• 제목/요약/키워드: coupled numerical model

검색결과 768건 처리시간 0.027초

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012)

  • 한화택;이대영;김사량;김현정;최종민;박준석;김수민
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

굴 양식수역의 환경용량 산정 -I. 생태계 모델을 이용한 거제 · 한산만 굴 먹이 공급량 추정 (Estimating the Carrying Capacity of a Coastal Bay for Oyster Culture -I . Estimating a Food Supply to Oysters Using an Eco-hydrodynamic Model in Geoie-Hansan Bay-)

  • 박종수;김형철;최우정;이원찬;박청길
    • 한국수산과학회지
    • /
    • 제35권4호
    • /
    • pp.395-407
    • /
    • 2002
  • 거제 $\cdot$ 한산만 굴 양식어장의 수용력 산정에 가장 중요한 요소인 월별 먹이량 변동을 생태-유체역학 모델을 이용하여 산정한 결과는 다음과 같다. 비양식시기인 5월의 거제 $\cdot$ 한산만의 chlorophyll $\alpha$ 농도는 $0.29\~4.72$ (평균 $1.73{\mu}g/L$)로 낮은 농도를 나타내었고, 수평분포 특성은 화도 주변 수역에서 $2.0{\mu}$g/L 이상의 높은 농도 분포를 보인 반면, 만의 중앙부에 해당하는 산달도에서 봉암도 및 율포에 이르는 수역에서 1.4$\mu$g/L 이하의 낮은 농도 분포를 보였다. 거제 $\cdot$한산만의 잔차류는 표층의 경우 외양과 접한 남쪽의 협수로에서는 10 cm/sec의 유속으로 남쪽 방향으로 유출하고, 송도와 비산도 부근에서는 5cm/sec 내외의 유속으로 북서 방향으로 흐름이 진행되었으며, 만 중앙부에서는 내측에서 외측으로 유출하는 형태였으나 유속의 크기는 3cm/sec 이하로 작게 나타났다. 중층은 전반적으로 유속의 크기가 감소하였고, 만 중앙부근에서는 표층의 흐름과는 반대로 만 내측으로의 흐름이 뚜렷하였으며, 저층에서는 수로를 중심으로 흐름이 나타났다. 생태계 모델에 의해 비 양식시기로 가정한 5월의 식물플랑크톤 분포를 재현한 결과 실측치와 계산치의 적합성의 정도를 나타내는 $R^{2}$값은 0.70, 상대오차는 $10.3\%$이었고, 재현된 분포 특성은 화도와 거제시 둔덕면 사이의 수로 부근 수역과 하천의 영향을 많이 받는 만 내측 수역에서 높은 농도분포를 나타내었고, 외해 방향으로 갈수록 점차 낮아지는 경향을 보였다. 이것은 만내로 유입하는 유입부하에 직접적으로 영향을 받고 비교적 정체수역인 만 내측에서 기초생산력이 높다는 것을 나타내었다. 생태계 모델을 이용하여 9월부터 다음해 5월까지 월별 먹이 공급량을 추정한 결과 $0.19\~l.27gC/m^{2}/day$ 범위에 평균 $0.62gC/m^{2}/day$로 나타났다 9월에 1.12gC/m^{2}/day$의 높은 값을 나타낸 이후 점차 감소하기 시작하여 2월에 0.19gC/m^{2}/day$의 최소 값을 나타내었으며, 봄철로 접어들면서 점차 증가하는 양상을 보였고, 5월에 $1.27gC/m^{2}/day$의 최대 값을 나타내었다.

터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구 (Study on Thermal Performance of Energy Textile in Tunnel)

  • 이철호;박상우;손병후;최항석
    • 대한토목학회논문집
    • /
    • 제33권5호
    • /
    • pp.1907-1914
    • /
    • 2013
  • 터널 내부의 지열을 활용하여 지열 냉난방 시스템 가동에 필요한 열에너지를 얻을 수 있는 텍스타일 형태의 지중열교환기(에너지 텍스타일)를 충남 서천군 일대의 철도 폐터널 벽면에 시험 시공하였다. 현장에 설치된 에너지 텍스타일의 성능을 평가하기 위해 냉방 운영과 난방 운영에 대한 일일 냉난방 모사 시험을 수행하였다. 일일 냉난방 모사 시험을 진행하는 동안 터널 벽면에 설치된 지중 열교환기로 유입/유출되는 순환수의 온도, 순환 유량, 터널 벽면 내부 지반의 온도, 터널 내부의 온도를 지속적으로 측정하였다. 시험을 통해 현장에 설치된 에너지 텍스타일은 난방가동에서 에너지 텍스타일 유닛당 57.6~143.5 W의 열교환률을 보였고 냉방가동에서는 362.3~558.4 W의 열교환률을 보였다. 또한, 시험결과로부터 터널에 설치된 지중열교환기의 열교환 성능은 터널 내부 기온의 변화에 큰 영향을 받는 것으로 나타났다. 또한, 전산유체 수치해석을 통하여 터널 내부 기온 변화를 고려한 현장 시험을 모사하여 적용된 수치해석 모델을 검증하였다. 검증된 수치해석 모델을 이용하여 콘크리트 라이닝 내부의 유도 배수재 설치 유무에 따른 에너지 텍스타일의 열적 거동에 대한 매개변수 연구를 수행하였다.

반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(II) -구조개선을 중심으로 (A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter(II) -Structural Improvement)

  • 김진욱;정유진;유정근;손병현
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.985-992
    • /
    • 2011
  • 복합 후처리장치의 최적 모델 개발을 위해 반응기 내부 유동 특성 및 유량 분배 수준 등과 관련지어 3차원 전산유체역학(CFD)을 수행하였다. 백필터의 각 격실별로 유량 분배가 크게 차이가 발생해 반건식 반응기(SDR)에 편류현상이 발생할 것으로 예측되어 백필터에 균등한 유량 분배를 위한 구조 개선이 시급한 것으로 나타났다. 이를 위해, 장치에 3가지 수정.보완(플래넘 구조 개선, 풍도 오리피스 설치, 복수의 흡인 덕트 설치)이 이루어졌다. 이 중에서 플래넘 구조 개선, 풍도 오리피스 설치가 가장 합리적일 것으로 판단된다. 본 해석을 이용하여 수정 보완한 배가스복합 후처리장치는, 반건식 반응기와 백필터 처리부가 일체화되어 있어 장치가 콤팩트하고 설치면적이 적으며 운영 및 관리가 매우 편리할 것으로 판단된다.

반건식 반응기와 백필터를 결합한 하이브리드 대기오염제어 시스템의 수치해석적 연구(I) (A Study on Numerical Calculations of Hybrid Air Pollution Control System Coupled with SDR and Bag Filter)

  • 권영현;김진욱;정유진;김민철;이재정;이강우;손병현
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4656-4663
    • /
    • 2010
  • 본 연구에서는 복합 후처리장치의 최적 모델 개발을 위해 반응기 내부 유동 특성 및 유량 분배 수준, 공기 연령, 체류시간 등과 관련지어 3차원 전산유체역학(CFD)을 수행하였다. 백필터의 각 격실별로 유량 분배가 크게 차이가 발생해 반건식 반응기(SDR)에 편류현상이 발생할 것으로 예측되어 백필터에 균등한 유량 분배를 위한 구조 개선이 시급한 것으로 나타났다. 또한 SDR의 유입구 구조 변경을 통해 반응기 내부의 속도장과 체류시간 분포 특성을 개선할 수 있는 것으로 나타났다. 본 해석을 이용하여 수정 보완한 배가스 복합 후처리장치는, 반건식 반응기와 백필터 처리부가 일체화되어 있어 장치가 콤팩트하고 설치면적이 적으며 운영 및 관리가 매우 편리할 것으로 판단된다.

RANS simulation of secondary flows in a low pressure turbine cascade: Influence of inlet boundary layer profile

  • Michele, Errante;Andrea, Ferrero;Francesco, Larocca
    • Advances in aircraft and spacecraft science
    • /
    • 제9권5호
    • /
    • pp.415-431
    • /
    • 2022
  • Secondary flows have a huge impact on losses generation in modern low pressure gas turbines (LPTs). At design point, the interaction of the blade profile with the end-wall boundary layer is responsible for up to 40% of total losses. Therefore, predicting accurately the end-wall flow field in a LPT is extremely important in the industrial design phase. Since the inlet boundary layer profile is one of the factors which most affects the evolution of secondary flows, the first main objective of the present work is to investigate the impact of two different inlet conditions on the end-wall flow field of the T106A, a well known LPT cascade. The first condition, labeled in the paper as C1, is represented by uniform conditions at the inlet plane and the second, C2, by a flow characterized by a defined inlet boundary layer profile. The code used for the simulations is based on the Discontinuous Galerkin (DG) formulation and solves the Reynolds-averaged Navier-Stokes (RANS) equations coupled with the Spalart Allmaras turbulence model. Secondly, this work aims at estimating the influence of viscosity and turbulence on the T106A end-wall flow field. In order to do so, RANS results are compared with those obtained from an inviscid simulation with a prescribed inlet total pressure profile, which mimics a boundary layer. A comparison between C1 and C2 results highlights an influence of secondary flows on the flow field up to a significant distance from the end-wall. In particular, the C2 end-wall flow field appears to be characterized by greater over turning and under turning angles and higher total pressure losses. Furthermore, the C2 simulated flow field shows good agreement with experimental and numerical data available in literature. The C2 and inviscid Euler computed flow fields, although globally comparable, present evident differences. The cascade passage simulated with inviscid flow is mainly dominated by a single large and homogeneous vortex structure, less stretched in the spanwise direction and closer to the end-wall than vortical structures computed by compressible flow simulation. It is reasonable, then, asserting that for the chosen test case a great part of the secondary flows details is strongly dependent on viscous phenomena and turbulence.

완충재-근계암반 상호작용을 고려한 압축 벤토나이트 완충재 침식 및 파이핑 연구 현황 및 주요 영향인자 도출 (Review of Erosion and Piping in Compacted Bentonite Buffers Considering Buffer-Rock Interactions and Deduction of Influencing Factors)

  • 홍창호;김지원;김진섭;이창수
    • 터널과지하공간
    • /
    • 제32권1호
    • /
    • pp.30-58
    • /
    • 2022
  • 고준위방사성폐기물 심지층처분장은 공학적방벽과 천연방벽의 다중방벽으로 이루어져 있으며 각 방벽재 사이의 상호작용에 의해 처분시스템의 전반적인 장기 건전성이 영향을 받게 된다. 특히 공학적방벽재인 압축 벤토나이트 완충재와 천연방벽인 근계암반의 상호작용에 의한 완충재의 침식 및 파이핑 현상은 사용후핵연료의 붕괴열 발산, 지하수 유입 저지 및 핵종 이동 저지의 역할을 수행하는 완충재의 성능을 저하시키기 된다. 처분 초기에 벤토나이트 완충재가 흡수할 수 있는 물의 양보다 많은 유량이 근계암반의 절리로부터 유입되면 잉여 지하수로 인한 수압이 발생하고 이로 인해 완충재 자체 및 갭채움재 주변으로 파이핑 현상이 발생할 수 있다. 또한 지하수와 벤토나이트 완충재의 물리-화학적 상호작용으로 인하여 완충재의 표면의 팽윤 및 겔/졸화로 인하여 완충재의 표면에서 침식이 발생할 수 있다. 따라서, 이러한 침식 및 파이핑 현상이 발생하는 조건과 이로 인한 완충재의 건전성을 명확하게 평가하는 것이 처분장의 장기건전성 평가를 위해 반드시 필요하다. 처분선진국들에서는 주로 실내 및 공학규모 실험이 수행되고 있으며 일부 전산 모델 개발이 진행되고 있는 상황이지만 실험에서 관측된 현상들을 복합적으로 모사할 수 있는 전산 모델은 개발되지 않았다. 국내에서도 다양한 침식/파이핑 시나리오에 대한 연구나 열-수리-역학-화학적 복합거동을 고려한 연구는 수행되지 않았다. 본 기술 보고에서는 현재까지 수행된 국내외 벤토나이트 침식 및 파이핑 연구와 이들이 주로 고려한 영향인자를 파악하였다. 실험값을 검증하기 위해 제안된 전산 모델들을 소개하고 향후 완충재 침식 및 파이핑 현상 규명을 위한 연구 수행 방향에 대해 정리하였다. 본 논문에서 검토한 다양한 시험 및 모델링 사례를 바탕으로 향후 국내 심층처분장환경을 고려한 압축 벤토나이트 완충재 침식 및 파이핑 관련 연구가 필요하다고 판단된다.