• Title/Summary/Keyword: coupling length

Search Result 339, Processing Time 0.026 seconds

Improvement of extinction ratio of polarization independent very short vertical directional couplers with the double-sided deep-ridge waveguide structure (편광에 관계없이 매우 짧은 결합길이를 가지는 Double-Sided Deep-Ridge 도파관 구조 수직 방향성 결합기의 소멸비 향상)

  • 정병민;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.12-16
    • /
    • 2004
  • We show that the extinction ratio is improved using slight asymmetry in two core refractive indices of polarization independent very short vertical directional couplers with the double-sided deep-ridge (DSDR) waveguide structure. The optimum asymmetry with the maximum extinction ratio and the tolerance of the refractive index of core with the extinction ratio larger 1ha]1 30 ㏈ increase as the thickness of inner cladding layer and the two cores decrease due to the increase of the coupling strength between the two cores. Also, the device length and the tolerance of the device length with the extinction ratio larger than 30 ㏈ decrease as the thickness of the inner cladding layer and the two cores decrease due to the increase of the coupling strength between the two cores. We show that polarization independent vertical directional couplers with the DSDR waveguide structure with the device length less than 100 ${\mu}{\textrm}{m}$ and the extinction ratio larger than 30 ㏈ could be implemented.

The Damage of Microcontroller Devices due to Coupling Effects under High Power Electromagnetic Wave by Magnetron (고출력 전자기파의 커플링 효과에 의한 마이크로 컨트롤러의 손상)

  • Hong, Joo-Il;Hwang, Sun-Mook;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2263-2268
    • /
    • 2008
  • We investigated the malfunction and destruction characteristics of microcontroller devices under high power electromagnetic(HPEM) wave by magnetron. HPEM was rated at a microwave output of 0 to 1,000 W, at a frequency of 2,450${\pm}$50 MHz and was radiated from the open-ended standard rectangular waveguide(WR-340) to free space. The influence of different reset-, clock-, data-, and power supply-line lengths has been tested. The variation of the line length was done with flat cables. The susceptibility of the tested microcontroller devices was in general much influenced by clock-, reset-, and power supply-line length, little influenced by data-line length. Further the line length was increased, the malfunction threshold was decreased as expected, because more energy couples to the devices. The surfaces of the destroyed microcontroller devices were removed and the chip conditions were investigated with microscope. The microscopic analysis of the damaged devices showed component and bondwire destructions such as breakthroughs and melting due to thermal effects. The obtained results are expected to provide fundamental data for interpreting the combined mechanism of microcontroller devices in an intentional microwave environment.

An Experimental Study on Steel Plate Coupling Beam (철골 플레이트 커플링 보의 실험적 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.301-304
    • /
    • 2008
  • This paper presented an structural efficiency of steel coupling beam jointed single plate shear connections with seat and top angle. Parameters for the test specimens were are seat and top angle, reinforcing of concrete, embedded length, section loss. Steel coupling beam with angle showed excellent strength, stiffness, energy dissipation capacity. The specimen with no reinforcement around the embedded steel plate showed slightly low deformation capacity because of early failure in the precast concrete walls. However, the specimen with reinforcement around the embedded steel plate showed good deformation capacity. Deformation capacity was not decrease despite short embedded length. The specimen with section loss showed excellent deformation capacity. Because shear strength of steel coupling beam was lesser than of connections. These results showed that for workability and cost efficiency, the proposed system is promising for one of steel coupling beam.

  • PDF

Vertical Coupling of Polymeric Double-Layered Waveguides Using a Stepped MMI Coupler

  • Lee, Jong-Moo;Ahn, Joon-Tae;Cho, Doo-Hee;Ju, Jung-Jin;Lee, Myung-Hyun;Kim, Kyong-Hon
    • ETRI Journal
    • /
    • v.25 no.2
    • /
    • pp.81-88
    • /
    • 2003
  • We designed a multimode interference (MMI) coupler to use in vertical coupling of double layered polymeric waveguides and analyzed the coupling characteristics by comparing our experimental and simulation results. We found that our proposed new structure, a stepped MMI coupler, is effective in vertical coupling between waveguide layers with a short length of MMI and has a high tolerance for the variation in the structure of an MMI coupler that can be induced as errors in the fabrication process.

  • PDF

Vibration Analysis of Combined Cylindrical Shells with an Annular Plate (환원판이 결합된 원통셸의 진동해석)

  • Kim, Young-Wann;Chung, Kang
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.767-776
    • /
    • 2003
  • The theoretical method is developed to Investigate the nitration characteristics of the combined cylindrical shells with an annular plate joined to the shell at any arbitrary axial position. The structural coupling between shell and plate is simulated using two types of artificial springs a translational spring is introduced for translational coupling and a rotational spring is used for rotational coupling. The springs are continuously distributed along circumferential direction. Using the Rayleigh-Ritz method the natural frequencies and mode shapes of the combined shell with an annular plate examine. The effect of Inner-to-outer radius ratio, axial position of annular plate and length-to-radius ratio of shell on vibration characteristics of combined cylindrical shells is studied. The theoretical results are verified by comparison with FEM results.

Calculation of the coupling coefficient for trapezoidal gratings using the ray optics technique (기하광학 방법을 이용한 사다리꼴 회절격자의 결합계수 계산)

  • 조성찬;김부균
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.7
    • /
    • pp.97-104
    • /
    • 1997
  • Using the ray optics technique, we derive the analytic expressions of TE mode coupling coefficient for five-layer distributed feedback (DFB) structure devices. We compare the coupling coefficient calculated by the ray optics technique with those calulated by the extended additional layer method (EALM) which may be a most accurate method of calculating the coupling coefficient. The difference between the results of the ray optics technique and those of the EALM is small for most cases of grating depth and forms being practically made. In the case of rectangular gratings, the difference increases as the duty cycle of graing deviates from 0.5. In the case of the trapezoidal grating, the difference increases as the ratio of the top to the period of grating deviates from 0.5 and as the length of the top becomes longer than that of the base. The difference of theree-layer DFB structures is smaller than that of five-layer DFB structures.

  • PDF

Temperature Stability of Electro-mechanical Coupling Factors of PZT Ceramics (PZT 세라믹스의 전기기계결합계수 온도 안정성에 관한 연구)

  • Lee, Gae-Myoung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.1
    • /
    • pp.27-32
    • /
    • 2014
  • In this paper, PZT piezoelectric ceramic specimens with 4 compositions (Zr/Ti=50/50, 53/47, 56/44, 58/42) in $Pb(Zr,Ti)O_3$ system were fabricated. We studied effects of poling strength and thermal aging on the temperature characteristics of eletromechanical coupling factor k31 of the specimens, which were poled with the DC electric fields, 1.5, 2.5 and 3.5 kV/mm respectively and thermally aged for an hour at $200^{\circ}C$. The eletromechanical coupling factor k31 of the specimen with the composition Zr/Ti= 53/47, nearest to the morphotropic phase boundary decreased the most greatly, irrelevant to the intensity of poling field, due to 1st thermal aging. And the temperature coefficient of eletromechanical coupling factor k31 was (-) in the tetragonal phase composition and (+) in the rhombohedral phase composition, which is reverse in the temperature coefficient of resonance frequency. It is interesting that eletromechanical coupling factor k31 of PZT ceramics is shown to be able to increase as temperature increase in the interval $-20{\sim}80^{\circ}C$.

The Effect of Mutual Coupling between Current and Potential Test Leads on Ground Impedance (전류 및 전위 측정선간 상호유도가 접지임피던스에 미치는 영향)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1223-1228
    • /
    • 2008
  • While a high frequency source is used for measuring the ground impedance, there are several factors having an effect on the measured value. A primary factor of the measurement error is the ac mutual coupling between current and potential test leads. The mutual coupling causes the test current to induce a voltage into the potential test lead that adds to the actual ground potential rise and produces a significant measurement error as the length of the test leads paralleled is prolonged. In order to avoid the mutual coupling, it is recommended that the ground impedance be measured by angled arrangement of test leads. The mutual impedance due to the inductive coupling with an angle of $90^{\circ}$ was calculated at $0^{\circ}$ by Campbell/Foster Method. With an angle of $180^{\circ}$, the mutual impedance was calculated large value enough to introduce a fairly large margin of error, however, the measured value of ground impedance was close to the value at $90^{\circ}$.

Behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 2: Evaluation of theoretical strength

  • Zhu, Y.;Su, R.K.L.
    • Structural Engineering and Mechanics
    • /
    • v.34 no.5
    • /
    • pp.563-580
    • /
    • 2010
  • Composite beams using bolts to attach steel plates to the side faces of existing reinforced concrete (RC) coupling beams can enhance both their strength and deformability. The behavior of those composite beams differs substantially from the behavior of typical composite beams made up of steel beams and concrete slabs. The former are subjected to longitudinal, vertical and rotational slips, while the latter only involve longitudinal slip. In this study, a mixed analysis method was adopted to develop the fundamental equations for accurate prediction of the load-carrying capacity of steel plate strengthened RC coupling beams. Then, a rigid plastic analysis technique was used to cope with the full composite effect of the bolt group connections. Two theoretical models for the determination of the strength of medium-length plate strengthened coupling beams based on mixed analysis and rigid plastic methods are presented. The strength of the strengthened coupling beams is derived. The vertical and longitudinal slips of the steel plates and the shear strength of the anchor-bolt connection group is considered. The theoretical models are validated by the available experimental results presented in a companion paper. The strength of the specimens predicted from the mixed analysis model is found to be in good agreement with that from the experimental results.

Development of High-speed Shaft Coupling for 6 MW Class Offshore Wind Turbine (6 MW급 해상풍력발전기용 고속축커플링 개발)

  • Park, Soo-Keun;Lee, Hyoung-Woo
    • Journal of Wind Energy
    • /
    • v.10 no.4
    • /
    • pp.20-27
    • /
    • 2019
  • High-speed shaft coupling in a wind power system transmits power and absorbs variations in length and spindle dislocation between the gearbox and generator. Furthermore, the coupling has an insulation function that prevents electrical corrosion caused by the flow of the generator's current into the gearbox and prevents overload resulting from sudden power failure from being transferred to the gearbox. Its design, functions, and part verification are described in the IEC61400 and GL Guidelines, which specify that the part must have a durability life of 20 years or longer under distance variation and axial misalignment between the gearbox and the generator. This study presents the design of a high-speed coupling through composite stiffness calculation, structural analysis, and comparative analysis of test and theory to identify the characteristics of high-speed coupling for a large-capacity 6 MW wind power generator. A prototype was fabricated by optimizing the manufacturing process for each part based on the design, and the reliability of the fabricated prototype was verified by evaluating the performance of the target quantitative evaluation items.