• 제목/요약/키워드: coupling method

검색결과 2,400건 처리시간 0.158초

Seismic performance and design method of PRC coupling beam-hybrid coupled shear wall system

  • Tian, Jianbo;Wang, Youchun;Jian, Zheng;Li, Shen;Liu, Yunhe
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.83-96
    • /
    • 2019
  • The seismic behavior of PRC coupling beam-hybrid coupled shear wall system is analyzed by using the finite element software ABAQUS. The stress distribution of steel plate, reinforcing bar in coupling beam, reinforcing bar in slab and concrete is investigated. Meanwhile, the plastic hinges developing law of this hybrid coupled shear wall system is also studied. Further, the effect of coupling ratio, section dimensions of coupling beam, aspect ratio of single shear wall, total height of structure and the role of slab on the seismic behavior of the new structural system. A fitting formula of plate characteristic values for PRC coupling beams based on different displacement requirements is proposed through the experimental date regression analysis of PRC coupling beams at home and abroad. The seismic behavior control method for PRC coupling beam-hybrid coupled shear wall system is proposed based on the continuous connection method and through controlling the coupling ratio, the roof displacement, story drift angle of hybrid coupled shear wall system, displacement ductility of coupling beam.

반경 방향으로 자화된 Tubular 타입 자기 커플링의 특성 해석 (Characteristics Analysis of Radially Magnetized Tubular type Magnetic Coupling)

  • 김창우;정경훈;최장영
    • 전기학회논문지
    • /
    • 제64권11호
    • /
    • pp.1551-1557
    • /
    • 2015
  • Magnetic coupling is used where required high reliability. because magnetic coupling's durability is stronger than mechanical coupling's durability. This paper shows the characteristics of radially magnetized tubular type magnetic coupling by using Analytical method such as space harmonic method. Analytical method was used, to find force characteristics. First, on the basis of the magnetic vector potential and two-dimensional(2-D) polar-coordinate system, the magnetic field solutions of the radially magnetized permanent magnet are obtained. And we obtain the analytical solutions for the flux density produced by permanent magnet. Finally, we can calculate the force by using the Maxwell stress tensor. And then, Finite element method(FEM) is used to validate force characteristics.

FEM과 BEM의 혼합적용에 의한 정상자계의 해석에 관한 연구 (A Study on the Analysis of Steady Magnetic Fields by the Coupling of FEM and BEM)

  • 임달호;김찬오
    • 대한전기학회논문지
    • /
    • 제34권7호
    • /
    • pp.276-282
    • /
    • 1985
  • This study is concerned with the analysis of two-dimensional steady magnetic fields by the coupling of FEM and BEM. FEM(Finite Element Method)is most widely used as a method of numerical analysis and BEM (Boundary Element Method)is a newest method for it. And the results from this coupling method are compared and discussed with those of FEM only. Consequently, it is shown that to obtain the same accuracy of results the coupling method requires less calculating time and dimension than the FEM.

  • PDF

교차 결합 현상을 고려한 매입형 영구자석 전동기의 인덕턴스 특성 해석 (Inductance Analysis of Interior Permanent Magnet Synchronous Motor Considering Cross-Coupling Effect)

  • 곽상엽;김재광;정현교;이상엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권4호
    • /
    • pp.189-195
    • /
    • 2006
  • In this paper, the inductance characteristics of interior permanent magnet synchronous motor (IPMSM) considering cross-coupling effect is analyzed. It is known that the IPMSM has it's operating point at the saturated region. So the cross-coupling effect exists, therefore cross-coupling inductance exists. With the application of Fixed Permeability Method (FPM), we can obtain more exact inductance characteristics of IPMSM. In this paper, a novel method based on the FPM is proposed, which can consider the cross-coupling effect. And the cross-coupling inductance which is the analysis result is shown. Finally, the validity of proposed method is verified by the comparison with the experimental result.

Halbach 배열 자화를 갖는 Tubular 타입 커플링의 힘 특성 해석 (Force Characteristics Analysis of Halbach Array Magnetized Tubular-Type Magnetic Coupling)

  • 김창우;김정만;최장영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.762-763
    • /
    • 2015
  • Magnetic coupling is used where required high reliability. because magnetic coupling's durability is stronger than mechanical coupling's durability. This paper shows the force characteristics of halbach array magnetized tubular type magnetic coupling using Analytical method. Analytical method was used, to find force characteristics. Finite element method (FEM) is used to validate force characteristics.

  • PDF

무한탄성영역 해석을 위한 EFG와 BEM의 새로운 결함기법 개발 (A new coupling method of Element-Free Galerkin Method and Boundary Element Method for infinite domain problems in elasticity)

  • 이상호;김명원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.575-582
    • /
    • 2002
  • A new coupling method of Element-Free Galerkin Method(EFGM) and Boundary Element Method(BEM) using the domain decomposition method is presented in this paper. This proposed methodology is that the problem domain is decomposed into sub-domains being modeled by the EFGM and BEM respectively and the respective EFGM and BEM domains share a partially overlapped region over an entire domain. Then, the each sub-domain is separately computed and the variables on common region are iteratively updated until converging. It is an important note that in the developed coupling method, there is no need to combine the coefficient matrices of EFGM and BEM sub-domains, in contrast with the other conventional coupling methods. In the first part of this paper, a theory of EFGM and BEM is summarized, and then a brief introduction of domain decomposition method is described. Then, a new coupling method is presented. Also, patch test and Some numerical examples are studied to verify stability, accuracy and efficiency of the proposed method, in which numerical performance of the method is compared with that of conventional method such as EFGM-BEM variational coupling method, EFGM and BEM.

  • PDF

Comparative analyses of a shield building subjected to a large commercial aircraft impact between decoupling method and coupling method

  • Han, Pengfei;Liu, Jingbo;Fei, Bigang
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.326-342
    • /
    • 2022
  • Comparative analyses of a shield building subjected to a large commercial aircraft impact between decoupling method and coupling method are performed in this paper. The decoupling method is applying impact force time-history curves on impact area of the shield building to study impact damage effects on structure. The coupling method is using a model including aircraft and shield building to perform simulation of the entire impact process. Impact force time-history curves of the fuselage, wing and engine and their total impact force time-history curve are obtained by the entire aircraft normally impacting the rigid wall. Taking aircraft structure and impact progress into account some loading areas are determined to perform some comparative analyses between decoupling method and coupling method, the calculation results including displacement, plastic strain of concrete and stress of steel plate in impact area are given. If the loading area is determined unreasonably, it will be difficult to assess impact damage of impact area even though the accurate impact force of each part of aircraft obtained already. The coupling method presented at last in this paper can more reasonably evaluate the dynamic response of the shield building than the decoupling methods used in the current nuclear engineering design.

Weak Coupling Method를 이용한 계통 축약 (A Network Reduction using Weak Coupling Method)

  • 이한민;노규민;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1067-1069
    • /
    • 1999
  • This paper presents a network reduction using weak coupling method. Weak coupling method of identifying coherent generator groups are proposed. The partitioning technique used in this paper is based on a property of sparse matrix factorization. When a matrix has been factorized, a system is divided into study area, boundary buses and external area. A reduction process for external system starts with the load bus elimination and coherent generator aggregation. An identification of coherent generator group, network partitioning and network reduction are presented.

  • PDF

AWGN 채널환경에서 Direct-Conversion 수신기의 성능분석에 관한 연구 (A Study on a Performance Analysis of Direct-Conversion Receiver In Additive White Gaussian Noise Channel)

  • 조형래;김철성;박성진
    • 한국정보통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.668-675
    • /
    • 2001
  • 최근, 상업적인 pcs시스템은 매우 발전되어 있으며, 결국 차세대 이동통신은 멀티미디어 서비스를 제공하는 IMT-2000에 의해 실현될 것이다. 그러므로 , 새로운 형태의 수신 시스템 연구가 활발히 진행되고 있고, 이중하나가 Direct conversion 방식이다 Direct conversion은 차세대 이동통신 시스템에 필요한 저전력, 소형, MMIC, 저가에 적합한 방식이다. 이 시스템을 사용할 경우 DC-offset의 문제가 발생하게 된다. DC-offset은 시스템에서 주파수 합성기의 누설신호에 의해 원하는 신호의 증폭을 억압한다. 본 논문에서 DC-offset을 제거하는 방법에 대해 고려한다. DC-offset의 제거법에는 AC-coupling, 대용량 capacitor, DC-feedback loop, DC-free coding의 4가지 방법이 있다. 이중에서 AC-coupling법은 가장 간단하며, DC-feedback법은 최고의 성능을 가진다. AC-coupling법과 DC-feedback법을 HP사의 ADS를 사용하여 시뮬레이션 하였다.

  • PDF

효소-항체의 결합 및 효소면역측정 방법의 연구 (Study on Antibody-enzyme Coupling and Enzyme Immunoassay Methods)

  • 장선일
    • 동의생리병리학회지
    • /
    • 제18권3호
    • /
    • pp.874-879
    • /
    • 2004
  • Alakaline phosphatase (ALP)- or horseradish peroxidase (HRP)-antibody conjugate was used frequently on the immunological detection methods such as enzyme-linked immunosobent assay (ELISA), immunobolt, immunohistochemistry. The classical enzyme-antibody coupling method by one-step (direction) injection of glutaraldehyde bring into being disadvantage such as low sensitivity of antigen detection because of homopolymers. This study was modified with the dialysis glutaraldehyde method to provide simple coupling through E-amino residues present in most protein. The dialysis glutaraldehyde coupling effects were better than the classical one-step glutaraldehyde injection in antigen detection of ELISA and immunobolt. Optimal dose of the dialysis glutaraldehyde solution was 0.10-0.25 %. This results suggest that the dialysis glutaraldehyde coupling method can readily applied to antigen detection of in vitro and in vivo.