N=10,798) of COPD inpatients who were treated in 2007~2012. We performed ${\chi}^2$ tests to analyze the differences in the changes to respiratory impairment grades. Multiple logistic regression analysis was used to identify factors that are associated with the use of HOT. Finally, a generalized linear mixed model was used to examine association between the HOT treatment and changes to respiratory impairment grades. Results: A total of 2,490 patients had grade 1 respiratory impairment, and patients with grades 2 or 3 totaled 8,308. The OR for use of HOT was lower in grade 3 patients than others (OR: 0.33, 95% CI: 0.30~0.37). The maintenance/mitigation in all grades, those who used HOT had a higher OR than non-users (OR: 1.41, 95% CI: 1.23~1.61). Conclusion: HOT was effective in maintaining or mitigating the respiratory impairment in COPD patients.