• Title/Summary/Keyword: coupling

Search Result 7,576, Processing Time 0.043 seconds

Examination of Efficiency Based on Air Gap and Characteristic Impedance Variations for Magnetic Resonance Coupling Wireless Energy Transfer

  • Agcal, Ali;Bekiroglu, Nur;Ozcira, Selin
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • In this paper wireless power transmission system based on magnetic resonance coupling circuit was carried out. With the research objectives based on the mutual coupling model, mathematical expressions of optimal coupling coefficients are examined. Equivalent circuit parameters are calculated by Maxwell software, and the equivalent circuit was solved by Matlab software. The power transfer efficiency of the system was derived by using the electrical parameters of the equivalent circuit. System efficiency was analyzed depending on the different air gap values for various characteristic impedances. Hence, magnetic resonance coupling involves creating a resonance and transferring the power without radiating electromagnetic waves. As the air gap between the coils increased the coupling between the coils were weakened. The impedance of circuit varied as the air gap changed, affecting the power transfer efficiency.

Effect of capacitive coupling in superconducting coplanar waveguide resonator

  • Baek, Geonwoo;Kim, Bongkeon;Arif, Sara;Doh, Yong-Joo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.6-9
    • /
    • 2021
  • Superconducting coplanar waveguide (SCPW) resonators with high quality (Q) factor are widely used for developing quantum sensors and quantum information processors. Here we conducted numerical simulations of SCPW resonators to investigate the relationship between the Q factor and the coupling capacitance of the resonator. Varying the geometrical shape of both ends and coupling parameters of the SCPW resonator resulted in a change of the coupling capacitances and the Q factor as well. Our calculation results indicate that the performance of the SCPW resonator is highly sensitive to the capacitive coupling and searching for an optimal coupling condition would be crucial for developing high-performance SCPW resonator.

Improvements of Impact strength in Glass Fiber/Polypropylene Composite by Silane Coupling Agents (실란커플링제에 의한 유리섬유/폴리프로필렌 복합재료의 충격강도 증가에 관한 연구)

  • 정광보
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.43-47
    • /
    • 2001
  • Effect of coupling agent on the mechanical properties of PP/GF blend was investigated. The flexural modulus, Izod impact strength, elongation at yield and tensile strength were improved with using coupling agent. Mopological studies revealed that PP and GF were incompatible and addition of coupling agent was very effective to enhance the compatibility, result in mechanical properties.

  • PDF

A Study on the RF filter of Wireless LAN using Hairpin Resonator (Hairpin 공진기를 이용한 무선 LAN용 RF필터에 관한 연구)

  • 오태성;이영훈
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.424-428
    • /
    • 2000
  • In this paper, a MIC(Microwave Integrated Circuit) bandpass filter for wireless LAN(local area network) band is designed using hairpin resonators. The coupling between the hairpin resonators in the filter can be implemented with Y-Tpye coupling or X-Tpye coupling instead of conventional coupling in order to reduce the filter size. The filter with miniaturized hairpin resonator using parallel coupling is smaller in size by 50% more than that of a general hairpin filter

  • PDF

Force Characteristics Analysis of Halbach Array Magnetized Tubular-Type Magnetic Coupling (Halbach 배열 자화를 갖는 Tubular 타입 커플링의 힘 특성 해석)

  • Kim, Chang-Woo;Kim, Jeong-Man;Choi, Jang-Young
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.762-763
    • /
    • 2015
  • Magnetic coupling is used where required high reliability. because magnetic coupling's durability is stronger than mechanical coupling's durability. This paper shows the force characteristics of halbach array magnetized tubular type magnetic coupling using Analytical method. Analytical method was used, to find force characteristics. Finite element method (FEM) is used to validate force characteristics.

  • PDF

Synthesis of Dimeric Oligodeoxyribonucleotide (이합체성 올리고디옥시리보핵산의 합성)

  • Song, Jeong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1566-1571
    • /
    • 2007
  • Oligodeoxyribonucleotide bearing the di-acetylenic linkage has been prepared. Staring from 5-Iodo-2'-deoxyuridine(1), a four-step sequence, consisting of the Pd(0)-catalyzed Heck-type C-C coupling with acetylenic group, protection of 5'-hydroxy group, generation of acetylenic hydrogen, and Glaser oxidative coupling reaction leads to the dimeric oligodeoxyribonucleotide(5).

  • PDF

Effect of Aspect Ratio and Diagonal Reinforcement on Shear Performance of Concrete Coupling Beams Reinforced with High-Strength Steel Bars (세장비 및 대각철근 유무에 따른 고강도 철근보강 콘크리트 연결보의 전단성능)

  • Kim, Sun-Woo;Jang, Seok-Joon;Yun, Hyun-Do;Seo, Soo-Yeon;Chun, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2017
  • As per current seismic design codes, diagonally reinforced coupling beams are restricted to coupling beams having aspect ratio below 4. However, a grouped diagonally reinforcement detail makes distribution of steel bars in the beam much harder, furthermore it may result in poor construction quality. This paper describes the experimental results of concrete coupling beam reinforced with high-strength steel bars (SD500 & SD600 grades). In order to improve workability for fabricating coupling beams, a headed large diameter steel bar was used in this study. Two full-scale coupling beams were fabricated and tested with variables of reinforcement details and aspect ratio. To reflect real behavior characteristic of the beam coupling shear walls, a rigid steel frame system with linked joints was set on the reaction floor. As a test result, it was noted that cracking and yielding of reinforcement were initially progressed at the coupling beam-to-shear wall joint, and were progressed to the mid-span of the coupling beam, based on the steel strain and failure modes. It was found that the coupling beams have sufficient deformation capacity for drift ratio of shear wall corresponding to the design displacement in FEMA 450-1. In this study, the headed horizontal steel bar was also efficient for coupling beams to exhibit shear performance required by seismic design codes. For detailed design for coupling beam reinforced with high-strength steel, however, research about the effect of variable aspect ratios on the structural behavior of coupling beam is suggested.

Seismic Behavior of Slender Coupling Beams Constructed with High-Performance Fiber Reinforced Cementitious Composite (고성능 섬유 보강 시멘트 복합체(HPFRCC)를 적용한 세장한 연결보의 내진거동 평가)

  • Han, Sang Whan;Kwon, Hyun Wook;Shin, Myung Su;Lee, Ki Hak;Cho, Young Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.271-278
    • /
    • 2013
  • The hysteretic behavior of diagonal reinforced coupling beams is excellent during earthquakes. However, construction of the diagonal reinforced coupling beams is difficult due to complex reinforcement details required by current code procedures (ACI 318-11). Due to the detail requirement, reinforcement congestion and interference among transverse reinforcement always occur during construction field. When the aspect ratio of the beam is large, the interference of reinforcement becomes more serious. The objective of this paper is to simplify the reinforcement details of slender coupling beams by reducing transverse reinforcement around the beam perimeter. For this purpose, high- performance fiber reinforced cementitious composites are used for making coupling beams. Experiments were conducted using three specimens having aspect ratio 3.5. Test results showed that HPFRCC coupling beams with half the transverse reinforcement required by ACI 318-11 provided identical seismic capacities to the corresponding coupling beams having requirement satisfying the requirement specified in ACI 318-11.