• Title/Summary/Keyword: corrosion of steel bar

Search Result 141, Processing Time 0.033 seconds

Flexural Behavior of Concrete Beams Reinforced with CFRP rebars (CFRP Rebar로 보강한 콘크리트 보의 휨 거동)

  • Lee, Young-Hak;Won, Dong-Min;Kim, Min-Sook;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • To address the problems caused by the corrosion of steel rebar, active research has recently been carried out on members where fiber-reinforced polymer (FRP) is used in place of rebar. As FRP bar is highly brittle and has a low modulus of elasticity, further research is needed on the evaluation of serviceability, in other words on the deflection of flexural concrete members reinforced with FRP rebars. Taking the reinforcement ratio as a variable, this paper analyzes the flexural capacity of concrete beams reinforced with CFRP rebar. The test results of specimens reinforced with CFRP rebar show an increase in stiffness and resisting force along with an increase in the reinforcement ratio. A reinforcement ratio of about 1.3 is needed for the member reinforced with CFRP rebar to show same section property of a steel member. Through a comparison for the value of an effective moment of inertia, the equation suggested by Bischoff & Scanlon predicted values closest to the actual results.

Effect of Total Resistance of Electrochemical Cell on Electrochemical Impedance of Reinforced Concrete Using a Three-Electrode System (3전극방식을 활용한 철근 콘크리트의 교류임피던스 측정 시 전기화학 셀저항의 영향)

  • Khan, Md. Al-Masrur;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.82-92
    • /
    • 2022
  • This study aims to investigate the effect of total electrochemical cell resistance (TECR) on electrochemical impedance (EI) measurements of reinforced concrete (RC) by electrochemical impedance spectroscopy (EIS) using a three-electrode system. A series of experimental study is performed to measure electrochemical behavior of a steel bar embedded in a concrete cube specimen, with a side length of 200 mm, in various experimental conditions. Main variables include concrete dry conditions, coupling resistance between sensing electrodes and concrete surface, and area of the counter electrode. It is demonstrated that EI values remains stable when the compliant voltage of a measuring device is sufficiently great compared to the potential drop caused by TECR of concrete specimens. It is confirmed that the effect of the coupling resistance of TECR is far more influential than other two factors (concrete dry conditions and area of the counter electrode). The results in this study can be used as a fundamental basis for development of a surface-mount sensor for corrosion monitoring of reinforced concrete structures exposed to wet-and-dry cycles under marine environment.

The Condition Evaluation of Mortar Parts of Stupa of State Preceptor Jigwang from Wonju Beopcheonsa Temple Site by Half Cell Potential Measurement - with Focus on the Mortar Parts the RoofStone - (반전위 측정을 통한 원주 법천사지 지광국사탑 모르타르 복원부위 상태평가 연구 - 옥개석 모르타르 복원부위를 중심으로 -)

  • Lee, Tae Jong;Cho, Ha Jin;Park, Hee Jeong;Chae, Seung A
    • Journal of Conservation Science
    • /
    • v.34 no.6
    • /
    • pp.503-515
    • /
    • 2018
  • Stupa of State Preceptor Jigwang at Beopcheonsa temple site, Wonju, was conserved and restored in 1957. It was necessary to assess the degree of damage to the used mortar and to provide objective data on the necessity of its removal. Therefore, the HCP(half-cell potential) measurement used in concrete fields was applied. Multi-regression analysis of HCP data, following the rapid corrosion test of the roofstone mortar used by the rebar, resulted in a high correlation of HCP values(0.86), depending on the amount of corrosion and cover depth used for the steel bar. As a result, high correlation values(0.86) for the coefficients of determination were derived. The showed that the measurement of the wet conditions -431 to -663 mV on the roofstone indicated a corrosion damage rate of 90% or more after removal and restoration.

Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio (GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가)

  • You, Young-Jun;Park, Young-Hwan;Choi, Ji-Hun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.491-497
    • /
    • 2014
  • The corrosion of steel reinforcement in reinforced concrete bridge decks significantly affects the degradation of the capacity. Due to the advantageous characteristics such as high tensile strength and non-corrosive property, fiber reinforced polymer (FRP) has been gathering much interest from designers and engineers for possible usage as a alternative reinforcement for a steel reinforcing bar. However, its application has not been widespread, because there data for short- and long-term performance data of FRP reinforced concrete members are insufficient. In this paper, seven full-scale decks with dimensions of $4000{\times}3000{\times}240mm$ were prepared and tested to failure in the laboratory. The test parameter was the bottom reinforcement ratio in transverse direction. The decks were subjected to various levels of concentrated cyclic load with a contact area of $577{\times}231mm$ to simulate the vehicle loading of DB-24 truck wheel loads acting on the center span of the deck. It was observed that the glass FRP (GFRP) reinforced deck on a restraint girder is strongly effected to the level of the applied load rather than the bottom reinforcement ratio. The study results showed that the maximum load less than 58% of the maximum static load can be applied to the deck to resist a fatigue load of 2 million cycles. The fatigue life of the GFRP decks from this study showed the lower and higher fatigue performance than that of ordinary steel and CFRP rebar reinforced concrete deck. respectively.

Application of High-Performance Steels to Enhance the Punching Shear Capacity of Two-Way Slabs (2방향 슬래브의 펀칭전단성능 향상을 위한 고성능 철근의 적용)

  • Yang, Jun Mo;Shin, Hyun Oh;Lee, Joo Ha;Yoon, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • Two-way slabs reinforced with high-performance steels, which have several practical advantages of a reduction of congestion in heavily reinforced members, savings in the cost of labor and repair, the higher corrosion resistance, and a reduction of construction time, were constructed and tested. The influences of the flexural reinforcement ratio, concentrating the reinforcement in the immediate column region, and using steel fiber-reinforced concrete (SFRC) in the slab on the punching shear resistance and post-cracking stiffness were investigated, and compared with the punching shear test results of the slabs reinforced with conventional steels and GFRP bars. In addition, the strain distribution of flexural reinforcements and crack control were investigated, and the effective width calculating method for the average flexural reinforcement ratio was estimated. The use of high-performance steel reinforcement increased the punching shear strength of slabs, and decreased the amount of flexural reinforcements. The concentrating the top mat of flexural reinforcement increased the post-cracking stiffness, and showed better strain distribution and crack control. In addition, the use of SFRC showed beneficial effects on the punching shear strength and crack control. It was suggest that the effective width should be changed to larger than 2 times the slab thickness from the column faces.

An Experiemtnal Study on the Air Permeability Effect on Concrete Carbonation (콘크리트의 중성화에 영향을 미치는 투기성에 관한 실험적 연구)

  • 권영진;김무한;강석표;유재강
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.277-284
    • /
    • 2001
  • Hardened concrete contains pores of varying types and sizes, and therefore the transport of air through concrete can be considered. The rate of permeability will not only depends on the continuity of pores, but also on the moisture contents in concrete and finishing material on concrete. Also it knows that the durability of reinforced concrete structure is concerned with air permeability which effects on the carbonation occurred by invasion of CO2 gas and the corrosion of steel bar occurred by O$_2$. In this paper, the effects of curing conditions and finishing materials on carbonation and air permeability are investigated according to the accelerated carbonation test. As results, carbonation velocity and air permeability are effected by curing conditions and finishing materials, and air permeability coefficient is effected by moisture content. Also the relationship between carbonation velocity coefficients and air permeability coefficients has been quite well established.

The Chloride Ion Diffusivity of Ready-Mixed Concrete Depending on Specified Compressive Strength (레디믹스트 콘크리트의 설계기준 압축강도별 염소이온 확산특성)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.543-550
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforcing steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is higher than 35MPa in the concrete/building construction standard specification. Even though it has been proved that the concrete mixed with mineral admixture such as blast furnace slag and fly ash etc. have high strength and durability in previous researches, the beneficial informations are not applied to the codes. Ready-mixed concretes which usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC. For economical and reliable durability design, chloride ion diffusivity should be measured before applying to new building construction.

Long-Term Monitoring and Analysis of Changes in the Soil Layer on Dokdo (장기 모니터링을 통한 독도 자연사면의 토층 변화 분석)

  • Kyeong-Su Kim;Young-Suk Song;Dae-Seong Yun;Eunseok Bang
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.163-171
    • /
    • 2024
  • Changes in the soil layer on Dokdo are important both academically and with regard to sustainable conservation and utilization of the islands. Continuous investigation and observation are necessary, as the soil layer is essential to the growth of plants and, therefore, the islands' ecosystem. Such work was carried out for about 8 years using soil erosion measuring bars, which are durable and facilitate simple monitoring of changes in the soil layer. Each bar comprised a rod measuring 30~50 cm long and 1.5 cm in diameter, and the use of stainless steel afforded resistance to corrosion caused by sea breezes. Six measuring bars were installed in the soil layers of each of two islands, Dongdo and Seodo, and measurements were taken one to three times a year from 2014 to 2021. The field measurements indicate that soil was deposited on Dongdo but eroded on Seodo during the observation period. As the measuring bars on Dongdo were located in the central and lower parts of the island, the observed changes in the soil layer resulted mainly from sedimentation of material eroded by weathering or soil runoff from the upper part of the island. In contrast, the measurement locations on Seodo were located in the upper and central parts of the island, where soil erosion and runoff diminished the soil layer at the observation points.

Investigation of Plugging and Wastage of Narrow Sodium Channels by Sodium and Carbon Dioxide Interaction (소듐과 이산화탄소 반응에 의한 소듐유로막힘 및 재료손상 현상 연구)

  • Park, Sun Hee;Min, Jae Hong;Lee, Tae-Ho;Wi, Myung-Hwan
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.863-870
    • /
    • 2016
  • We investigated the physical/chemical phenomena that a slow loss of $CO_2$ inventory into sodium after the sodium-$CO_2$ boundary failure in printed circuit heat exchangers (PCHEs), which is considered for the supercritical $CO_2$ Brayton cycle power conversion system of a sodium-cooled fast reactor (SFR). The first phenomenon is plugging inside narrow sodium channels by micro cracks and the other one is damage propagation referred to as wastage combined with the corrosion/erosion effect. Experimental results of plugging shows that sodium flow immediately stopped as $CO_2$ was injected through the nozzle at $300{\sim}400^{\circ}C$ in 3 mmID sodium channels, whereas sodium flow stopped about 60 min after $CO_2$ injection in 5 mmID sodium channels. These results imply that if pressure boundary of sodium-$CO_2$ fails a narrow sodium channel would be plugged by reaction products in a short time whereas a relatively wider sodium channel would be plugged with higher concentration of reaction products. Wastage by the erosion effect of $CO_2$ (200~250 bar) hardly occurred regardless of the kinds of materials (stainless steel 316, Inconel 600, and 9Cr-1Mo steel), temperature ($400{\sim}500^{\circ}C$), or the diameter of the $CO_2$ nozzle (0.2~0.8 mm). Velocities at the $CO_2$ nozzle were specified as Mach 0.4~0.7. Our experimental results are expected to be used for determining the design parameters of PCHEs for their safeties.

An Experimental Study for Flexural Characteristic of Concrete Beam Reinforced with FRP Rebar under Static and Fatigue (FRP 보강근을 사용한 콘크리트 휨부재의 정적 및 피로특성에 대한 실험적 연구)

  • Sim, Jong-Sung;Park, Sung-Jae;Kang, Tae-Sung;Kwon, Dong-Wook;Lee, Ki-Hong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.313-316
    • /
    • 2008
  • Corrosion of steel in the reinforced concrete structures is one of the main reason of degradation. It causes that lifetime of structures is shortened and maintenance cost is increased. And it also causes degradation of structures like bridges which are under repeated load. So, many research have been performed about FRP rebar. But there are few research about FRP rebar under fatigue. This study is to examine flexural characteristic of concrete beam reinforced with FRP(CFRP, GFRP) rebar under static and fatigue for considering the application. The specimens that used in this study are designed by ACI 440.1R-06 and reinforced with CFRP(CR) or GFRP(GR) overly. In the result of static bending test, all specimens were failed at compression phase. In fatigue test, the fatigue stress level was 60%, 70% or 80% of the static bending strength. Most of the specimens seemed to be compressive failure, but CR-60 and CR-70 specimens were failed with rupturing of tension bar.

  • PDF