• Title/Summary/Keyword: cortical thickness

Search Result 163, Processing Time 0.02 seconds

MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION (임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구)

  • Park, Ju-Jin;Lee, Young-Soo;Paik, Doo-Jin;Park, Won-Hee;Yoo, Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.

Computer programme to assess mandibular cortex morphology in cases of medication-related osteonecrosis of the jaw with osteoporosis or bone metastases

  • Ogura, Ichiro;Kobayashi, Eizaburo;Nakahara, Ken;Haga-Tsujimura, Maiko;Igarashi, Kensuke;Katsumata, Akitoshi
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.281-286
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the morphology of the mandibular cortex in cases of medication-related osteonecrosis of the jaw (MRONJ) in patients with osteoporosis or bone metastases using a computer programme. Materials and Methods: Fifty-four patients with MRONJ (35 with osteoporosis and 19 with bone metastases) were examined using panoramic radiography. The morphology of the mandibular cortex was evaluated using a computer programme that scanned the mandibular inferior cortex and automatically assessed the mandibular cortical index (MCI) according to the thickness and roughness of the mandibular cortex, as follows: normal (class 1), mildly to moderately eroded (class 2), or severely eroded (class 3). The MCI classifications of MRONJ patients with osteoporosis or bone metastases were evaluated with the Pearson chi-square test. In these analyses, a 5% significance level was used. Results: The MCI of MRONJ patients with osteoporosis(class 1: 6, class 2: 15, class 3: 14) tended to be higher than that of patients with bone metastases(class 1: 14, class 2: 5, class 3: 0)(P=0.000). Conclusion: The use of a computer programme to assess mandibular cortex morphology may be an effective technique for the objective and quantitative evaluation of the MCI in MRONJ patients with osteoporosis or bone metastases.

A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

  • Kang, In-Ho;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.190-195
    • /
    • 2011
  • PURPOSE. This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS. As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Br${\aa}$nemark System$^{(R)}$ Mk III TiUnite$^{TM}$, Straumann Standard Implant SLA$^{(R)}$, and Astra Tech Microthread$^{TM}$-OsseoSpeed$^{TM}$) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS. In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Br${\aa}$nemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION. The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level.

The effect of varying peripheral bone structure and bone density on the occlusal stress distribution of human premolar regions (사람 소구치부위에서 주위골의 구조 및 밀도변화가 교합력에 의한 치아의 응력분포에 미치는 영향)

  • Suh, Ye-Joon;Shim, June-Sung;Lee, Keun-Woo;Chung, Moon-Kyu;Lee, Ho-Yong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.7-15
    • /
    • 2003
  • This study used FEM(Finite Element method) based on micro-CT images to see the effects of occlusal force distribution with varying bone density and structure. the mandibular premolar region from human cadaver, thickness of 10mm was imaged using micro-CT. the cross sectional images were taken every $10{\mu}m$. these were reconstructed and the longitudinal image at the mid point of mesiodistal of the speciman was obtained for the specimen for the FEM. The stress disribution produced by a vertical force at 100N and 100N horizontal were analyzed by MSC Nastran FEM Package. according to the result of this study the occlusal force distribution depends on the structure of cancellus bone and for further information on the occlusal force distribution on the tooth and the surrounding structure requires further studies on cancellus bone structure. CEJ of all model show the highest peak and region whice meet teeth and bone show second high peak. Original model and cortical bone add model show different stress distribution. Stress distribution changed according to bone structures and densities.

THE EFFECT OF A CHITOSAN COATING OF DENTAL IMPLANT ON THE SHOCK ABSORPTION UNDER IMPACT TEST (키토산으로 표면처리된 인공치아의 충격전달에 관한 연구)

  • Kim, Ki-Hong;Lee, Yong-Chan;Cho, Byoung-Ouck;Choi, Kui-Won;Kwon, Ick-Chan;Bae, Tae-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.1
    • /
    • pp.9-14
    • /
    • 2001
  • With the object of providing a temporary artificial periodonal ligament-like membrane around the dental implant, 10 Branemark type implants were coated with commercially available chitosan(Fluka Co., Buchs, Switzerland) which has a molecular weight of 70,000 and 80% deacetylation degree. Once this bioactive hydrophillic polymer(chitosan) contacts with blood or wound fluids, it becomes swollen and penetrates into the adjacent cancellous bone. Thus the interface between implant and surrounding bone is completely filled with chitosan. This tight junction in early healing phase enhances primary stability. The chitosan coated dental implants were implanted into the fresh patella bones from porcine knees, since the thickness of cortical bone is relatively even and their cancellous structure is homogenous. To test the shock absorbing effect, 1mm delta-rogette strain gage was installed behind the implant. The results showed 1. The principal strain peak value directed to the impact of coated implant was 0.064 0.018(p<0.05) and that of uncoated implant was 0.095(0.032 p<0.05). 2. The peak time delay of coated implant was 0.056sec(0.011 p<0.05) and that of uncoated implant was 0.024sec(0.009 p<0.05). It can be reasoned from this results that the chitosan coating has a shock absorbing effect comparable with a temporary artificial periodontal ligament.

  • PDF

One Step Measurements of hippocampal Pure Volumes from MRI Data Using an Ensemble Model of 3-D Convolutional Neural Network

  • Basher, Abol;Ahmed, Samsuddin;Jung, Ho Yub
    • Smart Media Journal
    • /
    • v.9 no.2
    • /
    • pp.22-32
    • /
    • 2020
  • The hippocampal volume atrophy is known to be linked with neuro-degenerative disorders and it is also one of the most important early biomarkers for Alzheimer's disease detection. The measurements of hippocampal pure volumes from Magnetic Resonance Imaging (MRI) is a crucial task and state-of-the-art methods require a large amount of time. In addition, the structural brain development is investigated using MRI data, where brain morphometry (e.g. cortical thickness, volume, surface area etc.) study is one of the significant parts of the analysis. In this study, we have proposed a patch-based ensemble model of 3-D convolutional neural network (CNN) to measure the hippocampal pure volume from MRI data. The 3-D patches were extracted from the volumetric MRI scans to train the proposed 3-D CNN models. The trained models are used to construct the ensemble 3-D CNN model and the aggregated model predicts the pure volume in one-step in the test phase. Our approach takes only 5 seconds to estimate the volumes from an MRI scan. The average errors for the proposed ensemble 3-D CNN model are 11.7±8.8 (error%±STD) and 12.5±12.8 (error%±STD) for the left and right hippocampi of 65 test MRI scans, respectively. The quantitative study on the predicted volumes over the ground truth volumes shows that the proposed approach can be used as a proxy.

TREATMENT OF PALATAL ABSCESS OF ODONTOGENIC ORIGIN IN CHILDREN: CASE REPORTS (소아에서 발생한 치성 기원 구개 농양의 치험례)

  • Ryu, Jae-Ryang;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.4
    • /
    • pp.421-426
    • /
    • 2011
  • Most of the intraoral infections origin in odontogenic infection. Odontogenic infection spreads out along the least resistant path. In maxilla, the thickness between periapical area and cortical bone is narrower on the buccal side than the palatal side. So infection usually spreads out along the buccal side rather than the palatal side. The failure of root canal treatment more frequently occurs on the buccal root compared to the palatal root. So the palatal abscess is rarer than the buccal abscess. It is difficult to differential diagnosis palatal abscess from salivary gland tumors, benign neural tumors and cysts on the palate. Therefore, when the palatal swelling is observed in children, you need to prevent the systemic spread of infection by early diagnosis of the odontogenic palatal abscess. In these cases, the patient who complained of the pain in deciduous teeth and the palatal swelling was diagnosed with odontogenic palatal abscess. The patient was treated with extraction and antibiotic medication. The palatal abscess was resolved, and we report after treatments.

Effects of Laennec.N.HO (Hominis placenta.Cervi pontotrionum cornu.Carthami semen) aqua-acupuncture on the ovariectomized osteoporotic Rats (자하거(紫河車).녹용(鹿茸).홍화자(紅花子) 약침액(藥鍼液)이 난소적출(卵巢摘出)로 골다공증(骨多孔症)을 유도(誘導)한 흰쥐에 미치는 영향(影響))

  • Jang, Su-Jin;Lee, Chang-Hyun;Yook, Tae-Han
    • The Journal of Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.5-18
    • /
    • 1998
  • The purpose of this study was to determine the effects of aqua-acupuncture of Laennec N HO (Hominis placenta Cervi pontotrichum cornu Carthami semen). on trabecular area and physiological change in ovariectomized osteoporotic rats. This experiment was performed to .investigate an antiosteoporosis. effects of Laennec N HO(Hominis placenta Cervi pontotrichum cornu Carthmi semen) aqua-acupuncture on the osteoporosis induced by both ovariectomy in Rats. So rats were divided into Sham group and OVX group. OVX groups were divided into control group, Exp. I group, Exp II group and Exp III group). The Ratios of trabecular area seen in ephiphysis and diaphysis of tibia and lumbar vertebral body and physiological change were as follows. 1. In the proximal ephiphysis of tibia, Exp I II III groups were significantly increased compared to that in control group (p<0.05). 2. In the diaphysis of tibia, Exp III group were significantly increased compared to that in control group (p<0.05). 3. In the first lumbar vertebral body, Exp II group were significantly increased compared to that in control group. 4. In the cortical thickness index of tibia, Exp III III groups were significantly increased compared to that in control group. 5. Osteoca1cin was increased in the Exp II group than those of other Experiment groups and control group, and Phosphorus was decreased in the Exp I II group than that in control group, But a significant difference was not seen. GOT, GPT and Alkaline phosphatase were decreased in all Experiment groups than that in control group. But a significant difference was not seen. From the above results, it might be suggested that aqua-acupuncture Laennec N HO(Hominis placenta Cervi pontotrichum cornu Carthami semen) prevented the increase in bone turnover and the decrese in bone mass induced by OVX in rats.

  • PDF

Evaluation of the Efficacy of Zoledronic Acid and Amifostine on Radiation-induced Bone Loss in Mice

  • Kim, Jinwook;Lee, Sueun;Kang, Sohi;Moon, Changjong;Kim, Jong-Choon;Jung, Uhee;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.253-259
    • /
    • 2016
  • Background: This study investigated the effects of zoledronic acid (ZA) on radiation-induced bone loss in C3H/HeN mice. Materials and Methods: C3H/HeN mice were divided into sham control and three irradiated groups (3 Gy, gamma ray). The irradiated mice were treated for 12 weeks with vehicle, amifostine (intraperitoneal injection), or ZA (subcutaneous injection). Grip strength, uterus weight, and serum alkaline phosphatase (ALP), and tartrate-resistant acid phosphatase (TRAP) levels were measured. Tibiae were analyzed using micro-computed tomography. Results and Discussion: Treatment of ZA ($100{\mu}g{\cdot}kg^{-1}{\cdot}week^{-1}$) significantly preserved trabecular bone volume, trabecular thickness, trabecular number, trabecular separation, bone mineral density of proximal tibia metaphysic, and cortical bone volume, but did not alter the uterus weight of the mice. The administration of ZA for 12 weeks lowered serum ALP and TRAP levels in irradiated mice, suggesting that ZA can reduce the bone turnover rate in mice. No differences were apparent between the amifostine-treated group and the irradiation control group. Conclusion: The results indicate that ZA can prevent radiation-induced bone loss in mice.

MORPHOMETRIC STUDY OF SCAPULAR LATERAL BORDER FOR INSTALLATION OF DENTAL IMPLANT. (치과용 임프란트 매식을 위한 견갑골외연의 형태학적 연구)

  • Lee, Jong-Ho;Jung, Soong-Ryong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.3
    • /
    • pp.231-238
    • /
    • 1995
  • The scapular flap, described by dos Santos in 1986, has been used successfully for the reconstruction of a variety of defects of oro-mandible. Some have defined the gross and vascular anatomy of the lateral border of the scapula, yet useful anatomical information and a complete description of area and contour of each cut surface of lateral border of scapula, which is very important for esthetic and functional reconstruction using dental implants, are missing. These prompted us to clarify the cross-sectional area of lateral border of scapula. Twenty three scapulas of 15 fixed adult Caucasian cadavers were sectioned in every 1cm interval along the lateral border of scapular, and the metric relations and the shape of cut surface were assessed. The lateral border of the scapula, consisting of cortico-cancellous bone measuring $7.86{\pm}0.97mm$ in width, $19.6{\pm}2.86mm$ in height and $12{\pm}1.78cm$ in length, could be harvested as an osteocutaneous scapular flap or as a single vascularized bone flap. The mean thickness of cortical bone of lateral, medial, dorsal and costal surface was $0.46{\pm}1.48mm$, $1.78{\pm}1.34mm$, $1.54{\pm}1.11mm\;and\;1.35{\pm}0.87mm$, respectively. So we have thought that all scapular transplants could be supported osseointegrated implants for fixation of dental prosthesis.

  • PDF