• Title/Summary/Keyword: corrugated type

Search Result 109, Processing Time 0.025 seconds

Radially Corrugated Circular Microstrip Patch Antenna for Miniaturization (소형화를 위한 방사 주름 원형 마이크로스트립 패치 안테나)

  • 이성민;김종래;우종명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1233-1238
    • /
    • 2003
  • In this paper, radially corrugated circular-type microstrip patch antenna was devised and manufactured for GPS (center frequency: 1.575 GHz). Radially corrugated circular-type microstrip patch antenna having radiational corrugation-patch contributed to add size reduction ratio by lowering the resonant frequency because the edge current also has the extended and perpendicular path. As a result, radially corrugated circular-type microstrip patch antenna has 28 % area reduction than planer circular-type patch antenna for linear polarization and 27.7 % area reduction than planer circular-type patch antenna for circular polarization. Radially corrugated circular-type microstrip patch antenna is suitable for miniaturized receive antenna for GPS which has the characteristic of gain 2.1 dBd, axiai ratio 1.3 dB, 2 dB axial bandwidth 15 MHz(0.9 %).

Experimental Study on the Heat Transfer Characteristics in Corrugated and Flat Plate Type Heat Exchanger (콜로게이트 열교환기와 평판형 열교환기의 열전달특성에 관한 실험적 연구)

  • Park, Jung-Hun;Jeong, Yong-Ki;Jeon, Chung-Hwan;Chang, Young-June;Lim, Hyeok
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.37-42
    • /
    • 2003
  • An experiment was performed to study heat transfer characteristics between corrugated heat exchanger and flat plate type one. While heat capacity(13.86kW) was provided constantly and the flow speed was varied from 2.8 to 17.9m/s, The temperature and the pressure drop were measured. Furthermore, Heat transfer coefficient, Colburn factor and Nusselt number were calculated using them. With increase of the flow speed for both exchangers, the coefficient and the pressure drop increased, but Colburn factor decreased. The coefficient, pressure drop and Colburn factor of the corrugated type were all higher than those of the flat one, which is due to the flow interruption with recirculation and reattachment of the corrugated type. The empirical correlations of Nusselt number were suggested for the tested two heat exchangers.

  • PDF

Numerical investigation of a plate-type steam generator for a small modular nuclear reactor

  • Kang, Jinhoon;Bak, Jin-Yeong;Lee, Byung Jin;Chung, Chang Kyu;Yun, Byongjo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3140-3153
    • /
    • 2022
  • A numerical feasibility study was conducted to investigate the thermal-hydraulic characteristics of a steam generator with corrugated plates for a small modular reactor. Accordingly, a one-dimensional thermal-hydraulic analysis code was developed based on the existing state-of-the-art thermal-hydraulic models and correlations for corrugated plate heat exchangers. Subsequently, the pressure loss, heat transfer, and instability characteristics of the steam generator with corrugated plates were investigated according to the chevron angle and mass flux. Additionally, the characteristics of rectangular and disk-type corrugated plate steam generators with equivalent heat transfer areas were analyzed. The steam generator with disk-type corrugated plates exhibited better performance in terms of pressure loss and heat transfer rate than the rectangular type. In addition, when the mass flux decreased from the onset of boiling points, reverse gradients of the total pressure change were observed in both types. Thus, it was confirmed that Ledinegg instability could occur in the steam generator with corrugated plates. However, it was dependent on the chevron angle, and the optimal chevron angle to minimize instability was 45° under the conditions of the present analysis.

Characteristics of Fluid Flow in the Fluidized Bed Shell and Tube Type Heat Exchanger with Corrugated Tubes

  • Ahn Soo Whan;Bae Sung Taek;Kim Myoung Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.198-205
    • /
    • 2004
  • An experimental study was carried on the characteristics of fluid flow and heat transfer in a fluidized bed shell-and-tube type heat exchanger with corrugated tubes. Seven different solid particles having same volume were circulated in the tubes. The effects of vari­ous parameters such as water flow rates, particle geometries and materials, and geometries of corrugated tubes on relative velocities and drag coefficients were investigated. The present work showed that the drag force coefficients of particles in the corrugated tubes were usually lower than those in the smooth tubes, meanwhile the relative velocities between particles and water in the corrugated tubes were little higher than those in the smooth tubes except the particles of glasses.

Fluid Flow in the Fluidized Bed Shell and Tube Type Heat Exchanger with Corrugated Tubes (파형관 튜브가 있는 순환유동층 원통다관형 열교환기 내의 유체유동)

  • 안수환;이병창;배성택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.406-412
    • /
    • 2003
  • An experimental study was carried on the characteristics of fluid flow and heat transfer in a fluidized bed shell-and-tube type heat exchanger with corrugated tubes. Seven different solid particles having same volume were circulated in the tubes. The effects of various parameters such as water flow rates, particle geometries and materials, and geometries of corrugated tubes on relative velocities and drag coefficients were investigated. The present work showed that the drag force coefficients of particles in the corrugated tubes were usually lower than those in the smooth tubes, meanwhile the relative velocities between particles and water in the corrugated tubes were little higher than those in the smooth tubes except the glass.

Heat Transfer in the Vertical Type Fluidized Bed Heat Exchanger with Corrugated Tubes (파형관을 갖는 수직형 순환유동층 열교환기의 열전달)

  • Ahn Soo Whan;Bae Sung Taek;Kim Myung Ho;Lee Byung-Chang;Lee Yoon Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1149-1155
    • /
    • 2004
  • An experimental study was performed to investigate the characteristics of heat transfer in a vertical type fluidized bed shell-and-tube type heat exchanger with corrugated tube. Seven different solid particles having the same volume were circulated in the heat of exchanger. The effects of various parameters such as water flow rates, particle geometries, materials, and corrugated tube geometries were investigated. The present work showed that the higher thermal capacities of materials and the geometries closer to the spherical one have higher heat transfer performances. In addition, heat transfer coefficients in the corrugated tubes were a little higher than those in the smooth tubes.

Structural Design and Manufacturing of Corrugated Plate for Plate-Type Heat Exchanger (연속 주름구조를 가진 전열판의 기계적 건전성 확보를 위한 형상 설계 및 제작)

  • Yu, Jae Hyun;Bae, Won Byong;Park, Sang Hu;Cho, Jong Rae;Jeong, Ho Seung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.3
    • /
    • pp.199-205
    • /
    • 2016
  • A thin sheet of metal with corrugated structures has been utilized in various devices: heat exchangers, separators in fuel cells, and many others. However, it is not easy to fabricate thin corrugated structures using a single-step stamping process due to their geometrical complexity. To solve this problem, firstly, a plate type heat exchanger was redesigned to attain the optimal value of aspect ratio and the optimal shape of corrugated structures for the actual loading conditions. A forming analysis of the corrugated plate was then carried out to determine the process parameters. From this work, the optimal value of aspect ratio was found to be 4.6. In addition, the process parameters of heat exchanger forming were optimized using the optimal value of aspect ratio, and the analytical results were evaluated through experiments. The results obtained indicated good agreements between them.

Effect of Vibration during Distribution Process on Compression Strength of Corrugated Fiberboard Boxes for Agricultural Products Packaging (농산물 포장용 골판지상자의 수송 중 진동에 의한 압축강도 변화)

  • Shin, Joon Sub;Kim, Jongkyoung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.27 no.2
    • /
    • pp.91-100
    • /
    • 2021
  • Agricultural corrugated fiberboard packaging boxes frequently experience damage due to loading and unloading, vibration during transport, and shock by dynamic distribution condition change. This study was carried out to estimate effect of vibration during distribution process on compression strength of corrugated fiberboard boxes for agricultural products. In order to identify the degradation caused by vibration, after box packaging the agricultural products(tangerine or cucumber), the natural frequencies of the packaging boxes were measured by varying the relative humidity(50, 70 and 90%) at 25℃ temperature. Various types of corrugated fiberboard boxes were packed with tangerines and cucumbers, and the PSD plot vibration tests were conducted by utilizing the actual vibration recording results of the Gyeongbu Expressway section between Seoul and Gimcheon. As a result of the experiment, the decrease in compression strength of the box was relatively low in DW-AB, and the decrease in compression strength of the SW-A 0201(RSC) type box was the highest at 20.49%. In particular, both SW-A and DW-AB showed low compression strength degradation rates for open folder type boxes. The moisture content varies depending on the type of the box or agricultural products, and the enclosed 0201(RSC) type box was generally higher than the open folder or bliss type box, which is believed to be the reason for the decrease in compression strength of RSC type box due to humidity. By the agricultural product, the percentage of decrease in compression strength of box packed with cucumbers was especially high.

Design of monopulse feeder using corrugated E-plane horn (E-평면 컬러게이트 혼을 이용한 모노펄스 급전기 설계)

  • 이주형;남상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.8
    • /
    • pp.2099-2108
    • /
    • 1996
  • The performance of the E-plane monopulse feeder is shown to e improved by using corrugated horn and multimode design. The proposed multimode corrugated horn is analyzed by the mode matching technique. an E-plane monopulse feeding horn is designed and fabricated to show the performance of the multimode corrugated horn. The experiment agrees quite well with the thoretical analysis. The results can be used in the design of monopulse type tracking radar antenna.

  • PDF

Electromagnetic Interference Shielding Effectiveness of a Corrugated Rectangular Waveguide for an Open-Type Microwave Conveyor-Belt Dryer (개방형 마이크로파 컨베이어 벨트 건조기의 요철 직사각형 도파관 차폐효과)

  • Kim, Sung-Yeon;Bae, Sang-Hyeon;Lee, Wang-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.424-432
    • /
    • 2018
  • We herein analyze and study the shielding effectiveness characteristic of an open conveyor-belt-type microwave dryer that is widely used in industry. In particular, the electromagnetic wave leakage problem of the open-type conveyor belt dryer using a general-purpose 2.45-GHz magnetron was improved by applying the corrugated rectangular waveguide. We conducted the electromagnetic simulation of the optimal shielding effectiveness characteristic with regard to the proposed waveguide structure to analyze the attenuation characteristics of the corrugated rectangular waveguide. To verify the shielding effectiveness characteristic of the fabricated corrugated rectangular waveguide by IEEE standard 299, we achieved the shielding effectiveness of more than 30 dB in the practical microwave dryer with the proposed corrugated rectangular waveguide.