• Title/Summary/Keyword: cortical thickness

Search Result 163, Processing Time 0.023 seconds

Studies of SAMP6 as an Animal Model for Human Osteoporosis (골다공증 모델동물, SAMP6의 특성 연구)

  • 김은주;김양범;송창우;한상섭
    • Journal of Life Science
    • /
    • v.9 no.2
    • /
    • pp.182-193
    • /
    • 1999
  • In order to establish basic data of SAMP6 as an animal model for osteoporosis, present study has been designed to concentrate on the various biological aspects of SAMP6 such as growth index, hematology, blood biochemistry, biochemical characteristics, and bone and cortical thickness. Investigation period was for 15 months (3 months to 18 months of age) and biological characteristics have been examined throughout the study period. The results were summarized as follows : Decreased body weight of male SAMP6 was noticed from 7 months of age compared to from 18 months of age in female. Although there were no significant differences in organ weights, generally those of male mice were greater than those of females, especially in liver, kidney and lung. According to the analysis of blood biochemistry and hematology, the number of leukocytes in male mice was greater than that of female mice. There was a decrease in bone thickness in both male and female mice starting around from 7 months of age. Peak cortical thickness index was noticed at 5 months of age in both sexes. In femur, the highest $Ca^{2+}$ content for both sexes was noticed at 5 months of age, whereas the highest P$^{3+}$ content was noted at the age of 5 and 7 months in male and female mice, respectively. The contents of both elements were gradually decreased with age after peaks for both sexes. In summary, SAMP6 mice in KRICT colony show osteoporotic characteristics starting from 5 to 7 months of age, suggesting that at least 5 months of old animals should be used for studying the mechanism of osteoporosis or screening anti-osteoporosis drugs. This study also suggests that the cortical index thickness, $Ca^{2+}$ and P$^{3+}$ contents, and alkaline phosphatase activities can be used as indexes for drug screening.

  • PDF

Quality and Morphology on cortico-cancellous bone in Korean mandibular symphysis area (한국인 하악 유합부에서의 피질골-해면골의 밀도 및 형태)

  • Min, Cheon-Ki;Park, Hyun-Do;Kim, Chang-sung;Jung, Han-Sung;Cho, Kyoo-Sung;Kim, Hee-Jin;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.3
    • /
    • pp.581-595
    • /
    • 2001
  • In performing implant procedures in the anterior portion of the maxilla, many difficulties exist because of anatomical reasons, such as the proximity of the nasal floor, lateral extension of the incisive canal, and labial concavity. On the other hand, in the posterior region of the maxilla, there is often insufficient recipient bone between the maxillary sinus and alveolar ridge due to alveolar ridge resorption and pneumatization of the maxillary sinus. In order to perform implants in such regions, ridge augmentation procedures such as onlay bone graft, guided bone regeneration, and maxillary sinus grafting are performed. In studies of Caucasians, use of autograft from mandibular symphysis has been reported to be highly successful in maxillary sinus grafting. However, in a clinical study of Koreans, autograft of mandibular symphysis has been reported to have significantly low success rate. It has been hypothesized that this is because of insufficient cancellous bone due to thick cortical bone. In order to test this hypothesis, bone quality and morphology of Koreans can be compared with those of Caucasians. In this study, the bone density and morphology of the cortical bone and cancellous bone in the mandibular symphysis of 35 Korean cadavers were evaluated. The following results were obtained: 1. In terms of bone density, type I, type II, and type III consisted of 1.4%(3/213), 72.3%(154/213), and 26.3%(56/213) of the cross-sectioned specimens, respectively. In general, the bone density tended to change from type II to type III, as cross-sectioned specimens were evaluated from the midline to the canine. Type IV wasn't observed in this study. 2. The distance between the root apex and the lower border of the cancellous bone was 18.34mm-20.59mm. Considering that the bone has to be cut 5mm below the root apex during the procedure, autografts with about 15mm of vertical thickness can be obtained. 3. The thickness of cortical bone on the labial side increased from the root apex to the lower border of the mandible. The average values ranged from 1.43mm to 2.36mm. 4. The labio-lingual thickness of cancellous bone ranged from 3.43mm to 6.51mm. The thickness tended to increase from the apex to the lower border of the mandible and decrease around the lower border of cancellous bone. From the above results, the anatomic factors of the mandibular symphysis (bone density, thickness, quantity and length of the cortical bone and cancellous bone) didn't show any difference from Caucasians, and it cannot be viewed as the cause of failure in autografts in the maxillary sinus for implants.

  • PDF

THE STUDY ABOUT THE DIAGNOSTIC PARAMETERS OF OPSTEOPOROSIS ON PANORAMIC RADIOGRAPH (골다공증의 파노라마방사선사진상 진단학적 매개변수에 관한 연구)

  • Lee, Yong Gyoo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.279-283
    • /
    • 1998
  • The osteoporosis is a disease that represents a reduction in the volume of bony tissue relative to whole bone volume. And mandible also may be affected. Such porotic mandible may influence the result of the surgery like dental implant surgery relating mandible. So, the author examed the panoramic view of 89 persons for finding the possibility of useful diagnostic parameters of osteoporosis. To know the correlationship between the condition of vertebra and mandible, bone marrow density of lumbar spine from 2nd to 4th, and the number of residual tooth, panoramic mandibular index (PMI), angular cortical bone thickness (ACT) and ramus cortical bone thickness (RCT) were compared. The result is that PMI and ACT have similar relative weak linear correlationship, RCT have very weak linear correlationship, the number of residual tooth have not linear correlationship.

  • PDF

Assessment of the relationship between the maxillary molars and adjacent structures using cone beam computed tomography

  • Jung, Yun-Hoa;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.219-224
    • /
    • 2012
  • Purpose: This study investigated the relationship between the roots of the maxillary molars and the maxillary sinus using cone beam computed tomography (CBCT), and measured the distances between the roots of the maxillary molars and the sinus floor as well as the thickness of the bone between the root and the alveolar cortical plate. Materials and Methods: The study sample consisted of 83 patients with normally erupted bilateral maxillary first and second molars. A total of 332 maxillary molars were examined using CBCT images. The vertical relationship of each root with the maxillary sinus was classified into four types on CBCT cross-sectional images. The distance between the sinus floor and root and the bone thickness between the root and alveolar cortical plate were measured. Results: In the buccal roots of the maxillary molars, a root protruding into the sinus occurred most frequently. A root projecting laterally along the sinus cavity was most common in the palatal roots of the maxillary first molars. The mesiobuccal roots of the maxillary second molar were closest to the sinus. The mesiobuccal roots of the first molars were closest to the cortical plate. Conclusion: The relationship between the roots of the maxillary molars and the sinus differed between the buccal and palatal roots. A root protruding into the sinus occurred more frequent in the buccal roots of the maxillary molars. The mesiobuccal root of the maxillary second molar was closest to the maxillary sinus floor and farthest from the alveolar cortical plate.

Disrupted Association Between Empathy and Brain Structure in Attention-Deficit/Hyperactivity Disorder

  • Lee, Jeonghwan;Son, Jung-Woo;Kim, Siekyeong;Kim, Ji-eun;Chung, Seungwon;Ghim, Hei-Rhee;Lee, Sang-Ick;Shin, Chul-Jin;Ju, Gawon
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.32 no.4
    • /
    • pp.129-136
    • /
    • 2021
  • Objectives: To investigate the relationship between brain structure and empathy in early adolescents with attention-deficit/hyperactivity disorder (ADHD). Methods: Nineteen early adolescents with ADHD and 20 healthy controls underwent 3T MRI. All the participants were assessed for different aspects of empathy using measures including the Interpersonal Reactivity Index and Empathy Quotient. Cortical thickness and subcortical structural volume based on T1-weighted scans were analyzed using FreeSurfer. Results: Cognitive empathy (t=-2.52, p=0.016) and perspective taking (t=-2.10, p=0.043) were impaired in the ADHD group compared with the control group. The cluster encompassing the left posterior insular, supramarginal, and transverse temporal cortices [cluster-wise p-value (CWP)=0.001], which are associated with emotional empathy, was significantly smaller in the ADHD group, and the volume of the left nucleus accumbens was greater than that of the control group (F=10.12, p=0.003, effect size=0.22). In the control group, the left superior temporal (CWP=0.002) and lingual cortical (CWP=0.035) thicknesses were positively associated with cognitive empathy, while the right amygdala volume was positively associated with empathic concern (Coef=14.26, t=3.92, p=0.001). However, there was no significant correlation between empathy and brain structure in the ADHD group. Conclusion: The ADHD group had a smaller volume of the cortical area associated with emotional empathy than the control group, and there was no brain region showing significant correlation with empathy, unlike in the control group.

The validation of Periotest values for the evaluation of orthodontic mini-implants' stability (즉시 부하 교정용 미니임플랜트의 안정성 평가를 위한 Periotest$^{(R)}$의 유효성)

  • Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.167-175
    • /
    • 2010
  • Objective: The aim of this study was to validate the Periotest values for the prediction of orthodontic mini-implants' stability. Methods: Sixty orthodontic mini-implants (7.0 mm $\times$ $\emptyset1.45$ mm; ACR, Biomaterials Korea, Seoul, Korea) were inserted into the buccal alveolar bone of 5 twelve month-old beagle dogs. Insertion torque (IT) and Periotest values (PTV) were measured at the installation procedure, and removal torque (RT) and PTV were recorded after 12 weeks of orthodontic loading. To correlate PTV with variables, the cortical bone thickness (mm) and bone mineral density (BMD) within the cortical bone and total bone area were calculated with the help of CT scanning. Results: The BMD and cortical bone thickness in mandibular alveolus were significantly higher than those of the maxilla (p < 0.05). The PTV values ranged from -3.2 to 4.8 for 12 weeks of loading showing clinically stable mini-implants. PTV at insertion was significantly correlated with IT (-0.51), bone density (-0.48), cortical bone thickness (-0.42) (p < 0.05) in the mandible, but showed no correlation in the maxilla. PTV before removal was significantly correlated with RT (-0.66) (p < 0.01) in the mandible. Conclusions: These results show that the periotest is a useful method for the evaluation of mini-implant stability, but it can only be applied to limited areas with thick cortical and high density bone such as the mandible.

A Study on Biomimetic Composite for Design of Artificial Hip Joint (인공 관절 설계를 위한 바이오미메틱 복합재료에 관한 연구)

  • 김명욱;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.234-238
    • /
    • 1999
  • This study suggests the design of the functionally gradient composite, [0/90/0/core]$_s$ cross-ply laminate, to prevent stress concentration induced from the difference of rigidity between the bone and the artificial hip joint and to reinforce the wear property of the surface and the expectation of their mechanical properties. First, the four-point bending test is done about wet bones and dry bones to know the mechanical properties of the cortical bones. In result, the wet bone shows the viscoelastic behavior and the dry bone shows the elastic behavior. Moreover, we expect the properties of the proposed gradient composites as a function of carbon fiber volume fraction in each layer to apply Halpin-Tsai equation, CLPT(classical laminate plate theory), and Bernoulli beam theory etc. and decide the thickness ratio of each lamina in order to match Young's modulus of the anisotropic cortical bone with the proposed gradient composites.

  • PDF

STUDY OF MAXILLARY CORTICAL BONE THICKNESS FOR SKELETAL ANCHORAGE SYSTEM IN KOREAN (Skeletal Anchorage System의 식립을 위한 한국인 악골의 피질골 두께에 대한 연구)

  • Kim, Ji-Hyuck;Joo, Jae-Yong;Park, Young-Wook;Cha, Bong-Kuen;Kim, Soung-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.249-255
    • /
    • 2002
  • Recently, Skeletal Anchorage System (SAS) has been focused clinically with the view point that it could provide the absolute intraoral anchorage. First, it began to be used for the patient of orthognathic surgery who had difficulty in taking intermaxillary fixation due to multiple loss of teeth. And then, its uses have been extended to many cases, the control of bone segments after orthognathic surgery, stable anchorage in orthodontic treatment, and anchorage for temporary prosthesis and so on. SAS has been developed as dental implants technique has been developed and also called in several names; mini-screw anchorage, micro-screw anchorage, mini-implant anchorage, micro-implant anchorage (MIA), and orthosystem implant etc. Now many clinicians use SAS, but the anatomical knowledges for the installed depth of intraosseous screws are totally dependent on general experiences. So we try to study for the cortical thickness of maxilla and mandible in Korean adults without any pathologic conditions with the use of Computed Tomography at the representative sites for the screw installation.

INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY (임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향)

  • Oh, Gap-Yong;Park, Sung-Hwa;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

Three-dimensional evaluation of lingual split line after bilateral sagittal split osteotomy in asymmetric prognathism

  • Song, Jae Min;Kim, Yong Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.11-16
    • /
    • 2014
  • Objectives: The aim of this study was to evaluate the pattern of lingual split line when performing a bilateral sagittal split osteotomy (BSSO) for asymmetric prognathism. This was accomplished with the use of cone-beam computed tomography (CBCT) and three-dimensional (3D) software program. Materials and Methods: The study group was comprised of 40 patients (20 males and 20 females) with asymmetric prognathism, who underwent BSSO (80 splits; n=80) from January 2012 through June 2013. We observed the pattern of lingual split line using CBCT data and image analysis program. The deviated side was compared to the contralateral side in each patient. To analyze the contributing factors to the split pattern, we observed the position of the lateral cortical bone cut end and measured the thickness of the ramus that surrounds the mandibular lingula. Results: The lingual split patterns were classified into five types. The true "Hunsuck" line was 60.00% (n=48), and the bad split was 7.50% (n=6). Ramal thickness surrounding the lingual was $5.55{\pm}1.07$ mm (deviated) and $5.66{\pm}1.34$ mm (contralateral) (P =0.409). The position of the lateral cortical bone cut end was classified into three types: A, lingual; B, inferior; C, buccal. Type A comprised 66.25% (n=53), Type B comprised 22.50% (n=18), and Type C comprised 11.25% (n=9). Conclusion: In asymmetric prognathism patients, there were no differences in the ramal thickness between the deviated side and the contralateral side. Furthermore, no differences were found in the lingual split pattern. The lingual split pattern correlated with the position of the lateral cortical bone cut end. In addition, the 3D-CT reformation was a useful tool for evaluating the surgical results of BSSO of the mandible.