• 제목/요약/키워드: coupled core wall

검색결과 11건 처리시간 0.019초

Seismic performance evaluation of coupled core walls with concrete and steel coupling beams

  • Fortney, Patrick J.;Shahrooz, Bahram M.;Rassati, Gian A.
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.279-301
    • /
    • 2007
  • When coupling beams are proportioned appropriately in coupled core wall (CCW) systems, the input energy from ground motions is dissipated primarily through inelastic deformations in plastic hinge regions at the ends of the coupling beams. It is desirable that the plastic hinges form at the beam ends while the base wall piers remain elastic. The strength and stiffness of the coupling beams are, therefore, crucial if the desired global behavior of the CCW system is to be achieved. This paper presents the results of nonlinear response history analysis of two 20-story CCW buildings. Both buildings have the same geometric dimensions, and the components of the buildings are designed based on the equivalent lateral force procedure. However, one building is fitted with steel coupling beams while the other is fitted with diagonally reinforced concrete coupling beams. The force-deflection relationships of both beams are based on experimental data, while the moment-curvature and axial load-moment relationships of the wall piers are analytically generated from cross-sectional fiber analyses. Using the aforementioned beam and wall properties, nonlinear response history analyses are performed. Superiority of the steel coupling beams is demonstrated through detailed evaluations of local and global responses computed for a number of recorded and artificially generated ground motions.

Free vibration of core wall structure coupled with connecting beams

  • Wang, Quanfeng
    • Structural Engineering and Mechanics
    • /
    • 제10권3호
    • /
    • pp.263-275
    • /
    • 2000
  • In this paper, a core wall structure coupled with connecting beams is discretized and modeled as an equivalent thin-walled member with closed section, while the connecting beams between openings are replaced by an equivalent shear diaphragm. Then, a numerical method (finite member element method, FMEM) for dynamic analysis of the core wall structure is proposed. The numerical method combines the advantages of the FMEM and Vlasov's thin-walled beam theory and the effects of torsion, warping and, especially, the shearing strains in the middle surface of the walls are considered. The results presented in this paper are very promising compared with the ones obtained from finite element method.

The Steel Coupling Beam-Wall Connections Strength

  • 박완신;윤현도
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

병렬전단벽의 강도와 강성이 커플링보의 설계내력에 미치는 영향 (Design Strength of Coupled Shear Wall System according to Variation of Strength and Stiffness of Coupled Shear Wall)

  • 윤태호;김진상
    • 한국산학기술학회논문지
    • /
    • 제17권10호
    • /
    • pp.743-750
    • /
    • 2016
  • 본 연구에서는 초고층건물의 횡력저항 구조형식으로 널리 사용되는 병렬전단벽-커플링보 구조시스템에서 전단벽의 강도, 강성이 커플링보의 설계 강도에 미치는 영향을 분석하였다. 커플링보에 발생하는 설계내력은 코어벽체의 두께와 콘크리트의 강도가 변하더라도 층별 설계내력은 유사한 경향을 보이고 있으며, 벽체 콘크리트 강도와 두께에 따라 커플링보에 발생하는 외력은 다소 감소하는 경향이 있다. 커플링보의 설계내력은 6개 모델 전부 40층 건물에서, 10층에서 15층의 범위에서 가장 높게 발생하고 있음을 알 수 있다. 즉, 병렬전단벽의 휨변형 변곡점이 형성되는 건물높이의 0.25H~0.375H 위치에서 최대 부재력이 발생한다. 벽체두께가 증가 할수록 코어내부의 커플링보의 발생 외력은 점차 증가하는 것으로 확인되었다. 또한 벽체 두께가 두꺼워질수록 벽체의 콘크리트 강도 증가에 따른 커플링보의 부재력 변화는 적게 나타나는데, 이는 벽체 두께가 두꺼우므로 콘크리트 강도변화의 영향이 적게 미치는 것으로 분석된다. 병렬전단벽의 두께증가는 콘크리트의 강도증가보다 강성변화에 큰 영향을 미치고, 이에 따라 커플링보의 부재력 변화에도 더 큰 영향을 미치는 것으로 분석된다.

Multi-scale simulation of wall film condensation in the presence of non-condensable gases using heat structure-coupled CFD and system analysis codes

  • Lee, Chang Won;Yoo, Jin-Seong;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2488-2498
    • /
    • 2021
  • The wall film-wise condensation plays an important role in the heat transfer processes of heat exchangers, refrigerators, and air conditioner. In the field of nuclear engineering, steam condensation is often utilized in safety systems to remove the core decay heat under both transient and accident conditions. In particular, passive containment cooling system (PCCS), are designed to ensure containment safety under severe accident conditions. A computational fluid dynamics (CFD) scale analysis has been conducted to calculate the heat transfer rate of the PCCS. However, despite the increase in computing power, there are challenges in the long-term transient simulation of containment using CFD scale codes. In this study, a heat structure coupling between the CFD and system analysis codes was performed to efficiently analyze PCCS. In addition, the component unstructured program for interfacial dynamics (CUPID) was improved to analyze the condensation behavior of ternary gas mixtures. Thereafter, the condensation heat transfer on the primary side was calculated using the improved CUPID and CFD code, whereas that on the secondary side was simulated using MARS. Both the coupled codes were validated against the CONAN facility database. Finally, conjugate heat transfer simulations with wall condensation in the presence of non-condensable gases were appropriately performed.

주기하중을 받는 이중강판합성벽의 실험연구 (Experimental Study on Double Skin Composite Walls Subjected to Cyclic Loading)

  • 엄태성;박홍근;김진호;장인화
    • 한국강구조학회 논문집
    • /
    • 제20권2호
    • /
    • pp.289-301
    • /
    • 2008
  • 이중강판합성벽은 타이바로 연결된 강판외피 사이에 콘크리트를 충전시킨 구조벽으로서, 벽체의 구조성능을 향상시키고, 벽체의 두께를 줄이며, 별도의 거푸집 및 배근 공사없이 시공성을 향상시키기 위하여 개발되었다. 본 연구에서는 주기하중을 받는 이중강판합성벽의 비탄성거동특성 및 내진성능을 평가하기 위하여, 직사각형 및 T형 단면형상을 갖는 단일벽 및 병렬벽 실험체에 대하여 실험 연구를 수행하였다. 실험 결과, 이중강판합성벽은 주기하중에 대하여 핀칭이 없이 우수한 에너지소산능력을 나타냈다. 벽체하단부 기초의 접합상세와 단면형상에 따라 파괴모드 및 변형능력의 차이를 보였으며, 주로 벽체기초 또는 연결보 용접부의 파단과 강판국부좌굴에 의하여 파괴되었다. 적절한 용접 및 보강 상세를 갖는 실험체들은 2.0~3.7% 층간변형각의 변형능력을 보였다. 또한 벽체와 연결보의 비탄성강도를 고려하여 단일벽 및 병렬벽 실험체의 하중재하능력을 평가하였으며, 이를 실험결과와 비교하였다.

커플링 보의 접합방식에 따른 복합 벽체 시스템에 관한 연구 (A Study on Hybrid Wall System on Connection Type of Coupling Beam)

  • 윤현도;박완신;한병찬;윤여진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.201-208
    • /
    • 2003
  • 철근콘크리트 코어 벽체와 외부 철골골조로 구성된 복합벽체시스템은 중앙 코아 전단벽 주변의 오픈공간을 갖는다. 이와 같은 복합 벽체시스템은 연결된 벽체가 대부분의 횡하중에 저항하고 벽체저면과 커플링 보에서 대부분의 에너지를 소산할 수 있는 설계기법을 개발하는 것이 필요하다. 본 연구논문은 커플링 보의 접합방식 및 층규모를 주변수로 수직하중 및 풍하중과 지진하중을 받는 복합 벽체시스템에 대하여 전단력, 전도모멘트, 최대 횡변위, 층간변위비 및 동적특성을 규명하였다.

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

노심용융사고 시 관통노즐이 제거된 원자로용기 하부헤드의 구조 건전성 평가 (Structural Integrity Evaluation of Reactor Pressure Vessel Bottom Head without Penetration Nozzles in Core Melting Accident)

  • 이연주;김종민;김현민;이대희;정장규
    • 한국전산구조공학회논문집
    • /
    • 제27권3호
    • /
    • pp.191-198
    • /
    • 2014
  • 본 논문에서는 노심용융사고 시 관통노즐이 제거된 원자로용기 하부헤드의 구조 건전성 평가를 수행하였다. 열응력, 노심용융물의 질량 그리고 내압조건의 해석결과를 고려할 때, 하부헤드의 열응력에 의한 영향이 가장 크게 나타났다. 손상 가능성은 파손기준에 따라 평가하였으며, 등가소성변형률이 임계변형률 파손기준보다 낮은 수준으로 평가되었다. 열-구조물 연성해석 결과 하부헤드의 두께 중간층에서 항복강도보다 낮은 응력이 발생한 탄성영역 구간을 확인하였다. 내압이 커지면서 탄성영역 범위가 점차 좁아지면서 탄성영역이 내벽으로 이동하는 결과를 확인하였고, 노심용융사고 시 구조적 건전성을 만족하는 것으로 평가되었다.

안테나에서 페라이트 위치 변화에 따른 전자계 시뮬레이션과 전기적.광학적 특성 (Electromagnetic Simulation & Electrical.Optical Characteristics by Changing Ferrite Position in Antenna)

  • 이주호;양종경;이종찬;최명현;김병택;박대희
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.816-820
    • /
    • 2008
  • The RF inductive discharge of inductively couples plasma (ICP) continues to attract growing attention as an effective plasma source in many industrial applications, the best known of which are plasma processing and lighting technology. Although most practical ICPs operate at 13.56 [MHz] and 2.65 [MHz], the trend to reduce the operating frequency is clearly recognizable from recent ICP developments. In an electrodeless fluorescent lamp, the use of a lower operating frequency simplifies and reduces cost of RF matching systems and RF generators and can eliminate capacitive coupling between the inductor coil and plasma, which could be a strong factor in wall erosion and plasma contamination. In this study, We discussed simulation and experimental results when changing ferrite position in antenna.