• Title/Summary/Keyword: coupling capacitor

Search Result 121, Processing Time 0.026 seconds

Review of the tracebility of ERA PD measuring system in test laboratory (시험소 부분방전 측정시스템(ERA)의 소급성검토)

  • Heo, J.C.;Kang, Y.S.;Kim, W.Y.;Oh, C.S.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1969-1971
    • /
    • 2004
  • For evaluation of partial discharge performances of electrical power appratus such as Insulator, circuit breaker and transformer and so on, Partial discharge measuring system(ERA) consisted of PD detector including amplifier, coupling capacitor, PD calibrator and voltage divider are used PD measuring system is very important factor which affect the test result and show reliability of test result in test laboratory, In this paper, we describe tracebility and uncertainty of PD measuring system in test laboratory based on IEC 60270.

  • PDF

Miniaturization of Dual-Band PIFA for Wireless LAN Communication

  • Liu, Yang;Lee, Jaeseok;Jeon, Sinhyung;Jung, Kyung-Young;Kim, Hyunghoon;Kim, Hyeongdong
    • ETRI Journal
    • /
    • v.35 no.3
    • /
    • pp.530-533
    • /
    • 2013
  • In this letter, a simple method for reducing the size of a dual-band planar inverted-F antenna (PIFA) is described. This method is based on a coupling capacitor connected in parallel to the PIFA feed conductor. The proposed antenna occupies a small ground clearance of $10mm{\times}5mm$ and is able to provide -10-dB impedance bandwidths of 120 MHz and 760 MHz for 2.45-GHz and 5.5-GHz wireless local area network applications, respectively. The measured antenna efficiencies are 71.8% and 73.6%, averaged over the 2.45-GHz and 5.5-GHz frequency bands, respectively.

Phase-Shifter for Real-Time Control of Transmission System (송전계통의 실시간 제어를 위한 위상변이기)

  • Han, Hyung-Moon;Chang, Byong-Kun
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.432-434
    • /
    • 1994
  • This paper describes a phase-shifter which can flexibly adjust the active and reactive power flow through an ac transmission line. The phase-shifter has two voltage-source converters sharing an energy storage capacitor. The magnitude of the injected voltage is controlled by the converter I connected in parallel with the sending terminal, while that of phase angle by the converter II in series with the line through the coupling transformer. In order to analyze the whole system operation, an equivalent circuit model was developed and verified by a computer simulation with EMTP code.

  • PDF

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated high frequency signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lim, Byung-Ho;Kim, Chul-Hwan;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1376-1378
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range In this respect, this paper describes the basis of a Protection technique for transmission lines which utilises high-frequency components. Fault-generated signals caused by post-fault and the signal derived from stack tuner is connected to the coupling capacitor of CVT. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the Protected zone, and to discriminate the fault type on transmission line.

  • PDF

Propagation Characteristics of Acoustic Signals Produced by Partial Discharges in an Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Park, Dae-Won;Cha, Sang-Wook;Cho, Hyang-Eun;Kim, Dong-Geon;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.188-188
    • /
    • 2011
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. We fabricated a decoupler and an amplifier to measure acoustic signals produced by PD. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz~1.6 MHz. After a comparative calibration by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil as a function of distance.

  • PDF

Design of BPF for WLAN with Heterogeneous LTCC Materials (이종적층 LTCC 기술을 이용한 WLAN용 대역통과 필터 설계)

  • Ko, Jeong-Ho;Yook, Jong-Gwan;Park, Han-Kyu;Kim, Jun-Chul;Lee, Young-Shin
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.188-192
    • /
    • 2003
  • A multilayer two-stage LC bandpass filter using low-temperature cofired-ceramic (LTCC) is proposed in this paper. The proposed bandpass filter is composed of two ceramic substrates with different dielectric constant instead of single ceramic material from top to bottom layer. The bandpass filter size is $2.0 mm{\times}1.2 mm{\times}0.8 mm$. Positioning of attenuation polefrequency, importance parameter for a performance of filter, is discussed using even-odd mode analysis by tuned capacitance of coupling capacitor and those results is implemented to LTCC filter circuit. Measured filter performances show that the insertion losses are -4.5dB, -4.1dB at 2.45GHz, 2.75GHz and the return losses are -8.5dB, 8.7dB.

  • PDF

Development of On-Line Monitoring System for Insulation Diagnosis of High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 상태진단을 위한 운전중 모니터링 시스템 개발)

  • Hwang, Don-Ha;Sim, Woo-Yong;Kim, Yong-Joo;Song, Sang-Ock;Ju, Yeung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1701-1703
    • /
    • 2002
  • This paper introduces a on-line monitoring system for insulation diagnosis of high-voltage motor stator windings. This system monitors the insulation condition of the stator winding with sensor, coupling capacitor. Partial discharge (PD) signals are able to be continuously measured and digitalized with a Peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. This system can communicate with the central monitoring system via RS-485 This paper introduces an economic solution for data acquisition of partial discharges.

  • PDF

A Study for Indirect Channel Noise Measurement in Powerline Communications (전력선 통신 채널의 간접 잡음 측정에 대한 방안 연구)

  • Son, Hyun-Il;Oh, Hui-Myoung;Lee, Jae-Jo;Lee, Won-Tae;Kim, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2611-2613
    • /
    • 2002
  • 본 논문에서는 전력선 통신 채널의 간접 잡음 측정에 대한 연구를 하였다. 주위 환경에 의한 Noise 및 여러 통신매체에 의한 방해전파에 의해 전력선 통신 채널은 송신 측의 고출력 요구와 가능한 전력선 통신의 대역폭이 감소하는 악화된 통신환경을 보여 준다. 이러한 Noise를 측정하는 방법은 Coupling Capacitor를 이용한 직접 측정 방식과 이동 측정 장치를 이용한 간접 측정 방식이 있다. 전자는 광범위한 측정지역과 측정장비의 설치 등에서의 번잡함으로 효과적인 Noise 측정이 어렵다. 본 논문에서는 두 가지 방식의 Noise 측정 결과의 비교 및 검토를 통해 이동 측정 장치를 이용한 방식의 장점과 보완할 점을 검토였으며, 특히 직접 측정 방식과의 결과 값의 차이를 보상할 수 있는 상관관계 분석의 필요성을 고찰하였다.

  • PDF

Propagation Characteristics of Acoustic Signals Produced by Partial Discharge in Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Kim, Sung-Wook;Park, Chan-Yong;Park, Dae-Won;Kil, Gyung-Suk;Rhyu, Keel-Soo
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.841-847
    • /
    • 2009
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. To measure small acoustic signals produced by PD, we fabricated an amplifier and simulated PD at a needle-plane electrode system set in insulation oil. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz$\sim$1.6 MHz. These are enough characteristics for the measurement of acoustic signals. After a comparative calibration experiment by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil.

  • PDF