• Title/Summary/Keyword: corrosion pipeline

Search Result 199, Processing Time 0.021 seconds

Investigation for Earth Resistance and Leakage Current of D/L (배전선로 접지저항 및 누설전류 실태조사)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Ha, Y.C.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.379-381
    • /
    • 2003
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. This causes induced voltages on underground metallic pipelines due to the power line currents. This could cause AC corrosion in the pipeline, which could in turn lead to disastrous accidents, such as gas explosion or oil leakage. This paper investigates for the limitation of induced voltage on the buried metal structures which is used in the inside and outside of the country. And then we measure the earth resistance and leakage current of 22.9kV distribution lines and pipe to soil potential of near pipelines in Seoul Korea. Hereby we can see the leakage current flowing through the earthing electrode have an effect on near pipelines.

  • PDF

A study on the condition assessment of large diameter water valves using non-destructive technologies (비파괴 기술을 이용한 대구경 수도용 밸브의 상태평가에 관한 연구)

  • Ho-Min Lee;Hyun-yong Choi;Suwan Park;Tae-min Oh;Chae-Min Kim;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.215-229
    • /
    • 2023
  • In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.

Study on Probabilistic Analysis for Fire·Explosion Accidents of LPG Vaporizer with Jet Fire (Jet Fire를 수반한 국내외 LPG 기화기의 화재·폭발사고에 관한 확률론적 분석에 관한 연구)

  • Ko, Jae-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.31-41
    • /
    • 2012
  • This study collected 5,100 cases of gas accident occurred in Korea for 14 years from 1995 to 2008, established Database and based on it, analyzed them by detailed forms and reasons. As the result of analyzing the whole city gas accidents with Poisson analysis, the item of "Careless work-Explosion-Pipeline' showed the highest rate of accidents for the next 5 years. And, "Joint Losening and corrosion-Release-Pipeline" showed the lowest rate of accident. In addition, for the result of analyzing only accidents related to LPG vaporizer, "LPG-Vaporizer-Fire" showed the highest rate of accident and "LPG-Vaporizer-Products Faults" showed the lowest rate of accident. Also, as the result of comparing and analyzing foreign LPG accident accompanied by Jet fire, facility's defect which is liquid outflow cut-off device and heat exchanger's defect were analyzed as the main reason causing jet fire, like the case of Korea, but the number of accidents for the next 5 years was the highest in "LPG-Mechanical-Jet fire" and "LPG-Mechanical-Vapor Cloud" showed the highest rate of accidents. By grafting Poisson distribution theory onto gas accident expecting program of the future, it's expected to suggest consistent standard and be used as the scale which can be used in actual field.

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(I) (전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(I))

  • Kang, Young-June;Park, Nak-Kyu;Ryu, Won-Jae;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.393-401
    • /
    • 2002
  • Pipelines in power plants, nuclear facilities and chemical industries are often affected by corrosion effects. It is important to inspect the internal defects in pipelines in oder to guarantee safe operational condition. We have taken relatively much time, cost and manpower to use conventional NDT methods because these methods are contact measuring methods. In this paper, we used digital shearography, a laser-based optical method which allows full-field measurement of surface displacement derivatives. This method has many advantages in practical use, such as low sensitivity to environmental noise, simple optical configuration and real time measurement. The experiment was performed with pressure vessels which has different internal cracks and detected internal cracks in the pressure vessels at a real time using phase shifting method.

The Component Analysis of Foreign Substance Occurred in Water Distribution Networks (상수관망에서 발생하는 이물질의 성분분석)

  • Choi, Min-Ah;Kim, Do-Hwan;Bae, Chul-Ho;Lee, Doojin;Choi, Doo Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.614-623
    • /
    • 2014
  • Customers water quality complaints by foreign substance in local water service can be able to call the main cause bring the distrust for tap water and inhibiting the rate of drinking water. In this study, foreign substances were collected in the target region. Foreign objects were subjected to qualitative and quantitative analysis of compounds and elements components to reveal the cause of detection. Also, resolve the complaints by foreign substance and improve the reliability for tap water providing high quality water supply scheme. Collected substances at the water quality complaint area were included in inorganic compounds due to internal corrosion and aging pipeline, as well as organic compounds containing a large amount of carbon (C) and oxygen (O) component. To decide and reduce for foreign substance, objective assessment of pipe condition in target area was required.

Effects of flushing techniques on water quality at extremity with low chlorine residuals in drinking water distribution systems (수질 취약지역 및 관말에서 플러싱 적용 먹는물 수질 개선 효과)

  • Ko, Kyung-Hoon;Kweon, Ji-Hyang;Kim, In-Ja;Lim, Woo-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.313-324
    • /
    • 2011
  • Several complaints from consumers on red or turbid waters were often filed at the same places although various efforts were made to improve water quality in the drinking water plant. The red water problems were occurred due to corrosion of main water pipe, especially at extremity. The low concentrations of chlorine indicating poor water quality were detected at the problematic location. To solve the poor water quality at the extremity, flushing techniques, i.e., conventional flushing, unidirectional flushing, and continuous flushing, were recently practiced. In this study, effects of conventional flushing on water qualities were examined by comparing turbidity and residual chlorine before and after flushing. In addition, more detailed analyses on water qualities at the tap water were conducted to learn a reduction pattern during flushing. Five items from geographic information system of water distribution were used to obtain a relationship with water quality, washing duration or amounts of washing water. The flushing was effective to meet the National Drinking Water Quality Standard with simple and relatively short time operation. The key operational parameter in flushing was amounts of washing water which should be estimated based on water quality of the consumer's tap water. The positive relationship between the residual chlorine and pipe length implied that detention time in the pipeline was the main cause of the complaints. More experiments on effectiveness of flushing are needed to determine reasonable strategies of flushing.

Validation Study on Processing Grip Part of Tensile Specimen Acquired from Corroded Pipeline (부식이 존재하는 기존 노후 관로에서 인장 시편 가공 시 그립 가공 타당성에 대한 연구)

  • Nam, Young Jun;Kim, Jeong Hyun;Bae, Cheol Ho;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.191-195
    • /
    • 2020
  • In this work, tensile tests, one of the most common test method to assess the condition of a corroded pipe, were conducted. According to ASTM E8 method, the use of flat or curved uni-axial tension test is allowed under the recommendation with the usage of grips corresponding to a curvature of the pipe. However, this method is not for corroded specimen. Furthermore, in the case of performing the multiple tensile tests with various curvatures, it is desirable not to produce zigs that fit each curvatures, if merely processing the specimen grip with curvature into the flat grip can show almost identical tensile behavior. Therefore, various tension simulations were conducted first to check if there exist any differences. Also, experiments on corroded tensile specimen were conducted and compared with the FEM simulation that reflects the actual geometry acquired from the 3D scanner.

A Study on the Turbidity Estimation Model Using Data Mining Techniques in the Water Supply System (데이터마이닝 기법을 이용한 상수도 시스템 내의 탁도 예측모형 개발에 관한 연구)

  • Park, No-Suk;Kim, Soonho;Lee, Young Joo;Yoon, Sukmin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Turbidity is a key indicator to the user that the 'Discolored Water' phenomenon known to be caused by corrosion of the pipeline in the water supply system. 'Discolored Water' is defined as a state with a turbidity of the degree to which the user visually be able to recognize water. Therefore, this study used data mining techniques in order to estimate turbidity changes in water supply system. Decision tree analysis was applied in data mining techniques to develop estimation models for turbidity changes in the water supply system. The pH and residual chlorine dataset was used as variables of the turbidity estimation model. As a result, the case of applying both variables(pH and residual chlorine) were shown more reasonable estimation results than models only using each variable. However, the estimation model developed in this study were shown to have underestimated predictions for the peak observed values. To overcome this disadvantage, a high-pass filter method was introduced as a pretreatment of estimation model. Modified model using high-pass filter method showed more exactly predictions for the peak observed values as well as improved prediction performance than the conventional model.