• Title/Summary/Keyword: cost control

Search Result 5,839, Processing Time 0.052 seconds

Comparison of Heating Characteristics of Electric Heating Element Heater and Oil Hot Air Heater in Single Span Greenhouses (전기발열체 난방기 및 유류온풍 난방기의 단동온실 난방 특성 비교)

  • Kwon, Jin Kyung;Kim, Seung Hee;Shin, Young An;Lee, Jae Han;Park, Kyeong Sub;Kang, Youn Koo
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.324-332
    • /
    • 2017
  • The comparative experiments were conducted for single span greenhouses where cucumbers were cultivated to analyze the effect of heating between a carbon fiber electric heating element heater and an oil hot air heater in terms of the inside climate, energy consumption and plant growth. In order to analyze the effect of heating capacity, 6, 9, and 16 kW of electric powers were supplied to the electric heating element for same setting temperature of 15?. As a result, as the heating capacity increased, the number of ON-OFF cycles of the electric heating element and the temperature inside the greenhouse increased proportionally. In the comparison of two heaters, it was shown that the temperature and relative humidity distributions of the electric heating element installed greenhouse was much uniform than those of the oil hot air heater installed greenhouse. The heating energy consumptions during the heating period of 79 days were 867L for the oil hot air heater and 8,959 kWh for the electric heating element heater, and the heating costs were 607 and 403 thousand won respectively. In the electric heating element installed greenhouse, the cucumber growth was slightly better and the yield was 4.3% higher than those of the oil hot air heater installed greenhouse, but there were no statically significant difference in the cucumber growth and yield between greenhouses.

Variation Analysis of Distance and Exposure Dose in Radiation Control Area and Monitoring Area according to the Thickness of Radiation Protection Tool Using the Calculation Model: Non-Destructive Test Field (계산 모델을 활용한 방사선방어용 도구 두께에 따른 방사선관리구역 및 감시구역의 거리 및 피폭선량 변화 분석 : 방사선투과검사 분야 중심으로)

  • Gwon, Da Yeong;Park, Chan-hee;Kim, Hye Jin;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.279-287
    • /
    • 2020
  • Recently, interest in radiation protection is increasing because of the occurrence of accidents related to exposure dose. So, the nuclear safety act provides to install the shields to avoid exceeding the dose limit. In particular, when the worker conducts the non-destructive testing (NDT) without the fixed shielding structure, we should monitor the access to the workplace based on a constant dose rate. However, when we apply for permits for NDT work in these work environments, the consideration factors to the estimation of the distance and exposure dose are not legally specified. Therefore, we developed the excel model that automatically calculates the distance, exposure dose, and cost if we input the factors. We applied the assumption data to this model. As a result of the application, the distance change rate was low when the thickness of the lead blanket and collimator is above 25 mm, 21.5 mm, respectively. However, we didn't consider the scattering and build-up factor. And, we assumed the shape of the lead blanket and collimator. Therefore, if we make up for these limitations and use the actual data, we expect that we can build a database on the distance and exposure dose.

The Change of Health Service before and after the Unification of two Health Subcenters in a Rural Area (한 농촌지역 2개면 보건지소 통합전후 보건의료사업 변화 연구)

  • Sul, Sue-Jeong;Park, Hyang;Sohn, Seok-Joon;Park, Jong;Kim, Ki-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.2
    • /
    • pp.427-440
    • /
    • 2000
  • A comparative study was made about health resources, medical care service statistics and public health service statistics by health subcenters at Jangdong and Jangpyung townships, Jangheung County, Chollanamdo before and after the unification of two health subcenter to improve their function. 1. While two general physicians, one dentist, 4 nurse aids arid one oral hygienist were working at two health subcenters with simple facility with examination room and public health office in 1997 prior to the unification, in 1999 after the unification of two health subcenters 14 staff including a specialist physician, a general physician, a dentist, a herb hygienist, a radiology technician and a physical therapist were working in the new health subcenters equipped with appropriate facilities in two storey building. 2. In 1997 before the unification the yearly total income of two health subcenters was 78,815 thousand won(about 14,000 won per capita) and the amount was 140,376 thousand won(about 25,000 won per capita) in 1999 after the unification. And the income was used for operation of health subcenters excluding personnel expense. 3. While 90.5% of visitors to the health subcenters came for general medical care, and 91.6% came for the revisit before the unification, after the unification 71.2% came for general medical care, 10.8% for dental care, 16.5% for oriental physician's care, 29.7% for the first visit and 70.3% for revisit. Most common problem cared for was musculoskeletal disorder like arthralgia. Average treatment cost per person per month was 9,363 won before the unification and 8,309 won after the unification. 4. Through the comparison of execution rate of public health services before and after the unification. the practice rate of most health service among target population including visiting service for chronic illness, maternal and child health service and immunization service increased after the unification. The practice rate of tuberculosis control service, hypertension control and diabetes management was a little decreased. In conclusion, continuous effort to satisfy all persons in two townships and evaluation are necessary to coincide with the spirit of unification of two health subcenters.

  • PDF

암환자 인식에 관한 연구 - 간호사ㆍ의사를 중심으로

  • Jo, In-Hyang
    • Korean Journal of Hospice Care
    • /
    • v.2 no.1
    • /
    • pp.58-74
    • /
    • 2002
  • This paper constitutes a descriptive investigation and used a structured questionnaire to investigate nurses' and doctors' recognition of cancer patients. The subjects were extracted from the medical personnel working at the internal medicine, the surgery ward, the obstetrics and gynecology department, the pediatrics department, the cancer ward, and the emergency room of five general hospitals located in Seoul and Gyeonggi Province. The research lasted from August, 2001 to September 2001. Total 137 nurses and 65 doctors were included and made out the questionnaires directly distributed by the investigator. The study tool was also developed by the investigator and consisted of such items as the demographic and social characteristics, the medical personnel's recognition degree of cancer and cancer patients, their recognition of the management of cancer patients, and their participation in a hospice. The results were analyzed using the SPSS Window program in terms of technological statistics, ranks, t-test, and ANOVA. The reliability was represented in Cronbach' α=.75. The nurses' and doctors' recognition degree of cancer and cancer patients had an overall average of 3.86 at the 5 point-scale. The items that received an average of 4.0 or more included 'Medical personnel should explain about the cancer cure plans to the cancer patient and his or her family', 'A patient whose case has been diagnosed as a terminal cancer should be notified of it, 'If I were a cancer patient, I would want to get informed of it,' and 'Cancer shall be conquered whenever it is'. In the meantime, the items that received an average of 3.0 or less was 'My relationship with the cancer patient's family has gotten worse since I announced his or her impending death.' And according to the general characteristics and the difference test, the recognition degree of cancer and cancer patient was high among the subgroups of nurses, females, married persons, who were in their 30s, who had a family member that was a cancer patient, and who received a hospice education. The biggest number of the nurses and doctors saw 'a gradual approach over several days'(68.8%) as a method to tell a cancer patient about his or her cancer diagnosis or impending death. Those who usually tell tragic news were the physician in charge(62.8%), the family members or relatives(32.1%) and the clergymen(3.8%) in the order. The greatest number of them recommended a cancer patient's home as the place where he or she should face death because they thought 'it would stabilize his or her mentality'(91.9%) while a number of them recommended the hospital because they 'should give the psychological satisfaction to the patient'(40%) or 'should try their best until the last moment of the patient's death'(30%). A majority of the medical personnel regarded 'smoking or drinking' and 'diet' as the causes of cancer. The biggest symptom of a cancer patient was 'pain' and the pain management of a cancer patient was mostly impeded by the 'excessive fear of drug addiction, tolerance to drugs and side effects of drugs' by medical personnel, the patient, and his or her family. The most frequently adopted treatment plan of a terminal cancer patient was 'to do whatever the patient or his or her family wants' to resort to a hospice' and 'to continue active treatment efforts' in the order. The biggest reasons why a terminal cancer patient went to see a doctor were 'pain alleviation' 'control of symptoms other than pain(intravenous supply)' and 'incapability of the patient's family' in the order. Terminal cancer patients placed their major concern in 'spiritual(religious) matter' 'emotional matters' their family' 'existence' and 'physical matters' in the order. 113(58.5%) of the whole medical personnel answered they 'would recommend' an alternative treatment to a terminal cancer patient mostly because they assumed it would 'stabilize the patient's mentality.' Meanwhile, 80(41.5%) of them chose 'not to recommend it mostly due to the unverified effects and high cost of it(78.7%). A majority of them, I. e. 190(94.1%) subjects said they 'would recommend' a hospice to a terminal cancer patient mostly because they thought it would help the patient to 'mentally prepare'(66.6%) Only 17.3% of them, however, had received a hospice education, most of which was done through the hospital duty education(41.4%) and volunteer training(34.5%). The follows are results of this study: 1. The nurses and the doctors turned out to be still passive and experience confusion in dealing with a cancer patient despite their great sense of responsibility for him or her. 2.Nurses and Doctors realize the need of a hospice, but an extremely small number of them participate in a hospice education or performance. Thus, a whole recognition of a hospice should be changed, for which purpose a hospice education for nurses and doctors should be provided. 3.Terminal cancer patients preferred their home to a hospital as the place to face their impending death because they felt it would bring 'mental stability.' And most of nurses and doctors think it would be unnecessary for them to be hospitalized just for control of their symptoms. Accordingly a terminal cancer patient can be cared at home, and a home hospice care needs to be activated.

  • PDF

Analysis on the Characteristics of Ventilation and Cooling for Greenhouses Constructed in Reclaimed Lands (간척지 온실의 환기 및 냉방 특성 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. The climatic conditions around seven major reclaimed land areas with a plan to install advanced horticultural complexes in Korea were analyzed. The characteristics of natural ventilation and temperature rise through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. Results of comparing the ventilation rate of the greenhouse according to the presence or absence of plants showed the greenhouse with plants had the lower ventilation rate, but the smaller rise of indoor temperature due to the evapotranspiration of plants. In the greenhouse with plants, the number of air changes was in the range of 0.3 to 0.9 volumes/min and the average was 0.7 volumes/min. The rise of indoor temperature relative to outdoor temperature was in the range of 1 to $5^{\circ}C$ and the average $2.5^{\circ}C$. The natural ventilation performance of the experimental greenhouse constructed in the reclaimed land almost satisfied the recommended ventilation rate in summer and the rise of indoor temperature relative to outdoor temperature did not deviate considerably from the cultivation environment of plants. Therefore, it was determined that the greenhouse cultivation in Saemangeum reclaimed land is possible with only natural ventilation systems without cooling facilities. As the reclaimed land is located in the seaside, the wind is stronger than the inland area, and the fog is frequent. This strong wind speed increases the ventilation rate of greenhouses, which is considered to be a factor for reducing the cooling load. In addition, since the fog duration is remarkably longer than that of inland area, the seasonal cooling load is expected to decrease, which is considered to be advantageous in terms of the operation cost of cooling facilities.

Study of the UAV for Application Plans and Landscape Analysis (UAV를 이용한 경관분석 및 활용방안에 관한 기초연구)

  • Kim, Seung-Min
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • This is the study to conduct the topographical analysis using the orthophotographic data from the waypoint flight using the UAV and constructed the system required for the automatic waypoint flight using the multicopter.. The results of the waypoint photographing are as follows. First, result of the waypoint flight over the area of 9.3ha, take time photogrammetry took 40 minutes in total. The multicopter have maintained the certain flight altitude and a constant speed that the accurate photographing was conducted over the waypoint determined by the ground station. Then, the effect of the photogrammetry was checked. Second, attached a digital camera to the multicopter which is lightweight and low in cost compared to the general photogrammetric unmanned airplane and then used it to check its mobility and economy. In addition, the matching of the photo data, and production of DEM and DXF files made it possible to analyze the topography. Third, produced the high resolution orthophoto(2cm) for the inside of the river and found out that the analysis is possible for the changes in vegetation and topography around the river. Fourth, It would be used for the more in-depth research on landscape analysis such as terrain analysis and visibility analysis. This method may be widely used to analyze the various terrains in cities and rivers. It can also be used for the landscape control such as cultural remains and tourist sites as well as the control of the cultural and historical resources such as the visibility analysis for the construction of DSM.

Studies on the Herbicidal Properties of Pyrazolate (제초제(除草劑) Pyrazolate의 작용특성(作用特性)에 관한 연구(硏究))

  • Ryang, H.S.;Han, S.S.;Kim, K.H.
    • Korean Journal of Weed Science
    • /
    • v.3 no.2
    • /
    • pp.174-189
    • /
    • 1983
  • Experiments were conducted to evaluate the herbicidal characteristics of pyrazolate [4-(2,4-dichloro benzoyl)-1,3-dimethylpyrazol-5-yl-p-toluene-sulphonate] in greenhouse and lowland rice field. Pyrazolate controlled effectively most of annual weeds and such perennial weeds as Sagittaria pygmaea MIQ., Potamogeton distinctus A. BENN, Sagittaria trifolia L., Cyperus serotinus ROTTB, and Scirpus hotarui OHWI., whereas Eleocharis kuroguwai OHWI. was tolerent to pyrazolate. Although pyrazolate was applied at 2 to 10 days after transplanting, there was no difference in weed control The weeding effect was not influenced by percolation, depth of water and soil type. No difference in crop injury of rice was found with various levels of seedling age, transplanting depth, percolation, depth of water, soil type and time of application. When combined with butachlor, the mixture gave the same effect on rice phytotoxicity and weed control as pyrazolate alone did. Pyrazolate moved 1 to 2cm downward in lowland soil regardless of soil type and percolation. The herbicidal activity of pyrazolate persisted in soil for 60 to 90 days, depending on soil type, percolation and presence of soil microorganism.

  • PDF

Development of Dust Recycling System and Dust Cleaner in Pipe during Vitrification of Simulated Non-Radioactive Waste (모의 비방사성폐기물의 유리화시 발생 분진의 재순환처리장치 및 배관 내 침적분진에 의한 막힘 방지용 제진장치의 개발)

  • Choi Jong-Seo;You Young-Hwan;Park Seung-Chul;Choi Seok-Mo;Hwang Tae-Won;Shin Sang-Woon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.110-120
    • /
    • 2005
  • For utilizing vitrification to treat low and intermediate level waste, industrial pilot plant was designed and constructed in October 1999 at Daejon, Korea through the joint research program among NETEC, MOBIS and SGN. More than 70 tests were performed on simulated IER, DAW etc. including key nuclide surrogate(Cs, Co); this plant has been shown to vitrify the target waste effectively and safely, however, some dust are generated from the HTF(High Temperature Filter) as a secondary waste. In case of long term operation, it is also concerned that pipe plugging can be occurred due to deposited dust in cooling pipe namely, connecting pipe between CCM(Cold Crucible Melter) and HTF. In this regard, we have developed the special complementary system of the off-gas treatment system to recycle the dust from HTF to CCM and to remove the interior dust of cooling pipe. Main concept of the dust recycling is to feed the dust to the CCM as a slurry state; this system is regarded as of an important position in the viewpoint of volume reduction, waste disposal cost and glass melt control in CCM. The role of DRS(Dust Recycling System) is to recycle the major glass components and key nuclides; this system is served to lower glass viscosity and increase waste solubility by recycling B, Na, Li components into glass melt and also to re-entrain and incorporate into glass melt like Cs, Co. Therefore dust recycling is helpful to control the molten glass; it is unnecessary to consider a separate dust treatment system like a cementation equipment. The effects of Dust Cleaner are to prevent the pipe plugging due to dust and to treat the deposited dust by raking the dust into CCM. During the pilot vitrification test, overall performance assessment was successfully performed; DRS and Dust Cleaner are found to be useful and effective for recycling the dust from HTF and also removing the dust in cooling pipe. The obtained operational data and operational experiences will be used as a basis of the commercial facility.

  • PDF

Heating Efficiency of Difference Heat Collection Methods for Greenhouse (유리온실의 태양열 집열방법별 집열효과)

  • 최영하;이재한;권준국;박동금;이한철
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.166-170
    • /
    • 2000
  • Three methods for heat collection, which were the flat solar collector, two fan with radiator, and square pipe method, were studied to sue efficiently solar energy in the three different glasshouses for two years. The flat plate solar collector method was made use of the commercial solar collector with collection area of 24$m^2$, the method of two fans with radiators collected solar energy at the top of the glasshouse. An thermal storage tank was constructed underneath in teach glasshouses. When an area of 1,000$m^2$ was heated to the minimum temperature of 9$^{\circ}C$, the decrease rate of heating fuel for the flat plate solar collector, the fan attached radiator and the square pipe methods were 7%, 19% and 28% respectively. The flat plate solar collector method, which could be heated approximately 40-50$m^2$, was currently used by most of the farmer. Under the condition, the decrease rate of annual heating fuel was 14% which was not better for an economic annual heating fuel. If the fan with radiator method was operated, the use of installation and maintenance were required. So, it could not be good economic efficiency of solar heating. The heating efficiency of the square pipe method was relatively better thant those of the flat plate solar collector or the fan attached radiator. Since the cost of materials and its installation of the use of square pipe method was lower than any other method. However, corrosion of the pipe, greater shade in the greenhouse and strength against the square pipe were problems that should be overcome in the square pipe method.

  • PDF

Uplift Capacity of Wood Pile for Greenhouse Foundation (온실 기초용 나무말뚝의 인발저항력 검토)

  • Yun, Sung Wook;Choi, Man Kwon;Lee, Si Young;Yu, Chan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Wood piles are rarely used in the construction of a greenhouse in Korea, but they are relatively more often used in other countries, such as the Netherlands. There are several advantages associated with wood piles: they are more cost-effective, less time-consuming, and more ecofriendly than the steel pipes (SPs) and pre-stressed highstrength (PHC) piles. However, one of the limiting conditions is that they have to be installed below the groundwater level to prevent decay. Since the groundwater levels are generally high in the reclaimed lands in Korea, wood piles are expected to be used often as reinforcements for foundations of greenhouses in these areas. In this study, we measured the uplift capacities of wood piles through in-situ uplift capacity tests with an aim to provide basic design data for wood pile foundations. In order to test their applicability, we then compared these experimentally measured ultimate uplift capacities with the ones calculated through some of the existing theoretical equations. The wood piles used in the loading tests were made of softwood (pine wood), and the tests were performed using piles with different diameters (∅25cm and ∅30cm) and embedded depths (1m, 3m, and 5m). The test results revealed that the uplift capacity of the wood piles showed a clear linearly increasing tendency in proportion to the embedded depth, with the ultimate uplift capacities for the diameters 25cm and 30cm being 9.38 and 10.56tf, respectively, at the embedded depth of 5m; thus demonstrating uplift capacities of ${\geq}9tf$. The comparison between the actually measured values of the uplift capacity and the ones calculated through equations revealed that the latter, which were obtained using the ${\alpha}$ method, were generally in an approximate agreement with the in-situ measured values.