• Title/Summary/Keyword: correlation distance

Search Result 1,229, Processing Time 0.033 seconds

A Study on the Relationship Analysis Model between Visibility and Evacuation Time by User's Movement in the Lower Floor of General Hospital (종합병원 저층부에서의 이용자 이동에 따른 가시성과 피난 시간의 상관관계 분석 모델에 관한 연구)

  • Jung, Gi Hyun;Kweon, Jihoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.11-21
    • /
    • 2019
  • The purpose of this study was to present an analysis model for finding the correlation between visibility and evacuation time as users move in the outpatient department of the general hospital. The spatial scope of the study was limited to the first floor and second floor which are used for the outpatient department. Traffic density in outpatient departments was surveyed on site. Based on the surveyed traffic density, the evacuation simulation model was established for calculating the escape route and evacuation time for an individual user. The traffic density of the outpatient department as per the evacuation time was also calculated. With using evacuation simulations, the flow of evacuees was calculated through the density of traffic over the time of evacuation. Visibility data were set in the simulation model for users' escape routes. A correlation analysis between the product of evacuation flow measure and visibility measure of the evacuation population and evacuation time was performed. The analysis result showed negative correlation within a specific distance range. This study presented an analysis model showing that the evacuation condition considering spatial visibility in the outpatient department of general hospital visibility was negatively related to the analyzed evacuation time at the design stage.

Analysis of Asian Dust Transportation Time and Wind Farm in Baengnyeongdo Island and the Metropolitan Area (백령도와 수도권의 황사 수송 시간과 바람장 분석)

  • Jo, Won Gi;Kang, Dong-hwan;Park, Gyeong-Deok;Yang, Minjune
    • Journal of Environmental Science International
    • /
    • v.31 no.6
    • /
    • pp.525-533
    • /
    • 2022
  • Baengnyeongdo, located within the Asian dust stream, is an ideal place to analyze Asian dust moving into the West Sea due to its low emission of artificial pollutants. Baengnyeongdo is being used to analyze the vertical distribution of dust from the lower atmosphere to the upper layer through remote observation. This study compared the ground concentration of dust between Baengnyeongdo and the metropolitan area, estimated the lag time of transport of Asian dust from Baengnyeongdo to the metropolitan area, and examined the homogeneity of upper winds using the rawinsonde method. The results showed that the cross correlation coefficient was higher and the lag time was shorter for each observation station when the distance from Baengnyeongdo was shorter. The upper wind at Baengnyeongdo is dominated by the west/northwest wind. It is the basis for the correlation of dust concentration between Baengnyeongdo and the metropolitan area located to the east. In the future, upper wind data and Asian dust concentration data over the West Sea and Baengnyeongdo are expected to contribute to research related to the movement and prediction of Asian dust and preparation for Asian dust in the metropolitan area.

Analysis of factors affecting vegetation cover for stabilization of granite weathered soil forest road cut slopes

  • Seong-Man Kim;Sung-Min Choi;Ye Jun Choe;Yun-Jin Shim;Joon-Woo Lee
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.861-871
    • /
    • 2022
  • This study was conducted to improve the stability of cut slopes of forest roads in granitic weathered soil areas. The study area is a national forest road (road length 28.48 km) in Pyeongchang-gun, Gangwon-do. After data collection, a statistical analysis was performed using IBM SPSS (Ver. 26.0). First, the correlation analysis showed that structure, slope position, soil erosion, slope, and aspect (N, S) were correlated with vegetation coverage (p < 0.05). Elapsed years, slope distance, and aspect (E, W) were found to have no correlation with vegetation coverage. (p > 0.05) Second, one-way ANOVA and Kruskal-Wallis test results showed that vegetation coverage was worse when the slope was located at the top or the middle of the slope than at the bottom of the slope. In addition, the site with sheathing and gabions showed good vegetation coverage when compared with the site without structures. In the case of soil erosion, areas with severe damage and moderate damage showed worse vegetation coverage. Therefore, it is necessary to strengthen the slope angle of the cut soil of the granitic weathered soil area from 1 : 0.5 - 1.2 to 1 : 0.8 - 1.5. In addition, structures such as sheathing and gabions should be installed on granitic weathered land.

Analysing Potential Improvement of Public Transit Services in OD Level Using Time-Distance Accessibility and Smartcard Traffic Volume (시간거리 접근성과 교통카드 기반 통행량을 이용한 OD별 잠재적 대중교통 서비스 개선량 분석)

  • YANG, Hyun-Jae;NAM, Hyun-Woo;JUN, Chul-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.2
    • /
    • pp.80-93
    • /
    • 2018
  • Public transit services are generally analyzed based on the correlation of demand and supply. The computation of supply uses accessibility while demand uses travel demands estimation based on residential population. However, the traditional demand estimation has a limitation in analysing in micro-scale compared to the smartcard data traffic. This study analyzed potential improvement of public transit services using smartcard traffic data. The supply of transportation was defined using time distance accessibility. Also, time loss was calculated in those origin destination(OD) pairs where time distance accessibilities are relatively low. The proposed method was applied at Seoul. The results showed that the areas where OD pairs need improvement include Seodaemun-gu, Guro-gu and Nowon-gu.

Behavior of Overtopping Flow of Caisson Breakwater with Dissipating Block: Regular Wave Conditions (소파블록피복 케이슨 방파제에서 월파의 거동분석: 규칙파 조건)

  • Ryu, Yong-Uk;Lee, Jong-In;Kim, Young-Taek
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.21 no.1
    • /
    • pp.54-62
    • /
    • 2009
  • The present study investigates the behaviour of overtopping flows falling on the leeside of a caisson breakwater with dissipating blocks through laboratory measurements. The falling overtopping flows in the leeside are expected to directly affect the leeside stability of the breakwater. This study focuses on not the resultant stability but the characteristic pattern of the overtopping flows depending on wave conditions through examining front velocity and plunging distance in the leeside. Regular waves were used to investigate the dependence of the overtopping flow pattern on wave conditions and a modified image velocimetry combining the shadowgraphy and cross-correlation method was employed for measurements of image and velocity. From the measurements, it is shown that the plunging distance and front velocity of the overtopping flow in the breakwater leeside increase as the wave period or height increases. From non-dimensional relationships between the variables, empirical formula for the velocity and overtopping distance are suggested.

Effect of soldering techniques and gapdistance on tensile strength of soldered Ni-Cr alloy joint

  • Lee, Sang-Yeob;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.117-121
    • /
    • 2010
  • PURPOSE. The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS. Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS. Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). CONCLUSION. There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

Changes in the Emotion by the Expressive Definition of Visual Contents (영상콘텐츠의 표현밀도에 따른 감정의 변화)

  • Kim, Se-Hwa
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.1
    • /
    • pp.192-201
    • /
    • 2010
  • This research deals with expressive definition of visual contents by using the distance between a subject and a screen resolution, and what changes affect the emotion of those looking at the expressive definition. A visual image captured from a HDTV screen was shown to the 61 students attending a university in the Busan area and SAM evaluation method was used to measure 3 different emotions such as pleasant, arousal, and dominance. While comparing different resolution, looking at high resolution contents rather than low resolution resulted in a direction of pleasant, arousal, and dominance. Also showing a different resolution than consistently showing the same resolution had a more volatile emotional effect. Aftermath multiple comparison resulted in a tendency for emotions to become unpleasant and un-arousal when high resolution contents were shown and then switched to a low resolution contents. There was no result of any significance in the control variables. Also on the aftermath multiple comparison on short, medium and long distance between the subject and the screen resolution, short distance had a bigger pleasant, arousal, and dominance emotional numbers than the rest. In a multiple variable verification result, a resolution and the distance of happiness and excitement showed a positive correlation.

Realtime Facial Expression Control of 3D Avatar by Isomap of Motion Data (모션 데이터에 Isomap을 사용한 3차원 아바타의 실시간 표정 제어)

  • Kim, Sung-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.9-16
    • /
    • 2007
  • This paper describe methodology that is distributed on 2-dimensional plane to much high-dimensional facial motion datas using Isomap algorithm, and user interface techniques to control facial expressions by selecting expressions while user navigates this space in real-time. Isomap algorithm is processed of three steps as follow; first define an adjacency expression of each expression data, and second, calculate manifold distance between each expressions and composing expression spaces. These facial spaces are created by calculating of the shortest distance(manifold distance) between two random expressions. We have taken a Floyd algorithm for it. Third, materialize multi-dimensional expression spaces using Multidimensional Scaling, and project two dimensions plane. The smallest adjacency distance to define adjacency expressions uses Pearson Correlation Coefficient. Users can control facial expressions of 3-dimensional avatar by using user interface while they navigates two dimension spaces by real-time.

Lyotropic Behaviors of a Phospholipid-based Lamella Liquid Crystalline Phase Hydrated by Propylene Glycol as a Polar Solvent: Correlation of DSPC vs PG Concentration

  • Jeong, Tae-Hwa;Oh, Seong-Geun
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.108-114
    • /
    • 2007
  • The lyotropic behaviors to form the structure of distearoylphosphatidylcholine (DSPC)-based liquid crystal (LC) hydrated by only propylene glycol (PG) without water were examined by differential scanning calorimetry (DSC), X-ray diffractions (XRD), polarized microscope (PM) and transmission electron microscope (TEM). By increasing the amount of PG instead of water, it showed the phase transition to be gradually changed from anisotropic structures to other structures more close to isotropic ones and their appearance to be changed from solid-like states to liquid-like ones with more fluidity. Below 50% w/w PG, the mixtures of DSPC and PG resulted in no direct observation of LC structure through PM because they were very close to solid-states. From 55% w/w to 90% w/w of PG, the dense lamella crystalline structures were observed through PM, and their thickness and area decreased as the content of PG increased. Measured by DSC with heating process, the main phase transition from α -lamella phase to isotropic phase appeared from 52.89 °C to 47.41 °C to show linearly decreasing behaviors because PG affects the hydrophobic region of DSPC-based lamella phase. The repeating distance of the lamella phase and the interlayer distance between bilayers were calculated with XRDs and the average number of bilayers related to the thickness in LC structure was approximately estimated by combining with TEM results. The WAXS and DSC measurements showed that all of PG molecules contributed to swelling both the lipid layer in the edge region of lamella phase close to phosphate groups and the interlayer between bilayers below 90% w/w of PG. The phase and thermal behaviors were found to depend on the amount of PG used by means of dissolving DSPC as a phospholipid and rearranging its structure. Instead of water, the inducement of PG as a polar solvent in solid-lamella phase is discussed in terms of the swelling effect of PG for DSPC-based lamella membrane.