Partial Discharge Characteristics due to shift of Void Position in XLPE (XLPE에서 보이드 위치변화에 따른 부분방전특성)

  • Kim, Tag-Yong;Yang, Jae-Hoon;Kim, Weon-Jong;Shin, Hyun-Taek;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.86-89
    • /
    • 2004
  • To estimate a electrical performance of the extra high voltage XLPE cable the discharge properties due to shift of void position were investigated. The ${\phi}-q-n$ properties have been measured at room temperature by rising voltage ratio of 0.5[kV]. An obtained data was stored to personal computer through A/D converter. The period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that the charge, phase angle and counts of discharge changed due to void position.

  • PDF

Life Time Diagnosis and Partial Discharge Characteristics due to shift of Void Position in XLPE (XLPE 내부 보이드 위치변화에 따른 부분방전 특성 및 수명예측)

  • Kim, Tag-Yong;Cho, Kyung-Soon;Shin, Hyun-Taek;Kim, Kwi-Yeol;Lee, Kang-Sung;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.256-257
    • /
    • 2005
  • To estimate a electrical performance of the extra high voltage XLPE cable the discharge properties due to shift of void position were investigated. The $\Phi-q-n$ properties have been measured at room temperature by rising voltage ratio of 0.5[kV]. An obtained data was stored to personal computer through A/D converter. The period of applied wave form and discharge values were divided into 64 parts and discharge values generated during 10 seconds were accumulated by phases. As a result, it was confirmed that the charge, phase angle and counts of discharge changed due to void position.

  • PDF

Bacterial Removal Efficiencies by Unit Processes in a Sewage Treatment Plant using Activated Sludge Process (활성슬러지공정 하수종말처리장의 단위공정별 세균 제거효율)

  • Lee, Dong-Geun;Jung, Mira;Sung, Gi Moon;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.871-879
    • /
    • 2010
  • To figure out the removal efficiency of indicator and pathogenic bacteria by unit processes of a sewage treatment plant using activated sludge process, analyses were done for incoming sewage, influent and effluent of primary clarifier, aeration tank, secondary clarifier and final discharge conduit of the plant. A matrix of bacterial items (average of bacterial reduction [log/ml], p value of paired t-test, number of decreased cases of twenty analyses, removal percentage only for decreased cases) between incoming sewage and final effluent of the plant were heterotrophic plate counts (1.54, 0.000, 20, 95.01), total coliforms (1.38, 0.000, 19, 83.94), fecal coliforms (0.90, 0.000, 20, 94.84), fecal streptococci (0.90, 0.000, 20, 98.08), presumptive Salmonella (0.23, 0.561, 7, 99.09), and presumptive Shigella (1.02, 0.002, 15, 92.98). Total coliforms, fecal coliforms, heterotrophic plate counts, and fecal streptococci showed highest decrease through secondary clarifier about 1-log (p<0.001) between 88% and 96%, and primary clarifier represented the significant (p<0.05) decrease. However, final effluent through discharge conduit showed higher total coliforms and fecal streptococci than effluent of secondary clarifier (p<0.05). In addition, final effluent once violated the water quality standard while effluent of secondary clarifier satisfied the standard. Hence some control measures including elimination of deposits in discharge conduit or disinfection of final effluent are necessary.

Detection and Location of Partial Discharge in Transformers (변압기내 부분방전 탐지 및 위치검출)

  • 곽희노;김재철;황선주;권태원;윤용범
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.4
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor (로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출)

  • Kwak, Hee-Ro;Kim, Jae-chul;Kim, Eung-Sang;Han, Min-Koo;Kwan, Tae-Won;Yoon, Young-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Seasonal Variation in the Phytoplankton and Bacterial Fauna in the Mid to Lower Reaches of the Nakdong River (낙동강 중.하류에서 식물플랑크톤과 세균의 계절적 동태)

  • Park, Jae-Rim;Ha, Kyong;Son, Yeon-Ju;Ju, Gea-Jae
    • Journal of Environmental Science International
    • /
    • v.10 no.4
    • /
    • pp.259-267
    • /
    • 2001
  • Investigations were carried out to observe the seasonal succession of phytoplankton, and viable counts of bacteria from the mid to lower reaches of Nakdong Fiver. An intensive monitoring was conducted from May to December 1999 biweekly at 6 sites in a main channel and 3 tributaries. Although there are several sites with high nutrient loading from the basin, all of study sites showed mesotrophic states owing to high discharge(June~September). Relatively low algal biomass and CFUs(mean of chi. a, $12.3{\pm}$11.5 $\mu\textrm{g}${\el}l$, CFUs : 1.8${\times}10^7$) were observed during the rainy season. The diatom population was dominant(over 85% of total community) year-long with peaks(Stephanodiscus hantzchii) in the fall and winter. Dominance of blue-green algal groups during the summer was not observed in the summer. Microorganisms peaked in the summer and fall(June~September), affected mainly by the inputs of phytoplankton and nutrients. Biomass of phytoplankton and CFU counts were higher in the Kumho River than other tributaries and main channel.

  • PDF

Technique of Transformer Diagnosis Using Ultrasonic Sensor (초음파 센서를 이용한 변압기 예방진단 기술 연구)

  • 권동진;최수안;박형준;곽희로;정찬수;전희종;김재철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.2
    • /
    • pp.46-53
    • /
    • 1994
  • This paper presents a diagnosis teclmique using ultrasonic sensors for monitoring the growth of partial discharge in power transformers. This teclmique counts the ultrasonic pulses generated from partial discharge over a threshold leveL In experiments, a ultrasonic generator and the point to plane electrodes generated ultrasonic pulses. With a constant voltage between the electrodes, the ultrasonic pulses over a threshold were a fairly constant. When the voltage increased or insulation paper was inserted between the electrodes, the partial discharge increased. In this case the number of ultrasonic pulses also increased and therefore the proposed teclmiques successfully diagnosed the growth of partial discharge.

  • PDF

A Study on the EDT Characteristics of TM Work Roll and Variation of Strip Surface Roughness

  • Kim, Soon-Kyung;Moon-Kyung, Kim
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.133-137
    • /
    • 2001
  • This paper investigates the correlation between strip surface roughness and the surface of the work roll. As the actual temper mill(TM) is used, this data will be adopted to another actual temper mill for the application and operation of this experiment. Conclusions are as follows: Electro-discharge texturing(EDT) roll has homogeneous roughness distribution and shape, and also a sinuous peak surface and the life is 2 times longer than that of shot blast texturing(SBT) method. And the higher surface roughness of work roll, the more time is necessary at the EDT method. In the SBT method without the correlation of roughness, but impeller rotation speed with an uncontrollable peak count. The roughness of SBT roll is irregularity compared to that of EDT roll because the work roll roughness is transferred to the strip which was temper rolled, and produces a more desirable image and greater clarity to the color painted steel sheet.

  • PDF

Tree Shape and Partial Dishcharge in LDPE Blended with Organic Compounds (유기화합물이 첨가된 LDPE에서의 트리 형상과 부분방전)

  • Kang, S.H.;Choi, H.S.;Shin, Y.S.;Jeong, D.Y.;Lim, K.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1130-1133
    • /
    • 1993
  • In this paper, it is discussed the correlation between shape of tree and internal partial discharge in low density polyethylene(LDPE) blended with organic compounds that used to improve the effect of resistance to treeing. Initiation and growing of tree are retarded in specimens blended with organic compounds that comprised radical having large electron affinity, and also discharge magnitude and counts of discharging pulse per unit time in these samples are more than those in others. It is observed that the shape of tree in these samples is bush type, but in case of pure LDPE samples dendrite type.

  • PDF