DOI QR코드

DOI QR Code

The Condition Evaluation of Mortar Parts of Stupa of State Preceptor Jigwang from Wonju Beopcheonsa Temple Site by Half Cell Potential Measurement - with Focus on the Mortar Parts the RoofStone -

반전위 측정을 통한 원주 법천사지 지광국사탑 모르타르 복원부위 상태평가 연구 - 옥개석 모르타르 복원부위를 중심으로 -

  • Lee, Tae Jong (Conservation Science Center, National Research Institute of Cultural Heritage) ;
  • Cho, Ha Jin (Conservation Science Center, National Research Institute of Cultural Heritage) ;
  • Park, Hee Jeong (Conservation Science Center, National Research Institute of Cultural Heritage) ;
  • Chae, Seung A (Conservation Science Center, National Research Institute of Cultural Heritage)
  • 이태종 (국립문화재연구소 문화재보존과학센터) ;
  • 조하진 (국립문화재연구소 문화재보존과학센터) ;
  • 박희정 (국립문화재연구소 문화재보존과학센터) ;
  • 채승아 (국립문화재연구소 문화재보존과학센터)
  • Received : 2018.10.10
  • Accepted : 2018.11.22
  • Published : 2018.12.20

Abstract

Stupa of State Preceptor Jigwang at Beopcheonsa temple site, Wonju, was conserved and restored in 1957. It was necessary to assess the degree of damage to the used mortar and to provide objective data on the necessity of its removal. Therefore, the HCP(half-cell potential) measurement used in concrete fields was applied. Multi-regression analysis of HCP data, following the rapid corrosion test of the roofstone mortar used by the rebar, resulted in a high correlation of HCP values(0.86), depending on the amount of corrosion and cover depth used for the steel bar. As a result, high correlation values(0.86) for the coefficients of determination were derived. The showed that the measurement of the wet conditions -431 to -663 mV on the roofstone indicated a corrosion damage rate of 90% or more after removal and restoration.

원주 법천사지 지광국사탑의 1957년 수리 복원에 사용된 모르타르의 손상정도를 평가하고 제거 필요성에 대한 객관적인 데이터를 제공하기 위해 콘크리트 분야에서 사용되는 반전위측정방법을 적용하였다. 철근이 사용된 옥개석 모르타르와 실내 실험체의 촉진부식시험 후 반전위 측정값에 대한 다중회귀분석 결과, 부식량과 피복두께에 따른 HCP 값의 결정계수는 0.86이상의 높은 상관식이 도출되었다. ASTM C876기준에 따르면 옥개석의 습윤상태 측정값 - 431~-663 mV는 철근의 부식손상 확률이 90%이상이기 때문에 손상된 모르타르를 제거한 후 신석재를 사용한 복원이 필요한 것으로 판단된다.

Keywords

References

  1. ASTM C876-09, 2009, Standard test method for corrosion potentials of uncoated reinforcing steel in concrete. 1-6.
  2. Cultural Heritage Administration, 2004, Meeting of the 5th department of architecture and cultural heritage committee. 29-36. (in Korean)
  3. Cultural Heritage Administration, 2018, Monthly cultural heritage love. 161, 28-29. (in Korean)
  4. Cultural Heritage Conservation Science Center, 2015, Report of precise nondestructive diagnosis for Buddhist Stupa of Priest Jigwang in Beopcheunsaji temple site at Wonju. Kongju National University Industry-University Cooperation Foundation, 1-302. (in Korean)
  5. Cultural Heritage Conservation Science Center, 2017, Report of conservation and restoration of State Preceptor Jigwang Stupa from Beopcheonsa temple site in Wonju. 1-198. (in Korean)
  6. Elsener, B., Andrade, C., Gulikers, J., Polder, R. and Raupach, M., 2003, Hall-cell potential measurements - potential mapping on reinforced concrete structures. Materials and Structures, 36(7), 461-471. https://doi.org/10.1007/BF02481526
  7. Kim, K.B., Park, K.T. and Kwon, S.J., 2013, Variation of half cell potential measurement in concrete with different properties and anti-corrosive condition. Journal of the Korea Institute for Structural Maintenance and Inspection, 17(6), 95-103. (in Korean with English abstract) https://doi.org/10.11112/jksmi.2013.17.6.095
  8. Kwon, S. J. and Song, H. W., 2010, Analysis of carbonation behavior in concrete using neural network algorithm and carbonation modeling. Cement and Concrete Research, 40(1), 119-127. (in Korean with English abstract) https://doi.org/10.1016/j.cemconres.2009.08.022
  9. National Museum of Korea, 1957, Report on the reconstruction of the stupa of state preceptor Jigwang from Wonju Beopcheonsa temple site. 1-56. (in Korean)
  10. Ryu, H.S., Park, J.S. and Kwon, S. J., 2017, Relationship between half cell potential and corrosion amount considering saturated cover depth and W/C ratios in cement mortar. Journal of the Korea Institute for Structural Maintenance and Inspection, 21(3), 19-26. (in Korean with English abstract) https://doi.org/10.11112/jksmi.2017.21.3.019
  11. So, H.S., 2006, Environmental influences and assessment of corrosion rate of reinforcing bars using the linear polarization resistance technique. Journal of Korea Architecture Institute, 22(2), 107-114. (in Korean with English abstract)
  12. Song, H.W., Lee, C.H. and Lee, K.C., 2009, A study on corrosion potential of cracked concrete beam according to corrosion resistance assessment. Journal of the Korea Institute for Structural Maintenance and Inspection, 13(1), 97-105. (in Korean with English abstract)