• 제목/요약/키워드: coupled system

검색결과 3,200건 처리시간 0.123초

Aviation stability analysis with coupled system criterion of theoretical solutions

  • C.C. Hung;T. Nguyen
    • Coupled systems mechanics
    • /
    • 제12권3호
    • /
    • pp.221-239
    • /
    • 2023
  • In our research, we have proposed a solid solution for aviation analysis which can ensure the asymptotic stability of coupled nonlinear plants, according to the theoretical solutions and demonstrated method. Because this solution employed the scheme of specific novel theorem of control, the controllers are artificially combined by the parallel distribution computation to have a feasible solution given the random coupled systems with aviation stability analysis. Therefore, we empathize and manually derive the results which shows the utilized lemma and criterion are believed effective and efficient for aircraft structural analysis of composite and nonlinear scenarios. To be fair, the experiment by numerical computation and calculations were explained the perfectness of the methodology we provided in the research.

Formation of a Narrow Domain Wall Using Local Exchange Coupled System (국소적 교환상호작용을 이용한 좁은 자벽의 생성)

  • You, Chun-Yeol
    • Journal of the Korean Magnetics Society
    • /
    • 제15권4호
    • /
    • pp.221-225
    • /
    • 2005
  • Formation of a narrow magnetic domain wall is demonstrated by micromagnetics simulations. It is found that the domain wall width can be shrunk in a local exchange coupled system. The local exchange coupled system means that only a part of a ferromagnetic layer has an exchange coupling with another ferromagnetic layer. The system can be considered as two parts in the lateral dimensions: one is an exchange coupled region and another is a free region. Since the two regions have quite different local switching fields, the domain wall will be formed at the interface between the two regions at moderate field ranges.

Application of ROMS-NPZD Coupled Model for Seasonal Variability of Nutrient and Chlorophyll at Surface Layer in the Northwestern Pacific (ROMS-NPZD 접합모델을 이용한 한반도 주변해역의 표층 영양염 및 클로로필의 계절변동성)

  • Lee, Joon-ho;Kim, Tae-hoon;Moon, Jae-hong
    • Ocean and Polar Research
    • /
    • 제38권1호
    • /
    • pp.1-19
    • /
    • 2016
  • Recently, there has been a growing interest in physical-biological ocean-modeling systems by communities in the fields of science and business. In this paper, we present preliminary results from a coupled physical-biological model for the Northwestern Pacific marginal seas. The ocean circulation component is an implementation of the Regional Ocean Modeling System (ROMS), and the lower trophic level ecosystem component is a Nutrient-Phytoplankton-Zooplankton-Detritus (NPZD) model. The ROMS-NPZD coupled system, with a 25 km resolution, is forced by climatological atmospheric data and predicts the physical variables and concentrations of nitrate, phytoplankton, zooplankton, and detritus. Model results are compared with remote-sensed sea surface temperature and chlorophyll, and with climatological sea surface salinity and nitrate. Our model adequately reproduces the observed spatial distribution and seasonal variability of nitrate and chlorophyll concentrations as well as physical variables, showing a high correlation in the East Sea (ES) and Kuroshio/Oyashio Extension (KOE) region but relatively low correlation in the Yellow Sea (YS) and East China Sea (ECS). Although some deficiencies were found in the biological components, such as the over/underestimation of the intensity of phytoplankton blooms in the ES and KOE/the YS and ECS, our system demonstrates the capability of the model to capture and record dominant seasonal variability in physical-biological processes and this holds out the promise of coming to a better understanding of such processes and making better predictions .

An Experimental Study on the Effect of Malfunctioning of Drainage System on NATM Tunnel Linings (NATM 터널의 배수시스템 수리기능저하가 터널 라이닝에 미치는 영향)

  • Shin, Jong-Ho;Kwon, Oh-Yeob;Shin, Yong-Suk;Yang, Yu-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • 제23권6호
    • /
    • pp.77-84
    • /
    • 2007
  • One of the most sensitive design specifications to be considered is infiltration and external pore-water pressures on underground structure construction. Development of pore-water pressure may accelerate leakage and consequently cause deterioration of the lining. In this paper, the development of pore-water pressure due to malfunctioning of drainage system and its potential effect on the linings are investigated using physical model tests. The deterioration procedure was simulated by controlling both permeability and flow rate. Development of pore-water pressure was monitored on the lining using pore pressure measurement cells. Test results identified the mechanism of pore-water pressure development on the tunnel lining. In addition, they showed that controlling flow rate is more effective method fur simulating deterioration procedure than permeability control. The laboratory model tests were reproduced using coupled numerical method, and showed that the effect of deterioration of drainage system can be theoretically expected using coupled numerical modeling method.

Modal Parameter Estimation of Membrane for Standard Microphone Sensitivity Calibration (표준 마이크로폰 감도 교정을 위한 진동막의 모달 파라미터 측정)

  • 권휴상;서상준;서재갑;박준홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2002
  • Equivalent volume estimation of the coupler and two coupled microphones has a key role in standard microphone pressure calibration. The equivalent volume of the microphone is determined by the dynamic characteristics of the diaphragm system and front cavity. Therefore the modal parameters of diaphragm system - natural frequency and damping fatter - should be measured explicitly for the estimation of the equivalent volume. The diaphragm system is composed of the vibrating diaphragm, back slit behind diaphragm, pressure equalization vent, and front cavity which are acoustically coupled. In the measurement, the electrostatic actuator was used to excite the system with the swept sine, and the frequency response was obtained. The close actuator in front of the diaphragm must influence the radiation impedance of the system, and then the modal parameters. From the measured frequency response, the natural frequency and the damping factor could be estimated with the Complex exponential method based on the Prony model and the zero crossing real and imaginary plot.

  • PDF

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제18권2호
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

Implementation and Performance Evaluation of a Tightly-Coupled Multiprocessor System (밀결합 멀티프로세서 시스템의 구현 및 성능평가)

  • 김덕진;김영천;박석천
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • 제24권5호
    • /
    • pp.777-785
    • /
    • 1987
  • In this paper, a tightly-coupled multiprocessor system is implemented with four processing elements based on MC68000 CPU, a common menory (128KB), and a single time-shared bus. The multi-tasking operating system, MTOS, is modified so that the multiprocessor system can support multitasking and multiprocessing. The performance of the proposed system is evaluated by stochastic Petri Net system modeling. The efficiency and the processing power are simulated for various load factors and up to 16 PEs. By running benchmark programs, such as quicksort, FFT, and matrix-multiplication, the speed of parallel processing is compared with that of a single processor.

  • PDF

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • International Journal of High-Rise Buildings
    • /
    • 제10권3호
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.

An Area-Efficient DC-DC Converter with Poly-Si TFT for System-On-Glass (System-On-Glass를 위한 Poly-Si TFT 소 면적 DC-DC 변환회로)

  • Lee Kyun-Lyeol;Kim Dae-June;Yoo Changsik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제42권2호
    • /
    • pp.1-8
    • /
    • 2005
  • An area-efficient DC-DC voltage up-converter in a poly-Si TFT technology for system-on-glass is described which provides low-ripple output. The voltage up-converter is composed of charge-pumping circuit, comparator with threshold voltage mismatch compensation, oscillator, buffer, and delay circuit for multi-phase clock generation. The low ripple output is obtained by multi-phase clocking without increasing neither clock frequency nor filtering capacitor The measurement results have shown that the ripple on the output voltage with 4-phase clocking is 123mV, while Dickson and conventional cross-coupled charge pump has 590mV and 215mV voltage ripple, respectively, for $Rout=100k\Omega$, Cout-100pF, and fclk=1MHz. The filtering capacitor required for 50mV ripple voltage is 1029pF and 575pF for Dickson and conventional cross-coupled structure, for Iout=100uA, and fclk=1MHz, while the proposed multi-phase clocking DC-DC converter with 4-phase and 6-phase clocking requires only 290pF and 157pF, respectively. The efficiency of conventional and the multi-phase clocking DC-DC converter with 4-phase clocking is $65.7\%\;and\;65.3\%$, respectively, while Dickson charge pump has $59\%$ efficiency.

Synthesis and characterization of noble metal coupled N-TiO2 nanoparticles

  • Lee, Kyusang;Moon, Jiyeon;Kim, Seonmin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.374.2-374.2
    • /
    • 2016
  • Volatile organic compounds (VOCs) in the atmosphere are harmful materials which influence indoor air environment and human health. Titanium dioxide ($TiO_2$) is photocatalyst extensively used in degradation of organic compound. To improve the photocatalytic activity in the visible light region, doping with non-metals element or loading noble metals on the surface of $TiO_2$ is generally proposed. In this study, N- doped $TiO_2$ having photocatalytic activity in visible light region was attached noble metal such as Pt, Ag, Pd, Au by coupling method. Catalytic activities of Noble metal coupled $N-TiO_2$ powders were evaluated by the improvement of their photocatalytic activities and the degradation of VOC gas. A UV-Vis spectrophotometer was used to measure the diffuse reflectance spectra of coupled $N-TiO_2$ sample. The photocatlytic activities of as prepared samples were characterized by the decoloration of aqueous MB solution under Xenon light source (UV and visible light). To measure of decomposition VOCs, ethylbenzene was selected for target VOC material and the concentration was monitored under UVLED irradiation in a closed chamber system. Adjusting the initial concentration of 10~12 ppm, to evaluate the removal characteristics by using the coupled $N-TiO_2$.

  • PDF