• Title/Summary/Keyword: corrosion monitoring system

Search Result 109, Processing Time 0.023 seconds

A Study on the Corrosion Monitoring of Multi-functional Sensors for Reinforced Concrete Structures: Part 1 (철근 콘크리트 구조물용 다기능 멀티센서의 부식 모니터링에 관한 연구: Part 1)

  • Jin, Chung-Kuk;Jeong, Jin-A;Kyoung, Eun-Jin
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.270-274
    • /
    • 2012
  • This study represents the result of corrosion monitoring on reinforced concrete specimens by means of multi-functional corrosion monitoring sensors. To confirm the effectiveness of the sensors, eight different kinds of condition were adopted. Test factors were corrosion potential, current, corrosion rate, resistivity, and temperature, which were monitored with the sensors. Through this study, judging corrosion of steel in concrete with single corrosion factor such as corrosion potential was difficult, because many other factors can have an influence on the reaction of corrosion. By using three different kinds of sensors, it could enhance the accuracy of corrosion monitoring.

The Development of Real-Time Wireless Remote Corrosion Monitoring System Using TRS(II) (TRS를 이용한 실시간 무선 원격 부식감시시스템 개발(II))

  • Bae, Jeong-Hyo;Kim, Dae-Kyeong;Ha, Tae-Hyun;Lee, Hyun-Goo;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.618-620
    • /
    • 1999
  • The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or collapse of bridge and building and so on. So, he has been spent the money and the time for corrosion monitoring and analysis of measuring data. Therefore, KERI(Korea Electrotechnology Research Institute) has developed the real-time wireless remote corrosion monitoring system using by TRS(Trunked Radio System). The results of development for corrosion monitoring system are described briefly. Especially, the interfacing technology between the server and rectifier introduced in this paper.

  • PDF

Field Testing Center Design of Cathodic Protection System for Maritime Metallic Structures (해양구조물 전기방식시스템 현장적용실험장 설계)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.633-636
    • /
    • 2003
  • Most of maritime metallic structures are adopted a CP(Cathodic Protection) System for protection of corrosion in advanced country. So, we had been developed a remote corrosion monitoring control system. And we want to know the characteristics of efficiency, reliability, durability and so on. On the view point of it, we have to test in real field. in terms of design, cathodic protection systems, corrosion monitoring systems and optimal corrosion control systems compare to general commercial products. So, these systems have being studied to improve their capability. In this paper, the result of field testing center design of intelligent cathodic protection system including anodes, a real-time wireless remote corrosion monitoring and corrosion control system are described in naval ports.

  • PDF

The Development of Remote Corrosion Monitoring and Control System for Oil Tank by using the High Efficiency CP Rectifier (고효율 전기 방식용 정류기를 이용한 유류탱크의 원 방식 제어 시스템 개발)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.249-252
    • /
    • 2002
  • Recently, the advanced countries are using the corrosion monitoring system in a chemical plant and an oil tank in order to protect the corrosion because it leads to a big accident, pollution of soil. and lose of money Generally. the owners of the facilities adopt CP(Cathodic Protection) systems to protect the corrosion also. However, a CP system for oil tank was not considered in Korea Moreover they didn't adopted a corrosion monitoring system. In this paper, we have been developed not only the remote automatic corrosion monitoring but also the remote corrosion control system using the high efficiency CP rectifier. This results should be used to operate the CP system effectively and economically. And also it will be possible to extend the expectation life of the Oil tanks.

  • PDF

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

Study on the Web-based Prediction System for Corrosion Monitoring and Anti-corrosion (부식감시 및 방식을 위한 웹기반 예측시스템에 관한 연구)

  • Park, Hyoung-Keun;Kim, Sun-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.784-789
    • /
    • 2012
  • In this paper, a number of anode and reference electrodes that are installed around the target anti-corrosion objects to monitor, appropriate to your situation of a fixed potential and polarization methods can be applied automatically in the system was developed. In particular, this system was configured with a remote electric anti-corrosion automatic control device that have automatically adjust function to uniformal anti-corrosion in all parts of target objects, a corrosion monitoring device to perform the function of corrosion potential detection and a web-based operating program to perform the function of real-time monitoring, control and prediction. Using this system, by preventing oxidative corrosion phenomena can maximize the life of the target anti-corrosion objects.

The Development of The Remote Real-Time Corrosion Monitoring and Control System Using by TRS for Maritime Metallic Structures (TRS를 이용한 해양구조물의 원격 실시간 부식감시 및 방식 제어시스템 개발)

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Sang-Bong;Jeong, Seong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.657-659
    • /
    • 2000
  • The importance of total management for maritime structures (Ports, Piers, docks. marine bridges, marine roads, submarine pipelines, etc.) is more and more increasing in these days. Especially, in spite of the marine structures are exposed at the various corrosion circumstances, there are not only a standard of Cathodic Protection System but also knowledge of importance for necessity of corrosion monitoring. Therefore, this paper presents the results of development for the Remote Real-Time Corrosion Monitoring and Control System Using by TRS on Maritime Metallic Structures which can be prevents a big accident by corrosion.

  • PDF

Water Quality Monitoring for Corrosion Control in Waterworks System (상수도관망 시스템의 부식제어를 위한 수질모니터링)

  • Lee, Hyun-Dong;Kwak, Phill-Jae;Lee, Ji-Eun;Kim, Yeong-Kwan;Han, Myung-Ho;Park, Young-Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.77-87
    • /
    • 2009
  • In existing systems, the best method inhibiting corrosion control in water distribution systems is to reduce water corrosiveness. Water corrosion can be decreased by controlling water quality through simple water treatment in treatment plants. On this research, we study the characteristics of tab water qualities in domestic areas, assessment of corrosive water quality and the method of water quality monitoring. This review presents the method of water quality monitoring which is the most applicable. Monitoring for corrosion control in waterworks system is the most proper method; It can prevent serious accidents economically and reduce civil appeals. Surely we should assess corrosive water quality in tab water, and introduce water treatment methods to control corrosive water quality before monitoring for corrosion. According to a lot of researches, it has been proved that simple water treatments can reduce the pipe corrosion. In this review we should indicate that we do not control of the corrosive water quality due to domestic conditions, we should monitor the water quality basically. Therefore, we recognize how the existing water quality can cause problems on pipeline corrosion, how to deal with it. Then it will be possible to apply water quality monitoring for corrosion control in water distribution system. Monitoring for corrosion control can be expressed by LI index, it is already known in literatures. This review presents more simple method than existing methods than existing ones we expect to apply these methods to SCADA in the future.

Development of Integrated Corrosion Monitoring and Control System (통합 부식 모니터링 및 통합 제어 시스템의 개발)

  • Yoo, Nam-Hyun;Kim, Young-Hun
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.8-14
    • /
    • 2013
  • Although there are various factors that threaten the security of ships, one of the most harmful is corrosion. It is not easy to find corroding areas and the status of corrosion, even though corrosion causes serious problems such as submergence and marine pollution as a result of leaking oil and polluted water. To monitor the corrosion of ships, non-destructive inspection, weight loss coupons, electrical resistance, linear polarization resistance, zero resistance ammeter, and electrochemical impedance spectroscopy have been developed. However, these methods require much time to detect corrosion, and most are not appropriate for real time monitoring. Coating, sacrificial anode, and impressed current cathodic protection (ICCP) methods have been developed to control corrosion. The ICCP and sacrificial anode methods are the most popular ways to prevent ship corrosion. However, ICCP is only appropriate for the outside of a ship and cannot be used for complex structures such as ballast tanks because these are composed of many separate chambers. Sacrificial anodes have to be replaced periodically. This paper proposes an integrated corrosion monitoring and control system (ICMCS) that can detect corrosion in real time and is appropriate for complex structures such as ballast tanks. Because the system uses titanium for an anode, exhausted anodes do not need to be replaced.

Performance indicator of the atmospheric corrosion monitor and concrete corrosion sensors in Kuwait field research station

  • Husain, A.;Al-Bahar, Suad Kh.;Salam, Safaa A. Abdul
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.981-994
    • /
    • 2016
  • Two field research stations based upon atmospheric corrosivity monitoring combined with reinforced concrete corrosion rate sensors have been established in Kuwait. This was established for the purpose of remote monitoring of building materials performance for concrete under Kuwait atmospheric environment. The two field research sites for concrete have been based upon an outcome from a research investigation intended for monitoring the atmospheric corrosivity from weathering station distributed in eight areas, and in different regions in Kuwait. Data on corrosivity measurements are essential for the development of specification of an optimized corrosion resistance system for reinforced concrete manufactured products. This study aims to optimize, characterize, and utilize long-term concrete structural health monitoring through on line corrosion measurement and to determine the feasibility and viability of the integrated anode ladder corrosion sensors embedded in concrete. The atmospheric corrosivity categories supported with GSM remote data acquisition system from eight corrosion monitoring stations at different regions in Kuwait are being classified according to standard ISO 9223. The two nominated field sites where based upon time of wetness and bimetallic corrosion rate from atmospheric data where metals and rebar's concrete are likely to be used. Eight concrete blocks with embeddable anodic ladder corrosion sensors were placed in the atmospheric zone adjacent to the sea shore at KISR site. The anodic ladder corrosion rate sensors for concrete were installed to provide an early warning system on prediction of the corrosion propagation and on developing new insights on the long-term durability performance and repair of concrete structures to lower labor cost. The results show the atmospheric corrosivity data of the environment and the feasibility of data retrieval of the corrosion potential of concrete from the embeddable sets of anodic ladder corrosion sensors.